HE-300R

Field-installation type electric resistivity meter (resistivity meter)

For measuring the electric resistivity of UPW (ultra-pure water).

Combined with the electric resistivity sensor (ERF series), it measures the electric resistivity and temperature of aqueous solutions. Suitable for measuring electric resistivity of UPW.

RESIST

Division: Process Water
Manufacturing Company: HORIBA Advanced Techno Co., Ltd.

Enables measurements with minimal error

Measurements are affected less by ambient temperature and sample temperature, enabling accurate measurements with less error.

We provide equipment and sensor calibration services

Temperature sensor offset calibration is offered as well as transmitter and sensor combination calibration services. *Option

Highly responsive temperature sensor

Helps to minimize fluctuations in measurement values due to delayed temperature compensation in the event of sudden changes in water temperature.

Product nameResistivity meter
ModelHE-300R
Sensors in
combination
2-electrode method resistivity sensor (ERF-001 Series) of cell constant 0.01/cm
Measuring rangeResistivityMΩ•cm0.000 to 2.0000.00 to 20.00 (*1)
kΩ•cm0.00 to 20.000.0 to 200.0 (*1)
Temperature0℃ to 100℃ (Display range: −10℃ to 110℃)
Display
resolution
ResistivityAs shown in the measuring table.
Temperature0.01℃
PerformanceResistivityRepeatabilityWithin ±0.1% of the full scale (response for equivalent input)
LinearityWithin ±0.5% of the full scale (response for equivalent input)
TemperatureRepeatability±0.1℃ (response for equivalent input)
Linearity±0.5℃ (response for equivalent input)
Transmission
output
Output type4 mA to 20 mA DC: input/output isolated type
Load resistanceMaximum: 600Ω  Case of 24 V DC power supply
Linearity±0.08 mA (output only)
Repeatability±0.02 mA (output only)
Output rangeResistivity: Free setting within a measuring range.
Occasional out for errorHold or burnout to either 3.8 mA or 21 mA
Transmission holdIn the maintenance mode, transmission signal is held at the latest value or preset value.
In the calibration mode, transmission signal can be alive or held.
Contact inputNumber of input1
Contact typeNo-voltage "a" contact for open collector
ConditionsON resistance: 40 Ω max.
Open voltage: 1.2 V DC
Short-circuit current: 21 mA max.
Contact functionExternal input for transmission holding.
Temperature
compensation
Applicable temperature
element
Platinum resistor: 1 kΩ (0℃)
Compensation method
  • Temperature characteristic of NaCl (reference temperature: 5℃ to 95℃)
  • Arbitrary temperature coefficient input (reference temperature: 5℃ to 95℃; temperature coefficient: +/−3%/℃)
  • No temperature compensation
    One of the three ways of compensation is selectable.
    (In the de-ionized water area, the temperature compensation for pure water is automatically performed in both NaCl and arbitrary temperature coefficient compensation settings.)
Temperature compensation
range
0℃ to 100℃ (However, the compensation calculation is extended lower than 0℃ or higher than 100℃.)
CalibrationResistivityBased on parameter input of coefficient for the sensor cell constant.
TemperatureComparison to the accurate thermometer
Both deviation and coefficient of RTD are taken into account for calibration.
Other functionUPW standard resistivity inputSelect one from the next.
182.3 kΩ•m (standard), 181.8 kΩ•m, 182.4 kΩ•m,
18.23 MΩ•cm (standard), 18.18 MΩ•cm, or 18.24 MΩ•cm
Clipping functionIf the measured value exceeds the user setting value for clipping, the measured data will be held at the clipping value.
Self-checkElectrode diagnostic errorTemperature sensor short-circuit, temperature sensor disconnection, and out of the temperature measurement range
Meter errorCPU, ADC, and memory errors
Operating
temperature
range
−20℃ to 60℃ (without freeze)
Operating
humidity range
Relative humidity: 5% to 90% (without condensation)
Storage
temperature
−25℃ to 65℃
Power supplyRated voltage24 V DC (operating voltage range: 21 V to 32 V DC)
Power consumption0.6W max.
Compatible
standards
CE markingEMC directive: EN61326-1
RoHS Directive: EN50581
 Immunity
Industrial
electromagnetic
environment
Electostatic dischargeIEC61000-4-2
Electromagnetic field of radiated radio frequencyIEC61000-4-3
Electric fast transient/burstIEC61000-4-4
SurgeIEC61000-4-5 (*3)
Conducted interference induced by radio frequencyIEC61000-4-6
Emission
ClassA
Radiated disturbanceCICPR 11 CLASS A
Noise terminal voltageCISPR 11 CLASS A
FCC RulesPart15 CLASS A
StructureInstallationOutdoor installation type
Installation methodMount on 50 A pole or wall
Protection codeIP65
Case materialAluminum alloy (coated with epoxy-denatured melamine resin)
Material of fittingsSUS304
Material of coverSUS304 stainless steel (coated with epoxy-denatured melamine resin)
Material of display
window
Polycarbonate
Display elementReflective monochrome LCD
External
dimensions
180 (W)  × 155 (H)  × 115 (D) mm (excluding mounting brackets)
MassMain body: Approx. 2.8 kg; cover and mounting brackets: Approx. 1 kg

Note

  • Note 1  : Without temperature compensation, 0.0-100.0 MΩ•cm(0-1000 kΩ•m) can be displayed.
  • Note 2  : The maximum load resistance that can be connected is decided depending on the powersupply voltage.

 

Relation between power supply voltage and load resistance

  • Note 3  : When the sensor cable, the transmission cable, or the contact input cable is extended by 30 m or more, the surge test under the EMC Directive for CE marking is not applied.
  • Note 4  : An arrester (spark over voltage: 400 V) is implemented for transmission output, contact input, and communication. However, use a most suitable surge absorption element on the connection lines in accordance with the ambient environment, the situation of equipment installed, and the externally connected equipment.