HE-300C

Field-installation type electrical conductivity meter (conductivity meter)

For measurements in pure water, boiler water, and pharmaceutical manufacturing processes

Combined with electrical conductivity sensors (ESH/FS series) to measure electrical conductivity and temperature of water samples. Suitable for measurement of pure water and boiler water. A lineup of sensors for pharmaceutical manufacturing processes that comply with the pharmacopoeias (USP, EP, JP) of various countries are also offered.

COND

Подразделение: Process Water
Производитель: HORIBA Advanced Techno Co., Ltd.

Diverse lineup of sensors available

Sensors that are tailored to match the sample characteristics and applications are proposed.

Highly robust

Required accessories and wiring for installation possess the ruggedness appropriate for industrial applications, ensuring they can withstand harsh environmental conditions.

Product nameConductivity meter
ModelHE-300C
Sensors in combination2-electrode method conductivity sensor
ESH and FS Series sensor of cell constant 0.01/cm, 0.1/cm, or 1.0/cm
Measurable
range
(*Note 1)
Cell constant (/cm)0.01
(ESH-001)
0.1
(ESH/FS-01)
1.0
(ESH-1)
 Unit
ConductivityμS/cm0.000 to 2.000
0.00 to 10.00
0.000 to 2.000
0.00 to 20.00
0.0 to 100.0
0.0 to 200.0
0 to 1000
mS/m0.0000 to 0.2000
0.000 to 1.000
0.0000 to 0.2000
0.000 to 2.000
0.00 to 10.00
0.00 to 20.00
0.0 to 100.0
TDS
conversion
mg/L0.00 to 2.00
0.0 to 10.0
0.00 to 2.00
0.0 to 20.0
0 to 100
0 to 200
0 to 1000
Temperature0 to 100 (display range: −10℃ to 160℃)
Display
resolution
Conductivity
/ TDS conversion
As shown in the measuring table.
Temperature0.01℃
PerformanceConductivityRepeatabilityWithin ±0.5% of the full scale (response for equivalent input)
Within ±5% of the full scale in the range of 2000 μS/cm or 200 mS/m for FS-01 sensor
LinearityWithin ±0.5% of the full scale (response for equivalent input)
Within ±5% of the full scale in the range of 2000 μS/cm or 200 mS/m for FS-01 sensor
TDS conversionRepeatabilityWithin ±1.5% of full-scale value (response for equivalent input)
LinearityWithin ±1.5% of full-scale value (response for equivalent input)
TemperatureRepeatability±0.1℃(response for equivalent input)
Linearity±0.5℃(response for equivalent input)
Transmission
output
Output type4 mA to 20 mA DC input/output insulation type (two-wire transmission type)
Load resistanceMaximum: 600 Ω. Case of 24 V DC power supply (*Note 3)
LinearityWithin ±0.08 mA (output only)
RepeatabilityWithin ±0.02 mA (output only)
Output rangeConductivity: Free setting within a measuring range.
Occasional out for errorHold or burnout to either 3.8 mA or 21 mA
Transmission holdIn the maintenance mode, transmission signal is held at the latest value or preset value.
In the calibration mode, transmission signal can be alive or held.
Contact
input
Number of input points1
Contact typeNo-voltage a-contact
ConditionsON resistance: 40 Ω max.
Open voltage: 1.2 VDC
Short-circuit current: 21 mA DC max.
Contact functionExternal input for transmission holding.
Temperature
compensation
Temperature elementPlatinum resistor: 1 kΩ (0℃)
Temperature compensation
  • Temperature characteristic of NaCl (reference temperature: 5℃ to 95℃)
  • Arbitrary temperature coefficient input (reference temperature: 5℃ to 95℃; temperature coefficient: ±3%/℃)
  • No temperature compensation
    One of the three ways of compensation is selectable.
    (In the de-ionized water area, the temperature compensation for pure water is automatically performed in both NaCl and arbitrary temperature coefficient compensation settings.)
Temperature compensation
range
0℃ to 100℃ (However, the compensation calculation is extended lower than 0℃ or higher than 100℃.)
Temperature calibration1 point calibration comparing to reference thermometer
CalibrationConductivityBased on parameter input of coefficient for the sensor cell constant.
TDS conversionConversion by user-defined coefficient value
(TDS calculation is 0.30 to 1.00 times of sample conductivity by μS/cm.)
Self-checkSensor diagnosis errorTemperature sensor short-circuit, temperature sensor disconnection,
and out of the temperature measurement range
Meter errorCPU error, ADC error, and memory error
Operating temperature range−20℃ to 60℃ (without freeze)
Operating humidity rangeRelative humidity: 5% to 90% (without condensation)
Storage temperature−25℃ to 65℃
Power
supply
Rated voltage24 V DC (operating voltage range: 21 V to 32 V DC) (*Note 3)
Power consumption0.6 W max.
Compatible
standards
CE markingEMC directive: EN61326-1
RoHS Directive: EN50581
 Immunity
Industrial
electromagnetic
environment
Electostatic dischargeIEC61000-4-2
Electromagnetic field of radiated radio frequencyIEC61000-4-3
Electric fast transient/burstIEC61000-4-4
SurgeIEC61000-4-5
(*Note 2)
Conducted interference induced by radio frequencyIEC61000-4-6
Emission
Class A
Radiated disturbanceCICPR 11 CLASS A
Noise terminal voltageCISPR 11 CLASS A
FCC RulesPart15 CLASS A
StructureInstallationOutdoor installation type
Installation method50 Mount on 50 A pole or wall
Protection codeIP65
Case materialAluminum alloy (coated with epoxy-denatured melamine resin)
Material of fittingsSUS304
Material of hoodSUS 304 stainless steel (coated with epoxy-denatured melamine resin)
Material of windowPolycarbonate
Display elementReflective monochrome LCD
External dimensions180 (W) × 155 (H) × 115 (D) mm (excluding mounting brackets)
MassMain body: Approx. 2.8 kg; cover and mounting brackets: Approx. 1 kg

