Factor Deficient Plasmas

Factor Deficient Plasmas

Hemostasis Reagents

HORIBA offers a complete range of immunodepleted Factor Deficient Plasmas covers both the extrinsic and intrinsic coagulation cascade pathways. These lyophilized human plasmas contain less than 1% residual factor activity while maintaining normal levels of other coagulation factors. 

Extrinsic and common pathway (Factor II, V, VII, X)

Deficient plasmas used for quantitative determination of factor II, V, VII, X with prothrombin time (PT) thromboplastin time reagent and one-stage coagulation test in decalcified plasmas. The decreased level of factors in common and extrinsic pathway could be observed in the following cases:
• Congenital or acquired factor deficiency states
• During treatment with anticoagulants
• In case of vitamin K deficiency (reduced intake or metabolic disorder)
• Liver disease (cirrhosis, hepatitis)
• During factor “depletion” due to disseminated intravascular coagulopathy (DIC).

Intrinsic pathway (Factor VIII, IX, XI, XII)

Deficient plasmas used for quantitative determination of factor VIII, IX, XI, XII with activated partial thromboplastin time (APTT) reagent and one-stage coagulation test in decalcified plasmas. The decreased level of factors in common and intrinsic pathway could be observed in the following cases:
• Congenital or acquired factor deficiency states (Hemophilia A: factor VIII deficiency, Hemophilia B: factor IX deficiency)
• Liver disease
• Autoimmune hemophilia states

 

*This product may not be available in your country or region at this time. Please contact your HORIBA Medical sales representative or distributor for more information. 

Segment: Medical
Dział: Hemostasis

Factor Deficient Plasmas

 ReferenceProduct NameFormulationPackagingSystems
Extrinsic pathway deficient plasmas1300113497Factor ll deficient plasmaLyophilized5 x 1 mLYumizen G1550/G1550h/G1500/G1500h/G850/G850h/G800/G800h
1300113499Factor V deficient plasmaLyophilized5 x 1 mLYumizen G1550/G1550h/G1500/G1500h/G850/G850h/G800/G800h
1300113520Factor Vll deficient plasmaLyophilized5 x 1 mLYumizen G1550/G1550h/G1500/G1500h/G850/G850h/G800/G800h
1300113522Factor X deficient plasmaLyophilized5 x 1 mLYumizen G1550/G1550h/G1500/G1500h/G850/G850h/G800/G800h
Intrinsinc pathway deficient plasmas1300113523Factor Vlll deficient plasmaLyophilized5 x 1 mLYumizen G1550/G1550h/G1500/G1500h/G850/G850h/G800/G800h
1300113524Factor lX deficient plasmaLyophilized5 x 1 mLYumizen G1550/G1550h/G1500/G1500h/G850/G850h/G800/G800h
1300113525Factor Xl deficient plasmaLyophilized5 x 1 mLYumizen G1550/G1550h/G1500/G1500h/G850/G850h/G800/G800h
1300113526Factor Xll deficient plasmaLyophilized5 x 1 mLYumizen G1550/G1550h/G1500/G1500h/G850/G850h/G800/G800h

Controls & Calibrators

ReferenceProduct NameFormulationPackagingSystems
13000130704CONT l - ll (Controls)Lyophilized(10+10) x 1 mLYumizen G1550/G1550h/G1500/G1500h/G850/G850h/G800/G800h/G400/G200
13000130703CAL (Calibrators)Lyophilized12 x 1mLYumizen G1550/G1550h/G1500/G1500h/G850/G850h/G800/G800h/G400/G200

 

 