APDA-372

Ambient Dust Monitor

The APDA-372 Ambient Dust Monitor is designed for indoor and outdoor air quality monitoring and provides continuous, simultaneous real-time measurements of PM1, PM2.5, respirable fractions (PM4), thoracic fractions (PM10), inhalable fractions (TSP), particle number concentration and, upon request, particle size distribution in 32 size classes per decade within the particle size range of 0.18–18 µm. The APDA-372 uses the QAL1 approved (EN16450) measurement technology of optical light scattering and is equipped with a white LED light source offering highly stable output and a long service life. An integrated filter holder for 47 mm or 50 mm absolute filters enables on-site gravimetric correlation and subsequent aerosol composition analysis. The system can also be connected to an isokinetic sampling probe for emission measurements in exhaust air ducts with a volume flow of 4.8 L/min. In addition, the APDA-372 includes sensors for temperature, atmospheric pressure and relative humidity monitoring.

Dział: Ambient
Firma produkcyjna : HORIBA Europe GmbH
Base product: AP-370 Series
  • Continuous and simultaneous real-time measurement of multiple PM values
  • Additional information based on particle number concentration
  • Adjustable time resolution from > 1 s to 24 h
  • Light source: LED with high stability and long lifetime
  • Long service life
  • Low maintenance; calibration can be verified on site
  • Intuitive and easy to operate
  • Reliable operation
  • No radioactive material
  • No consumables
  • Reduces your operating expenses

 

 

InterfacesUSB, ethernet, RS232/485, Wi-Fi
Measurement Range (Size)0.18–18 µm
Measuring Principleoptical light scattering
Measurement Range0 - 20,000 particles/cm3
Time Resolution1 s–24 h
Volume Flow4,8 L/min (0.3 m3/h)
Data Acquisitiondigital, 20 MHz processor, 256 raw data channels
Light SourceLED
Power Consumption60 W, max. 200 W
User Iterface7-inch touchscreen, 800 × 480 pixels
Power Supply115–230 V, 50–60 Hz
Housingtable housing, optionally with mounting brackets for rack mounting
Dimensions180.5 × 450 × 320 mm, 19-inch compatible, 4 HE, 84 TE
Weight9.3 kg
Operating SystemWindows Embedded
Data Logger Storage4 GB
Measurement Range (Mass)0–10,000 µg/m3

Wniosek o udzielenie informacji

Masz pytania lub prośby? Skorzystaj z tego formularza, aby skontaktować się z naszymi specjalistami.

* Te pola są obowiązkowe.

Related products

AP-370 Series
AP-370 Series

Air Pollution Monitor

AQMS
AQMS

Ambient Air Quality Monitoring System

H-1 Series
H-1 Series

Field-installation type water quality measuring instruments

MESA-50
MESA-50

X-Ray Fluorescence Analyzer

MESA-50K
MESA-50K

X-Ray Fluorescence Analyzer

MEXA-2000SPCS series
MEXA-2000SPCS series

Solid Particle Counting System

OBS-ONE PM unit
OBS-ONE PM unit

On-board Emissions Measurement System

TFH-01/47
TFH-01/47

PTFE Filter/TFH membrane

XGT-9000
XGT-9000

X-ray Analytical Microscope (Micro-XRF)

XGT-9000SL
XGT-9000SL

X-ray Analytical Microscope
with a Super Large Chamber

Partica
Partica

Laser Diffraction and Dynamic Imaging Particle Size and Shape Analyzer

Partica LA-960V2
Partica LA-960V2

Laser Scattering Particle Size Distribution Analyzer

Partica mini LA-350
Partica mini LA-350

Laser Scattering Particle Size Distribution Analyzer

PD10
PD10

Reticle / Mask Particle Detection System

PD10-EX
PD10-EX

Reticle / Mask Particle Detection System

Corporate