Nitrous Oxide Monitoring for Greenhouse Gas Reduction

Greenhouse gases (GHG), which are considered to be one of the causes of the global warming, include carbon dioxide (CO2), methane (CH4), nitrous oxide (N2O), and fluorinated gases.

In particular, various industries are required to reduce and manage the  N2O emissions, which impact on the warming the atmosphere is 298 times that of CO2.

For example, sewage treatment plants generate N2O during sludge incineration treatment and during wastewater treatment in raw-water tanks and sludge storage tanks. Meanwhile, industrial waste treatment plants and garbage disposal plants generate N2O during incineration. Although N2O reduction has become increasingly common by adoption  the latest equipment such as pyrolysis gasifying treatment, further reduction of N2O emissions is required through proactive monitoring.

  Sewage Treatment Facilities

   Waste Treatment Plants

        Chemical Plants

     Research & Development


Voice of Facility Management and Plant Manufacturers

  • Need to monitor N2O continuously and at high accuracy 24 hours a day, 365 days a year

 ► Sewage treatment facilities

     - Sludge incineration: high-temperature cyclone, exhaust gas from stack

     - Water discharge: raw-water tank, sludge storage tank

 ► Incineration facilities at industrial waste treatment plants and garbage disposal plants

      - Fluidized-bed-type incineration system

    ► Manufacturing facilities at chemical plants

         - Production of nitric acid from ammonia
 

Voice of R&D Managers

  • Setup of analyzer needs to be easy to operate for R&D of N2O
  • Need to be able to conduct N2O research and studies in the field and in the lab

 ► Various research and development departments


 

Solutions from HORIBA

Lineup of GHG (N2O, CH4, CO2) Analyzers by  Application

For On-site Continuous Monitoring

Highly accurate real-time monitoring of GHGs 24/7 even in harsh environment

Stack-Gas Analyzer
ENDA-5000 Series

  • Low downtime of analyzer
  • Simultaneous measurement of up to five components including GHGs

    (NOx, SO2, CO, CO2, O2, N2O, CH4)

  • Minimum range : 0-50 ppm
    Maximum range: 0-25 vol%

 

*Available ranges and combination of gases to be consulted. Customization on request.

Stack Gas Analysis System ENDA-5000

Stack Gas Analysis System ENDA-5000

For Speedy Measurement at Various Locations

Simultaneous measurement of three GHGs by a single portable unit

Portable Gas Analyzer
PG-344 for Carbon Neutral

  • Compact, lightweight and portable
  • On-site and lab measurement available
  • Simultaneous measurement of four components (N2O, CH4, CO2, O2)

  • Minimum range : 0-100ppm

   Maximum range: 0-25 vol%

*Refer to the PG-344 for Carbon Neutral brochure below for details of each gas range.

Portable Gas Analyzer PG-300

Portable Gas Analyzer PG-300

Portable Gas Analyzer PG-300

Portable Gas Analyzer PG-300

For Measurement at Lab

Quick set up of sampling system for R&D oriented GHGs monitoring

Multi-Component Gas Analyzer
VA-5000 Series

  • Wide measurement range
  • Measurement of up to four components including GHGs (CO, CO2, CH4, N2O, NO, SO2, NH3, NOx, O2)
  • Minimum range : 0-20ppm
    Maximum range: 0-100 vol%
     

*Available ranges and combination of gases to be consulted. Customization on request.

Multi-Component Gas Analyzer VA-5000 Series

Multi-Component Gas Analyzer VA-5000 Series


Example of Total Emission Control System

Total Emission Control by Combining with Stack Gas Analyzer

By combining stack gas emission analyzer and N2O analyzer, a single system can fully control exhaust gas by measuring multiple  gas components (NOx/SO2/CO/CO2/O2/N2O) at the same time.

Total Emission Control by Combining with Stack Gas Analyzer

Total Emission Control by Combining with Stack Gas Analyzer

Related Websites

Carbon Capture and Utilization

While contributing to reducing carbon, we propose a more efficient way of energy usage in various processes. Our technology in CCUS can effectively manage energy; as we provide recycled energy in processes high in demand; while saving energy from wastes and excess demand.

Related Brochures

Related Products

ENDA-5000 series
ENDA-5000 series

Stack Gas Analysis System

VA-5000 / VA-5000WM Series
VA-5000 / VA-5000WM Series

Multi-Component Gas Analyzer

PG-300 series
PG-300 series

Portable Gas Analyzer

Informationsanfrage

Sie haben Fragen oder Wünsche? Nutzen Sie dieses Formular, um mit unseren Spezialisten in Kontakt zu treten.

* Diese Felder sind Pflichtfelder.

Corporate