0040N-10D

0040-10D ISFET pH electrode

ISFET pH Electrode

Perfect for measuring samples in shallow containers (e.g. petri dishes) and gelatinous materials (e.g. nutrient agar). For surface measurement of meat, paper, skin and cloth.

The Ion Sensitive Field Effect Transistor (ISFET) pH electrode has a semiconductor based sensor located less than 100 ยตm from the flat surface of the tip.

  • Measurement can be made from minute amount of moisture on solid sample surface
  • Pure water can be applied for samples with no moisture
  • Use of semiconductor sensor prevents damage such as crack or breakage
  • Waterproof
  • Comes with replacement sensor ISFET tip 0141N
Segment: Scientific
Division: Water Quality
Manufacturing Company: HORIBA Advanced Techno Co., Ltd.
  • pH measurement can be perfomed on a single drop of liquid sample or moist surface of solid or semi-solid sample.
  • Semiconductor based sensor eliminates concern that the electrode will get damaged. It will not crack or break like conventional glass electrodes.
  • Can be stored dry
  • Waterproof
  • Replaceable sensor (Model 0141N)
  • The diagonal cut structure helps to prevent bubbles from forming on the electrode tip. Reliable calibration and measurement in beakers.

 

Applications:

  • Environments where glass material cannot be used.
  • pH measurement of gelatinous materials in shallow containers (e.g., nutrient agar in petri dishes)
  • Surface measurement of skin, meat, cloth and paper.
  • If solid or semi-solid sample has minute amount of moisture, wet the surface with pure water prior to measurement.
  • Clean with neutral detergent and warm water after measuring oily samples.

Model0040N-10D
Sensing DeviceIon-sensitive field-effect transistor (ISFET)
Replacement Sensor 0141N
pH Range0 to 14
Usable Temperature Range Sensor: 0 to 60 ยฐC, Converter: 0 to 40 ยฐC
Storage Temperature Range0 to 40 ยฐC
Internal ElectrodeAg/AgCl
Reference Electrode Internal SolutionCarboxymethyl cellulose (CMC), glycerin, saturated KCl
Liquid Junction MaterialPorous sintered polyethylene
Sensor MaterialTantalum pentoxide, LCP, epoxy resin, polyethylene resin, gold, titanium
Height of Sensing Part1 mm (from the tip of the electrode)
Temperature SensorIntegrated
Power6V DC CR2032 x 2, Auto power off (1h)
LED IndicatorMeas LED (green blink while power on), Low batt LED (red blink when battery voltage is low)
ConnectorsBNC, phono jack
Electrode Length190 mm (excluding cable)
Cable Length1 m
Determination of pH as Quality Control Test in Culture Media
Determination of pH as Quality Control Test in Culture Media

์ œํ’ˆ ๋ฌธ์˜

HORIBA์ œํ’ˆ์˜ ์ž์„ธํ•œ ์ •๋ณด๋ฅผ ์›ํ•˜์‹œ๋ฉด, ์•„๋ž˜์˜ ์–‘์‹์— ๋‚ด์šฉ์„ ์ž…๋ ฅ์„ ๋ถ€ํƒ๋“œ๋ฆฝ๋‹ˆ๋‹ค.

* ๋Š” ํ•„์ˆ˜์ž…๋ ฅํ•ญ๋ชฉ์ž…๋‹ˆ๋‹ค.

Related products

Aqualog - Water Treatment Plant Analyzer
Aqualog - Water Treatment Plant Analyzer

