HD-200FL

Field-installation type optical dissolved oxygen meter (DO meter)

Optical sensors improve ease of maintenance.

Ideal for the management of aeration tanks at facilities such as wastewater treatment plants and industrial wastewater treatment facilities. Optical sensors do not require concerns about electrolyte replacement or membrane breakage. The system also offers further enhanced functionality, such as automatic recognition of membrane-specific coefficients characteristics when the sensor cap is replaced.

Division: Process Water
Manufacturing Company: HORIBA Advanced Techno Co., Ltd.

IC built-in memory sensor cap

Automatic recognition of membrane-specific coefficients eliminates the need to input them when replacing the sensor caps (fluorescent film).

Possible to be combined with a float-type holder

Self-cleaning action uses flow velocity of measured liquid preventing accumulated contamination.  The shape of the sensor prevents dirt and floc from clinging to the sensor part.

Possible to be combined with ultrasonic cleaners

Can be combined with an ultrasonic cleaner, which is effective for use in aeration tanks.  Furthermore, since the sensor is designed to be dropped into the holder, it offers ease of maintenance.

Strengths of the sensor

The sensor offers a longer lifespan compared to other measurement methods. Moreover, with an optical sensor, there are no concerns about membrane damage, and the membrane can be easily replaced by exchanging the entire cap. Three cleaning methods are available (water jet, air jet, and ultrasonic).

Indication converter specifications

ModelHD-200FL
Measuring methodOptical (fluorescent)
Measuring rangeDO: 0 to 20 mg/L      Resolution: 0.01 mg/L
Saturation: 0 to 200%    Resolution: 0.1%
Temperature: 0 to 50°C   Resolution: 0.1°C
RepeatabilityWithin ± 1% of full scale
LinearityWithin ±2% of full scale
Transmission
output
2 points 4 mA to 20 mA DC output isolated type Maximum load resistance 900 Ω
 Range 1: DO concentration: Freely selectable within the measurement range
 Range 2: Temperature: Freely selectable within the range from -10.0 to 110.0°C
 Alarm: Burnout function (3.8 mA or 21 mA)
 Hold: Selectable from previous value hold, optional value hold
Contact
output
3 points Dry contact output Relay contact, SPDT (1c)
 Signal R1, R2: upper limit alarm, lower limit alarm,
        hold, Cleaning (selectable)
      FAIL : Alarm
 Control operation Control width: 0.02 to 4.00 mg/L (±0.01 to ±2.00 mg/L)
On cleaning
output
1 point Wet contact output (connecting power supply voltage output) Relay contact, SPST (1a)
 Contact function: Solenoid Valve Control
External input1 point Contact shape: Open connector dry ‘a’ contact
 Contact function: Cleaning Unit Control
Communication functionRS-485 2-line, insulated input/output (transmission output is not insulated)
Temperature
compensation range
0 to 50°C
Temperature
compensation device
Thermistor
Calibration methodAtmosphere span calibration, zero liquid (sodium sulfite) calibration, span liquid (atmosphere saturation liquid) calibration
Self-diagnosis functionCalibration error, sensor diagnosis error, converter alarm
Operating temperature range-20 to 55°C (Should not be frozen)
Power supply90 to 264 V AC 50/60 Hz Power consumption: 15 VA (max)
StructureIP65 : 50 A pole or wall mounting
Case: Aluminum alloy Mounting brackets, hood: SUS304
MassMain unit body: Approx. 3.5 kg   Hood, mounting brackets: Approx. 1 kg
Regulatory complianceCE marking, FCC
Compatible sensorDO-2000

*1     When extending the sensor cable, transmission cable, or contact input cable 30 m or more, the CE marking EMC directive surge test does not apply.
*2     An arrestor (inception voltage: 400 V) is mounted on the unit for transmission output, contact input, and communications. However, an optimal surge absorber should be installed on the connecting line depending on the surrounding environment, equipment setup, externally connected devices, etc.

Probe specifications

ModelDO-2000
Measurement principlesOptics (fluorescence)
Sample water0 to 50°C
Wetted materialSUS316、NBR、PVC
Response time90% response: Within 30 s  95% response: Within 60 s
MassApprox. 3.0 kg (incl. 10 m cable)

Sensor cap specifications (replaceable)

Model5700
Wetted materialNBR, PMMA
MassApprox. 5.0 g
Membrane memoryBuilt-in memory in the membrane unit, automatic recognition

Request for Information

Do you have any questions or requests? Use this form to contact our specialists.

* These fields are mandatory.

Related products

CS-600F
CS-600F

Fiber Optic Type Chemical Concentration Monitor

CS-620F
CS-620F

Optical Fiber Type Hot Phosphoric Acid Concentration Monitor

CS-900
CS-900

Non-Contact Chemical Concentration Monitor

EMGA-921
EMGA-921

Hydrogen Analyzer

EMGA-Expert
EMGA-Expert

Oxygen/Nitrogen/Hydrogen Analyzer
(Flagship High-Accuracy Model)

EMGA-Pro
EMGA-Pro

Oxygen/Nitrogen Analyzer (Entry Model)

HC-200F
HC-200F

Field-installation Type Fluoride Ion Concentration Meter

HC-200NH
HC-200NH

Field-installation type ammonia nitrogen meter

HC-300F
HC-300F

Field-installation Type Fluoride Ion Concentration Meter

HD-200
HD-200

Field-installation type dissolved oxygen meter (DO meter)

HD-300
HD-300

Field-installation type dissolved oxygen meter (DO meter)

HD-480
HD-480

Panel-mount type dissolved oxygen meter (DO meter)

HD-960L
HD-960L

HF (Hydrofluoric Acid)  DO (Dissolved Oxygen) Monitor / Pure Water DO (Dissolved Oxygen) Monitor

HD-960LR
HD-960LR

Dissolved Oxygen Concentration Monitor Series for Semiconductor Manufacturing

HE-200C
HE-200C

Field-installation type electric conductivity meter (conductivity meter)

HE-200H
HE-200H

Field-installation type electric conductivity meter

HE-200R
HE-200R

Field-installation type electric resistivity meter (resistivity meter)

HE-300C
HE-300C

Field-installation type electrical conductivity meter (conductivity meter)

HE-300R
HE-300R

Field-installation type electric resistivity meter (resistivity meter)

HE-480C
HE-480C

Panel-mount type conductivity meter (conductivity meter)

HE-480C-GC
HE-480C-GC

Carbon Sensor Conductivity Meter (Low concentration type)

HE-480H
HE-480H

Panel-mount type conductivity meter (conductivity meter)

HE-480R
HE-480R

Panel-mount type resistivity meter (resistivity meter)

HE-480R(W)
HE-480R(W)

Resistivity Meter for Semiconductor Cleaning Processes

HE-960CA
HE-960CA

Citric Acid Monitor

HE-960CW
HE-960CW

Panel-mount type 2-channel conductivity meter (conductivity meter)

Corporate