| Product name | Industrial 2-channel conductivity meter |
| Model | HE-960CW |
Measurement method | Electrode type (2-electrode method) |
| Sensor input | 2 channels (for concurrent measurement with sensors isolated each other) |
| Cell constant | 0.01/cm, 0.1/cm, or 1.0/cm |
Temperature sensor specifications | Platinum resistance 1000 Ω/0℃ |
| Measuring range | Cell constant (/cm) | 0.01 (ESD/ESL/ESH-001) | 0.1 (ESD/ESL/ESH/FS-01) | 1.0 (ESD/ESL/ESH-1) |
Conductivity range | (μS/cm) | 2.000/20.00 | 2.000/20.00/200.0/2000* | 200.0/2000 |
| (mS/m) | 0.2000/2.000 | 0.2000/2.000/20.00/200.0* | 20.00/200.0 |
TDS conversion | (mg/L) | 2.000/20.00 | 2.000/20.00/200.0/2000* | 200.0/2000 |
| *: Applicable for only sanitary sensor (FS-01 series) |
| Temperature | 0℃ to 100℃ |
| Desalination rate | 0.0% to 100.0% |
Conductivity difference | Depends on measurement range of sensor 2 (CH2). |
| Repeatability | Conductivity display | Within ±0.5% of the full scale (in equivalent input) 2000 μS/cm and 200.0 mS/m ranges of FS-01: Within ±2% of the full scale |
TDS conversion display | Within ±1.5% of the full scale (in equivalent input) |
| Linearity | Conductivity display | Within ±0.5% of the full scale (in equivalent input) 2000 μS/cm and 200.0 mS/m ranges of FS-01: Within ±2% of the full scale |
TDS conversion display | Within ±1.5% of the full scale (in equivalent input) |
Display/output range | Conductivity | Measurement range |
| Temperature | −30℃ to 160℃ |
| Desalination rate | 0% to 100% |
Conductivity difference | Measurement range of sensor 2 (CH2) |
Transmission output | Number of outputs: 4 4 mA to 20 mA DC/0 mA to 20 mA DC, input/output isolated type Maximum load resistance: 900 Ω Transmission output range: Freely selectable within the measurement range(Negative terminals of each transmission output channel are connected inside and thus have the same electric potential.) |
| Contact output | - Number of outputs: 4
- Alarm contact outputs (R1, R2, and R3)
Contact type: relay contact, SPST (1a) Contact rating: 240 V AC, 3 A and 30 V DC, 3 A (resistance load) Contact function: selectable from the upper/lower limit action (ON/OFF control), delay, and hysteresis. Output contents: selectable from the selected measurement, USP assessment,anomaly alarm and maintenance. - Alarm contact output (R4)
Contact type: relay contact, SPDT (1c) Contact rating: 240 V AC, 3 A and 30 V DC, 3 A (resistance load) Contact function: selectable from the upper/lower limit action (ON/OFF control), delay, and hysteresis. Output contents: selectable from the selected measurement, USP assessment,anomaly alarm and maintenance. (However, R1 and R2, and R3 and R4 share the common contacts respectively.) - Contact operation (operation between C and NO for R1 to R4)
When selected measurement, USP assessment, or maintenance is selected in output contents: Contact point becomes “CLOSE” at control operation and “OPEN” at normal state (including power shutdown). When anomaly alarm is selected in output contents: Contact point becomes “CLOSE” at normal state and “OPEN” at anomaly state (including power shutdown). (When between C and NC is used with R4, contact point becomes reverses state with that of between C and NO.) |
Communication output | RS-485 input/output |
Calibration function | Conductivity: Based on the specified compensation coefficient for cell constant (parameter input). Temperature: Calibrated by comparing with the reference thermometer. TDS: Conversion using a user-defined coefficient value (0.30 to 1.00). |
Transmission output hold feature | - Previous value hold
- Optional value hold
Selectable from the above (However, only the previous value hold is available in the maintenance mode.) |
Self-diagnosis function | - Sensor diagnosis
Short-circuit and disconnection of the temperature sensor - Out of the measurement range
- Converter error
|
Temperature compensation | - Temperature characteristic of NaCl (reference temperature: 5℃ to 95℃)
- Arbitrary temperature coefficient entry.
(reference temperature: 5℃ to 95℃: temperature coefficient: ±5%/℃) (In the deionized water area, however, the temperature compensation for deionized water is automatically performed in both NaCl and arbitrary temperature coefficient compensation settings.) - No temperature compensation
|
Temperaturecompensated range | 0℃ to 100℃ |
Ambient temperature | −5℃ to 55℃ |
| Relative humidity | 20% to 85% (without dew condensation) |
Storage temperature | −25℃ to 65℃ |
| Power supply | Rated voltage 100 V to 240 V AC, 50 Hz/60 Hz, 25 VA (maximum) |
| Structure | Indoor-use panel installation type Panel case: ABS, Terminal: PBT Panel: IP65 dust and water proof structure |
Protective structure | Panel: IP65 (IEC60529, JIS C0920) Rear case: IP20, Terminal:IP00 Class II device (IEC61010-1) Pollution level 2 (IEC61010-1) |
Conforming standards | CE Marking | EMC Directive: EN61326-1 Low Voltage Directive: EN61010-1 RoHS Directive: EN50581 |
| FCC Rule | FCC Part15 |
External dimensions | 96 (W) mm × 96 (H) mm × 115 (D) mm Case depth: approx. 105 mm (when panel-mounted) |
| Mass | Approx. 550 g |
Compatible sensors | Sensor type | Model | Cell constant (/cm) | Temperature coefficient of temperature sensor (ppm/℃) |
| Insert type | ESD/ESL series | 0.01, 0.1, 1.0 | 3750 |
| ESH series | 0.01, 0.1, 1.0 | 3850 |
| Sanitary insert type | ESD-01C-SN1.5 | 0.1 | 3750 |
| ESH-01C-SN1.5 | 0.1 | 3850 |
Sanitary flow-through type | FS-01C-SL series | 0.1 | 3750 |
| FS-01FC-SL series | 0.1 | 3850 |