Automated Organic Analysis & Early Warning Sentinel

HT-110
HT-110

์ด์œ ๊ธฐํƒ„์†Œ ๋ชจ๋‹ˆํ„ฐ

HU-200TB-IM
HU-200TB-IM

๊ณต์ •์šฉ ์‚ฝ์ž…ํ˜• SS/ํƒ๋„ ์ธก์ •๊ธฐ

LAQUA PH210
LAQUA PH210

Handheld pH/ORP/Temperature Meter

OCMA-500
OCMA-500

ํ์ˆ˜ ์˜ค์ผ ์ธก์ •๊ธฐ

OCMA-550
OCMA-550

์˜ค์ผ ๋†๋„ ์ธก์ •๊ธฐ

TPNA-500
TPNA-500

์ž๋™ ์ด์งˆ์†Œ/์ด์ธ ์ธก์ •๊ธฐ

TW-100
TW-100

์ž๋™ ์ˆ˜์งˆ ์ธก์ •์žฅ์น˜

Ultima Expert
Ultima Expert

๊ณ ํ•ด์ƒ๋„, ๊ณ ๊ฐ๋„, ๊ณ ์•ˆ์ •์„ฑ ICP-OES

WQMS
WQMS

์ˆ˜์งˆ ๋ชจ๋‹ˆํ„ฐ๋ง ์‹œ์Šคํ…œ (Water Quality Monitoring System)

CS-620F
CS-620F

๊ด‘์„ฌ์œ ํ˜• ๊ณ ์˜จ ์ธ์‚ฐ ๋†๋„ ๋ชจ๋‹ˆํ„ฐ

CS-900
CS-900

๋น„์ ‘์ด‰ ํ™”ํ•™๋ฌผ์งˆ ๋†๋„ ๋ชจ๋‹ˆํ„ฐ

HC-200F
HC-200F

ํ˜„์žฅ์„ค์น˜ํ˜• ๋ถˆ์†Œ์ด์˜จ์ธก์ •๊ธฐ(4-Wire Transmission)

HC-300F
HC-300F

ํ˜„์žฅ์„ค์น˜ํ˜• ๋ถˆ์†Œ์ด์˜จ์ธก์ •๊ธฐ(2-Wire Transmission)

HD-200
HD-200

ํ˜„์žฅ์„ค์น˜ํ˜• ์šฉ์กด์‚ฐ์†Œ์ธก์ •๊ธฐ(4-Wire Transmission), ๋ฉค๋ธŒ๋ ˆ์ธํ˜•)

HD-200FL (Four-Wire Transmission, ๊ด‘ํ•™์‹)
HD-200FL (Four-Wire Transmission, ๊ด‘ํ•™์‹)

ํ˜„์žฅ ์„ค์น˜ํ˜• ์šฉ์กด ์‚ฐ์†Œ ์ธก์ •๊ธฐ

HD-300
HD-300

ํ˜„์žฅ์„ค์น˜ํ˜• ์šฉ์กด์‚ฐ์†Œ์ธก์ •๊ธฐ(2-Wire Transmission), ๋ฉค๋ธŒ๋ ˆ์ธ ํ˜•)

HD-480
HD-480

์šฉ์กด์‚ฐ์†Œ์ธก์ •๊ธฐ(4-Wire Transmission), ๋ฉค๋ธŒ๋ ˆ์ธ ํ˜•)

HD-960L
HD-960L

์ €๋†๋„ ์šฉ์กด ์‚ฐ์†Œ ๋ชจ๋‹ˆํ„ฐ

HD-960LR
HD-960LR

์šฉ์กด ์‚ฐ์†Œ ๋†๋„ ๋ชจ๋‹ˆํ„ฐ

HE-200C
HE-200C

ํ˜„์žฅ์„ค์น˜ํ˜• ์ „๊ธฐ์ „๋„๋„๊ณ„(4-Wire Transmission, ์ €๋†๋„์šฉ)

HE-200H
HE-200H

ํ˜„์žฅ์„ค์น˜ํ˜• ์ „๊ธฐ์ „๋„๋„๊ณ„(4-Wire Transmission, ๊ณ ๋†๋„์šฉ)

HE-200R
HE-200R

ํ˜„์žฅ ์„ค์น˜ํ˜• ์ „๊ธฐ์ €ํ•ญ๊ณ„(4-Wire Transmission)

HE-300C
HE-300C

ํ˜„์žฅ ์„ค์น˜ํ˜• ์ „๊ธฐ์ „๋„๋„๊ณ„ (2-Wire Transmission, ์ €๋†๋„์šฉ)

HE-300C-IS ( ๋ฐฉํญํ˜• )
HE-300C-IS ( ๋ฐฉํญํ˜• )

๋ฐฉํญํ˜• ์„ค์น˜ ํƒ€์ž… COND meter ( Low concentrtion )

HE-300R
HE-300R

ํ˜„์žฅ ์„ค์น˜ํ˜• ์ „๊ธฐ์ €ํ•ญ๊ณ„(2-Wire Transmission)

