PPD Photon Counting Detector

Single photons detection with picosecond accuracy

Picosecond photon detection made easy.

The PPD Series is a range of miniaturized single-photon counting detectors containing all the electronics necessary to detect single photons with picosecond accuracy.

Segment: Scientific
Manufacturing Company: HORIBA Scientific

Each module contains a fast rise-time photomultiplier (PMT), GHz pre-amplifier, constant fraction discriminator (CFD) , regulated high voltage supply and in cooled detectors the thermoelectric cooler - all in one compact, fully integrated and factory optimized package.

The PPD series offers very high time resolution at an affordable price.  When used in time-resolved fluorescence applications, lifetimes as short as 20ps can be resolved using reconvolution.  Furthermore, unlike some more costly photon counting detectors, the PPD can also be used at very high counting rates without distortion. This makes the PPD not only an ideal time resolved detector, but also suitable for phosphorescence and general spectroscopic applications. Finally one photon counting detector that can be used for most applications without compromise.

The PPD's board is housed in a precision milled, nickel-plated casing to provide the highest level of electromagnetic shielding.  Optical coupling is via a convenient circular bayonet mount which at the same time provides a light-tight seal.

Simultaneous TTL-compatible and NIM-compatible signal outputs are provided, along with a Gate input that allows the HV to be disabled if required e.g. to protect the PMT when it is possibly going to be exposed to ambient light.

The TTL output may be connected to general purpose counter/timer apparatus, while the NIM output is compatible with TCSPC instrumentation.

Three models of PPD are available to suit different spectral ranges. (See the specification table.) The PPD-850 and PPD-900 versions have extended red sensitivity and feature integral thermoelectric cooling of the PMT to reduce the dark count rate.  Both these versions include the DPS-1 power supply module.  The uncooled PPD-650 version requires only 15V, so the DPS-1 is an optional power supply in this case.

The PPD is an ideal retrofit to existing fluorescence lifetime systems that still use side-window (e.g. R1527) and linear-focused (e.g. XP2020Q) photomultipliers, and is easer to use than SPADs (solid state), detectors because the active detection area is many thousand times larger.

Applications include:

  • Time-resolved fluorescence detection
  • Chemi-luminescence detection
  • Bioluminescence
  • Single molecule detection
  • Photon correlation spectroscopy
  • LIDAR
  • Particle sizing
  • Adaptive optics
  • Microscopy
  • General purpose photon counting and low light level detection
 PPD-650PPD-850PPD-900
Spectral response230-700nm230-850nm230-920nm
Peak wavelength350nm380nm490nm
Typical dark counts<80 cps<200 cps<3000 cps
Transit Time Spread<180 ps typical at 405nm
Thermoelectric coolingNoYesYes
DPS-1 includedOptionalYesYes
Dimensions77 x 107 x 48 mm
Weight0.6 kg
Power requirements+15V @ 330mADPS-1DPS-1

Specifications and appearance are subject to change without notice

PPD spectral response

Request for Information

Do you have any questions or requests? Use this form to contact our specialists.

* These fields are mandatory.

Related products

CFD-2G
CFD-2G

Amplifier-Discriminator

DAS6
DAS6

Decay Analysis Software

DeltaFlex
DeltaFlex

TCSPC/MCS Fluorescence Lifetime System

DeltaPro
DeltaPro

TCSPC Lifetime Fluorometer

Duetta
Duetta

Fluorescence and Absorbance Spectrometer

Fluorolog-QM
Fluorolog-QM

Modular Research Fluorometer for Lifetime and Steady State Measurements

FluoroMax Plus
FluoroMax Plus

Steady State and Lifetime Benchtop Spectrofluorometer

Hybrid Picosecond Photon Detector (HPPD) Series
Hybrid Picosecond Photon Detector (HPPD) Series

HORIBA’s latest development in TCSPC detector technology

Nanosizer
Nanosizer

For Single‐Walled Carbon Nanotube Excitation‐Emission Map Simulation and Analysis

PrintQuest
PrintQuest

Automated Fingerprint and Palmprint Identification - AFIS & APIS Systems

SpectraLED
SpectraLED

LED Phosphorescence Light Sources

Aqualog - Water Treatment Plant Analyzer
Aqualog - Water Treatment Plant Analyzer

Automated Organic Analysis & Early Warning Sentinel

Aqualog Datastream
Aqualog Datastream

For Instant Water Quality Reports

CFD-2G
CFD-2G

Amplifier-Discriminator

DAS6
DAS6

Decay Analysis Software

DeltaDiode
DeltaDiode

TCSPC Pulsed Sources

DeltaFlex
DeltaFlex

TCSPC/MCS Fluorescence Lifetime System

DeltaPro
DeltaPro

TCSPC Lifetime Fluorometer

Duetta
Duetta

Fluorescence and Absorbance Spectrometer

FLIMera
FLIMera

SPAD array imaging camera for dynamic FLIM studies at real time video rates

Fluorolog-QM
Fluorolog-QM

Modular Research Fluorometer for Lifetime and Steady State Measurements

FluoroMax Plus
FluoroMax Plus

Steady State and Lifetime Benchtop Spectrofluorometer

Hybrid Picosecond Photon Detector (HPPD) Series
Hybrid Picosecond Photon Detector (HPPD) Series

HORIBA’s latest development in TCSPC detector technology

Nanolog
Nanolog

Steady State and Lifetime Nanotechnology EEM Spectrofluorometer

Nanosizer
Nanosizer

For Single‐Walled Carbon Nanotube Excitation‐Emission Map Simulation and Analysis

QuantaPhi-2
QuantaPhi-2

PLQY Integrating Sphere

SpectraLED
SpectraLED

LED Phosphorescence Light Sources

Universal Fiber Coupling Solution
Universal Fiber Coupling Solution

Connect any of our steady state and hybrid fluorometers to virtually any upright or inverted microscope!

Corporate