SLIA-300

Highly Sensitive Silica Monitor SLIA-300

고감도 실리카 분석기

SLIA-300고감도 실리카 모니터 0.01 µg/L (0.01 ppb)의 극미량 감도로 초저밀도 실리카 측정이 가능합니다.

이온 교환 수지. 이 이온교환수지에서 용해된 실리카를 최대한 빨리 측정하여 생산 공정에서 중요한 초순수 수질을 제어할 수 있습니다.
HORIBA는 초저밀도 실리카의 고감도 측정을 가능하게 하는 'long light path length measurement cell'을 개발했으며 사용성을 향상시키기 위해 컴팩트한 데스크탑 모델을 채택했습니다.
자가 진단 기능 및 빠른 응답 처리와 같은 고감도 성능으로 반도체 생산에서 순수 공정에 대해 서포트합니다.

Segment: Semiconductor
Manufacturing Company: HORIBA Advanced Techno Co., Ltd.
  • High Sensitivity and High Reproducibility

A long light path of approx. 1 m is secured by applying fiber optic technologies. This realizes high sensitivity that responds to ultra-low density. This product ensures the reproducible accuracy of the full scale ±2% within the range from 0 to 2 µg/L during high-speed 5-minute measurement.

SLIA-300 - 0.01ug

  • Desktop Model Compact Design

The flexible structure of the "long light path length measurement cell" also realizes a revolutionary compact design. This desktop model is available for various installation conditions such as small spaces.   

SLIA-300 - desktop model

  • Reduced Consumption of Reagent to 1/5

To reduce the consumption of reagent to 1/5 of the previous amount, the reaction cell has been improved and separated from the measurement cell. Also, the measurement cell has been changed to a tube type. Employing the "long light path length measurement cell" can reduce the running cost for reagents drastically.

SLIA-300 - low running cists

  • Reduced Consumption of Reagent by More Than Half

Reduced the consumption of not only the reagent but also the sample water. By employing the "long light path length measurement cell," the consumption of expensive pure water (used as sample water) is reduced by 60%. The silica monitor from HORIBA Advanced Techno contributes to reduce the on-site costs.    

  • Self-Diagnosis Function That Monitors for Operation Errors

Performs self-diagnosis for operation errors such as sample water and/or reagent injection, calibration error, temperature monitoring in a cell, and light source error. When an error is found, a warning lamp is lit and a text message is displayed.

  • Automatic Calibration to Realize Superior Maintainability

Zero calibration is always performed automatically to check for transmitted light and to calibrate the turbidity.

  • Up to Six-Point Measurement Allowed (Optional)

Up to six measurement points can be set. A single unit can be used for multi-point measurement.

  • Semi-permanent Light Source Employed: No Replacement Necessary

A monochromatic semiconductor light source, which provides a steady light volume and long life, is employed. It can be used as semi-permanent light source.

 

Long Light Path Length Measurement Cell: Detects 0.01 µg/L at Minimum

The measurement cell has a double structure in which a light permeable fluorocarbon resin tube runs through a stainless steel pipe. The light coming in from one side of the pipe is repeatedly reflected in the pipe due to the difference of the refractive index between the fluorocarbon tube and the ambient air before reaching the other side.
This light transmission mechanism is an application of the optical fiber's high efficiency and low blockage principle, which realizes improved detection sensitivity and high reproducibility. (Patent pending)

SLIA-300 - Long Light Path Length Measurement Cell

This long light path length cell employs a flexible tube structure, enabling a small-footprint design. By storing the long cell of approx. 1 m in a desktop compact body, a small unit that is 1/8 the size of the previous model has been realized.
Also, the tube structure of the cell has a big advantage for reducing running costs: it reduces the consumption of color reagent and sample water to 1/5 and 1/2 of the previous amounts, respectively.

ModelSLIA-300
Measurement methodMolybdic blue absorptiometry
Measurement range0 to 2 / 0 to 20 µg/L, or 0 to 5 / 0 to 50 µg/L (please specify when placing an order)
Measurement time5 minutes
Measurement points1 to 6 points (please specify when placing an order)
Reproducibility±2% of full scale
Calibration functionStandard fluid calibration
Compensation functionBlank compensation
Metage line compensation (Specific to each line)
Reagent used· Reagent A: sulfuric acid + ammonium molybdate
· Reagent B: oxalic acid
· Reagent C: L (+) - ascorbic acid
Reagent replacement intervalOne week (according to the recommended period of our company)
Power100 to 240 V AC 50/60 Hz
Max. power consumptionApprox. 600 VA
Installation conditionIndoor, Ambient temperature 10 to 35°C, Humidity 85% or lower
Sample water condition· Water temperature: 15 to 35°C
· Supplied flow rate: 250 to 300 mL/min (must be adjustable)
· Pressure: 0.1 to 0.5 MPa
Outside dimensions580 (W) x 375 (H) x 500 (D) mm
WeightOne-point measurement: approx. 41 kg (plus 1 kg for an additional measurement point)
External I/ODensity output4 to 20 mA DC / 0 to 16 mA DC / 0 to 1 V DC (to be specified at order)
Contact output· Common to all lines:
During measurement, synchronous signals, alarms (batch), heaters, power off, calibration signals 1 and 2, density upper limit warning, or sample water off.
· Specific to each line:
Measurement range, density upper limit warning, or sample water off (the density limit warning or the sample water off batch or respective line alarm should be specified when placing an order. The alarm contents should be also selected when placing the order.)
Contact input· Common to all lines:Calibration start, measurement start, cost-efficient operation, line selection, measurement low range, measurement high range
Serial I/ORS-232C
Applicable standardCE mark, FCC Part 15
OptionSample water heating unit, standard fluid supply unit, reagent blending tools