HE-480C
HE-480C

ํŒจ๋„ ์žฅ์ฐฉํ˜• ์ „๋„๋„๊ณ„(4-Wire Transmission, ์ €๋†๋„์šฉ)

HE-480C-GC
HE-480C-GC

์นด๋ณธ ์„ผ์„œ ์ „๋„๋„๊ณ„ (์ €๋†๋„ํ˜•)

HE-480H
HE-480H

ํŒจ๋„ ์žฅ์ฐฉํ˜• ์ „๋„๋„๊ณ„(4-Wire Transmission,์ €๋†๋„์šฉ)

HE-480H-DC24V
HE-480H-DC24V

ํŒ๋„ฌ ์žฅ์ฐฉํ˜• ์ „๋„๋„๊ณ„(4-wire Transmitter , ๊ณ ์ „๋„๋„์šฉ)

HE-480R
HE-480R

ํŒจ๋„ ์žฅ์ฐฉํ˜• ์ €ํ•ญ๊ณ„(4-Wire Transmission)

HE-960CA
HE-960CA

๊ตฌ์—ฐ์‚ฐ ๋ชจ๋‹ˆํ„ฐ

HE-960CW
HE-960CW

ํŒจ๋„ ์žฅ์ฐฉํ˜• ์ „๋„๋„๊ณ„(4-Wire Transmission, 2์ฑ„๋„)

HE-960H-KOH
HE-960H-KOH

KOH ๋ชจ๋‹ˆํ„ฐ

HE-960H-TM-S
HE-960H-TM-S

๊ณ ์ •๋ฐ€ TMAH ๋†๋„ ๋ชจ๋‹ˆํ„ฐ

HE-960HC
HE-960HC

์นด๋ณธ ์„ผ์„œ ์ „๋„๋„๊ณ„ (๊ณ ๋†๋„ํ˜•)

HE-960HI
HE-960HI

ํŒจ๋„ ์žฅ์ฐฉํ˜• ์ „๋„๋„๊ณ„(4-Wire Transmission, ๊ด‘์—ญ์šฉ)

HE-960LC
HE-960LC

์นด๋ณธ ์„ผ์„œ ์ „๋„๋„๊ณ„

HE-960LF / FS-09F-1/2
HE-960LF / FS-09F-1/2

ํ‰ํƒ„ ์นด๋ณธ ์„ผ์„œ ์ „๋„๋„๊ณ„

HE-960RW
HE-960RW

ํŒจ๋„ ์žฅ์ฐฉํ˜• ์ €ํ•ญ๊ณ„(4-Wire Transmission, 2์ฑ„๋„)

HE-960RW-GC(W)
HE-960RW-GC(W)

2-์ฑ„๋„ ์ €ํ•ญ๋ฅ ๊ณ„

HO-480
HO-480

ํŒจ๋„ ์žฅ์ฐฉํ˜• ORP ๋ฏธํ„ฐ (4-Wire Transmission)

HP-200 (Four-Wire Transmission)
HP-200 (Four-Wire Transmission)

ํ˜„์žฅ ์„ค์น˜ํ˜• pH Meter

HP-300
HP-300

ํ˜„์žฅ ์„ค์น˜ํ˜• pH๋ฏธํ„ฐ (2-Wire Transmission)

HP-480
HP-480

ํŒจ๋„ ์žฅ์ฐฉํ˜• pH๋ฏธํ„ฐ (4-Wire Transmission)

HP-480PL
HP-480PL

ํŒจ๋„ ์žฅ์ฐฉํ˜• pH ๋ฏธํ„ฐ(4-Wire Transmission, ํŽ„์Šค ๋น„๋ก€ ์ œ์–ด)

HP-480TP
HP-480TP

ํŒจ๋„ ์žฅ์ฐฉํ˜• pH ๋ฏธํ„ฐ(4-Wire Transmission, ์‚ฐ์—…์šฉ ์‹œ๋ถ„ํ•  ๋น„๋ก€์ œ์–ด)