Note

  • Note 1: Only the sanitary sensor (FS-01 series) is applied.
  • Note 2: Conductivity measurement and TDS conversion measurement cannot be selected at the same time.
  • Note 3: The maximum load resistance that can be connected is decided depending on the powersupply voltage.

 

Relation between power supply voltage and load resistance

Relation between power supply voltage and load resistance

  • Note 4: When the sensor cable, the transmission cable, or the contact input cable is extended by 30 m or more, the surge test under the EMC Directive for CE marking is not applied.
  • Note 5: An arrester (spark over voltage: 400 V) is implemented for transmission output, contact input, and communication. However, use a most suitable surge absorption element on the connection lines in accordance with the ambient environment, the situation of equipment installed, and the externally connected equipment.

Запросить информацию

У вас есть вопросы или пожелания? Используйте эту форму, чтобы связаться с нашими специалистами.

* Эти поля обязательны для заполнения.

Related products

514-22
514-22

1.41 mS/cm Conductivity Standard Solution

514-23
514-23

12.9 mS/cm Conductivity Standard Solution

9371-10D Conductivity Cell
9371-10D Conductivity Cell

Conductivity Cell for Ultra Pure Water Measurement

CS-600F
CS-600F

Fiber Optic Type Chemical Concentration Monitor

CS-620F
CS-620F

Optical Fiber Type Hot Phosphoric Acid Concentration Monitor

CS-900
CS-900

Non-Contact Chemical Concentration Monitor

H-1 Series
H-1 Series

Field-installation type water quality measuring instruments

HC-200F
HC-200F

Field-installation Type Fluoride Ion Concentration Meter

HC-200NH
HC-200NH

Field-installation type ammonia nitrogen meter

HC-300F
HC-300F

Field-installation Type Fluoride Ion Concentration Meter

HD-200
HD-200

Field-installation type dissolved oxygen meter (DO meter)

HD-200FL
HD-200FL

Field-installation type optical dissolved oxygen meter (DO meter)

