Plant sap testing can help growers achieve the optimum fertilization of vegetable crops. Analyzing fresh plant petiole sap for N and K concentrations using LAQUAtwin nitrate and potassium pocket meters is a quick procedure to determine the N and K levels in plants. The results can be used in guiding N and K applications.
Soil and plant tissue testing is a valuable tool for determining the fertilizer needs and maximizing the fertilizer efficiency. Soil test is especially useful early in the growing season when plants are too small to collect tissue samples. Plant tissue test for nitrogen (N) and potassium (K) levels during the growing season provides information for diagnosing problems. It is preferred than soil test as the results of which can change quickly by rain or irrigation.
Plant sap testing offers advantages over the conventional dry tissue testing being carried out in laboratories. Aside from the lower cost it requires, plant sap testing can be easily done in the field and the results can be obtained quickly which is important in making fertilization decisions.
Vegetable growers, consultants, and fertilizer companies can use the LAQUAtwin NO3-11 or NO3-11C nitrate pocket meters and LAQUAtwin K-11 potassium pocket meter in the field to help manage N and K fertilizer. These meters are waterproof and equipped with built-in thermistor that detects the sample temperature and replaceable sensor with flat membrane that accepts as little as 0.3 ml sample (0.05 ml with sampling sheet B). They can measure plant sap in just a few seconds and display ion concentration reading expressed in either mg/L or ppm unit. The LAQUAtwin NO3-11 and NO3-11C nitrate pocket meters can measure nitrate ion (NO3-) and nitrate-nitrogen (NO3-N).
Prior to sample measurement, calibrate the meters using the standard solutions included in their kits or prepare two standard solutions having concentrations that are ten-fold apart.
Samples should be read within the calibrated range of the meters. Readings outside the calibrated range should be considered inaccurate. Dilute the sap with deionized or distilled water if the reading is above the calibrated range and take the dilution factor into account when calculating the original sap concentration.
When the LAQUAtwin pocket meters are used in the field, it is recommended that they are operated under a shade and recalibrated frequently throughout the day as they are sensitive to temperature changes. It is best to collect petioles from the field and analyze them with the meters indoor. Refer to Technical Tip: LAQUAtwin Ion Sensor Maintenance Procedures for conditioning, cleaning, and storing the meters.
The nitrate level in plant can vary throughout the day. To obtain consistent test results, reasonable standardization of time, temperature, and weather conditions under which sampling is carried out will help.
1. Collect the petioles (leaf stems) of about 20 most-recently-matured leaves—those leaves that have reached maximum size and have changed from a juvenile light green color to a dark green color. Refer to Figure 1 to help you identify petioles of some vegetable crops. There are exceptions however—for example, the roots of onions are used to determine the nitrate levels. Refer to Application Note: Rapid In-Field Determination of Nitrogen in Onions.
2. Chop and mix the petioles. Take a subsample of chopped petioles for crushing.
3. Squeeze the sap from petioles using a garlic press, lemon press, or hydraulic sap press.
4. Measure the fresh sap using the LAQUAtwin pocket meters within 1-2 minutes of pressing.
5. Record the readings.
Figure 1: Leaves and petioles of some vegetable crops
Source: University of Florida - Plant Petiole Sap-Testing for Vegetable Crops
Over the growing season, vegetable crops differ widely in their nutrient needs and patterns of uptake. With regular plant sap testing and good record keeping, the trend of N and K concentrations can be followed over the season to gain insight on the nitrogen and potassium dynamics of the crop.
It is important to note the plant growth stage at sampling to know what sufficiency standard to apply. There are guidelines for various crops at various growth stages developed and published by universities and research institutes based on their research and field experience. Tables 1 and 2 contain ranges that are suggested critical values.
Table 1. Guidelines for plant leaf petiole fresh sap nitrate-nitrogen- and potassium-testing
Source: University of Florida - Plant Petiole Sap-Testing for Vegetable Crops
Table 2: Guidelines for fresh petiole sap nitrate-nitrogen
Source: California Department Food of Food and Agriculture - Guide to Nitrogen Quick-Tests for Vegetables with the Cardy Nitrate Meter
Revision 0, 14 May 2020
Pocket Water Quality Meters
Pocket Water Quality Meters
Masz pytania lub prośby? Skorzystaj z tego formularza, aby skontaktować się z naszymi specjalistami.
HORIBA Advanced Techno, Co., Ltd.
31, Miyanonishi-cho, Kisshoin
Minami-ku Kyoto 601-8306 Japan
Tel: +(81) 75 321 7184
Fax: +(81) 75 321 7291
HORIBA Instruments (Singapore) Pte Ltd.
83 Science Park Drive, #02-02A,
The Curie 118258 Singapore
Tel: +65 6 908 9660
Fax: +65 6 745 8155
Mail: laqua(at)horiba.com
HORIBA UK Limited Northampton Office
Kyoto Close,Summerhouse Road,
Moulton Park
Northampton NN3 6FL UK
Tel: +(44) 1604 542 600
Fax: +(44) 1604 542 699
Mail: waterquality(at)horiba.com
HORIBA Instruments Incorporated Head Office
9755 Research Drive
Irvine California 92618 USA
Tel: +1 800 446 7422
Fax: +1 949 468 1790
Mail: labinfo(at)horiba.com
You might also like to know...