HP-960FTP
HP-960FTP

ํŒจ๋„ ์žฅ์ฐฉํ˜• pH ๋ฏธํ„ฐ(4-Wire Transmission, 4 ํฌ์ธํŠธ ์•Œ๋žŒ, ์‹œ๋ถ„ํ•  ๋น„๋ก€ ์ œ์–ด)

HR-200
HR-200

ํ˜„์žฅ ์„ค์น˜ํ˜• ์ž”๋ฅ˜์—ผ์†Œ ์ธก์ •๊ธฐ (4-Wire Transmission, Water flow beads)

HR-200RT
HR-200RT

ํ˜„์žฅ ์„ค์น˜ํ˜• ์ž”๋ฅ˜ ์—ผ์†Œ ์ธก์ •๊ธฐ (4-Wire Transmission, Rotating Type)

HR-480
HR-480

์ž”๋ฅ˜ ์—ผ์†Œ ์ธก์ •๊ธฐ (4-Wire Transmission)

LAQUA PH210
LAQUA PH210

Handheld pH/ORP/Temperature Meter

TW-100
TW-100

์ž๋™ ์ˆ˜์งˆ ์ธก์ •์žฅ์น˜

TW-150
TW-150

Online Water Quality Monitor (๊ณต์ • ์ˆ˜์งˆ ์ธก์ • ์‹œ์Šคํ…œ)

U-50 Series
U-50 Series

๋‹คํ•ญ๋ชฉ ์ˆ˜์งˆ ์ธก์ •๊ธฐ

UP-100
UP-100

๋งˆ์ดํฌ๋กœ ๋ณผ๋ฅจ pH ๋ชจ๋‹ˆํ„ฐ

HC-200F
HC-200F

ํ˜„์žฅ์„ค์น˜ํ˜• ๋ถˆ์†Œ์ด์˜จ์ธก์ •๊ธฐ(4-Wire Transmission)

HC-300F
HC-300F

ํ˜„์žฅ์„ค์น˜ํ˜• ๋ถˆ์†Œ์ด์˜จ์ธก์ •๊ธฐ(2-Wire Transmission)

HP-200 (Four-Wire Transmission)
HP-200 (Four-Wire Transmission)

ํ˜„์žฅ ์„ค์น˜ํ˜• pH Meter

HP-300
HP-300

ํ˜„์žฅ ์„ค์น˜ํ˜• pH๋ฏธํ„ฐ (2-Wire Transmission)

HP-480
HP-480

ํŒจ๋„ ์žฅ์ฐฉํ˜• pH๋ฏธํ„ฐ (4-Wire Transmission)

HP-480PL
HP-480PL

ํŒจ๋„ ์žฅ์ฐฉํ˜• pH ๋ฏธํ„ฐ(4-Wire Transmission, ํŽ„์Šค ๋น„๋ก€ ์ œ์–ด)

HP-480TP
HP-480TP

ํŒจ๋„ ์žฅ์ฐฉํ˜• pH ๋ฏธํ„ฐ(4-Wire Transmission, ์‚ฐ์—…์šฉ ์‹œ๋ถ„ํ•  ๋น„๋ก€์ œ์–ด)

HP-960FTP
HP-960FTP

ํŒจ๋„ ์žฅ์ฐฉํ˜• pH ๋ฏธํ„ฐ(4-Wire Transmission, 4 ํฌ์ธํŠธ ์•Œ๋žŒ, ์‹œ๋ถ„ํ•  ๋น„๋ก€ ์ œ์–ด)

LAQUA PH210
LAQUA PH210

Handheld pH/ORP/Temperature Meter

T1 - TOCADERO Series
T1 - TOCADERO Series

์˜จ๋ผ์ธ TOC ๋ถ„์„๊ธฐ

TW-100
TW-100

์ž๋™ ์ˆ˜์งˆ ์ธก์ •์žฅ์น˜

TW-150
TW-150

Online Water Quality Monitor (๊ณต์ • ์ˆ˜์งˆ ์ธก์ • ์‹œ์Šคํ…œ)

U-50 Series
U-50 Series

๋‹คํ•ญ๋ชฉ ์ˆ˜์งˆ ์ธก์ •๊ธฐ

UP-100
UP-100

๋งˆ์ดํฌ๋กœ ๋ณผ๋ฅจ pH ๋ชจ๋‹ˆํ„ฐ

Water & Liquid Corporate