HD-300
HD-300

Field-installation type dissolved oxygen meter (DO meter)

HD-480
HD-480

Panel-mount type dissolved oxygen meter (DO meter)

HD-960L
HD-960L

HF (Hydrofluoric Acid)  DO (Dissolved Oxygen) Monitor / Pure Water DO (Dissolved Oxygen) Monitor

HD-960LR
HD-960LR

Dissolved Oxygen Concentration Monitor Series for Semiconductor Manufacturing

HE-200C
HE-200C

Field-installation type electric conductivity meter (conductivity meter)

HE-200H
HE-200H

Field-installation type electric conductivity meter

HE-200R
HE-200R

Field-installation type electric resistivity meter (resistivity meter)

HE-300R
HE-300R

Field-installation type electric resistivity meter (resistivity meter)

H-1 Series
H-1 Series

Field-installation type water quality measuring instruments

HD-200
HD-200

Field-installation type dissolved oxygen meter (DO meter)

HD-300
HD-300

Field-installation type dissolved oxygen meter (DO meter)

HD-480
HD-480

Panel-mount type dissolved oxygen meter (DO meter)

HD-960L
HD-960L

HF (Hydrofluoric Acid)  DO (Dissolved Oxygen) Monitor / Pure Water DO (Dissolved Oxygen) Monitor

HD-960LR
HD-960LR

Dissolved Oxygen Concentration Monitor Series for Semiconductor Manufacturing

HE-200C
HE-200C

Field-installation type electric conductivity meter (conductivity meter)

HE-200H
HE-200H

Field-installation type electric conductivity meter

HE-200R
HE-200R

Field-installation type electric resistivity meter (resistivity meter)

HE-300R
HE-300R

Field-installation type electric resistivity meter (resistivity meter)

HE-480C
HE-480C

Panel-mount type conductivity meter (conductivity meter)

HE-480C-GC
HE-480C-GC

Carbon Sensor Conductivity Meter (Low concentration type)

HE-480H
HE-480H

Panel-mount type conductivity meter (conductivity meter)

HE-480R
HE-480R

Panel-mount type resistivity meter (resistivity meter)

HE-480R(W)
HE-480R(W)

Resistivity Meter for Semiconductor Cleaning Processes

HE-960CA
HE-960CA

Citric Acid Monitor

HE-960CW
HE-960CW

Panel-mount type 2-channel conductivity meter (conductivity meter)

HE-960H-KOH
HE-960H-KOH

KOH Monitor

HE-960H-TM
HE-960H-TM

Wide range TMAH Concentration Monitor

HE-960H-TM-S
HE-960H-TM-S

High Precision TMAH Concentration Monitor

HE-960HC
HE-960HC

Carbon Sensor Conductivity Meter (High concentration type)

HE-960HI
HE-960HI

Panel-mount type conductivity meter

HE-960LC
HE-960LC

Carbon Sensor Conductivity Meter

HE-960LF / FS-09F-1/2
HE-960LF / FS-09F-1/2

Flat Carbon Sensor Conductivity Meter

HE-960R-GC
HE-960R-GC

Carbon Sensor Resistivity Meter

HE-960RW
HE-960RW

Panel-mount type 2-channel electric resistivity meter (resistivity meter)

HE-960RW-GC
HE-960RW-GC

2-Channel Resistivity Meter

HF-700A
HF-700A

Low Concentration Monitor- Sulfuric Acid/Hydrogen Peroxide

HF-960H
HF-960H

HF / HCl Concentration Monitor

HF-960M
HF-960M

Low Concentration Type HF/HCl/NH3 Concentration Monitor

HO-200
HO-200

Field-installation type ORP meter

HO-300
HO-300

Field-installation type ORP meter

HO-480
HO-480

Panel-mount type ORP meter

HR-200
HR-200

Field-installation type polarographic residual chlorine meter

HR-200RT
HR-200RT

Field-installation type residual chlorine meter

HR-480
HR-480

Panel-mount type galvanic residual chlorine meter

Вода & Жидкости Corporate