CCEVA

Carbon Capture Evaluation System

For the development of CO2 solid adsorption materials, separation membrane materials, and CO2 separation and recovery modules.

To achieve carbon neutrality by 2050, extensive research and development are underway on carbon dioxide (CO2) adsorption materials and their evaluation systems. In the field of CO2 adsorption and separation materials R&D, various separation and recovery methods are employed depending on the source and concentration of CO2.
It is essential to evaluate the performance and durability of these adsorption materials accordingly.

Features of the system

  • A single device can generate gas at any desired concentration, control various test conditions, and analyze the gas after adsorption and desorption.
  • Supports evaluation using real exhaust gas (optional).
  • Various test sequences can be performed automatically, enabling continuous 24-hour testing.
  • Equipped with standard safety functions, including abnormality detection and emergency stop switches.

 

HORIBA’s Solution

Carbon Capture Evaluation System is the solution supporting customers who moves from basic research to demonstration phase of CO2 capture.

  • Enables testing with pressure control
  • Allows testing with a flow rate of several liters per minute
  • Supports long-term continuous testing, such as adsorption/desorption cycle and durability tests
  • Provides evaluation test system in a single package
  • Facilitates highly reproducible automated testing

 

CO2 Adsorption / Desorption Evaluation Test Example

Image of Gas Flow

Ex. Measurement Data

 

Carbon Capture Evaluation System CCEVA

 Analyzer

Up to 3 components incl. CO2 (optional)
<Ex. Specification of CO2 Analyzer>

  •  CO2: 0 - 100 / 1000 ppm (low conc.)
  •  CO2: 0 - 10 / 25 / 100 vol% (high conc.)
    *Both ranges are included

Number of flow path

1

Flow rate range

0.2 to 1 L/min

Pressure range

-70 to +700 kPaG

Chiller temperature control range

-20 to +150℃*

Reactor tube dimensions

To be decided by meeting

Mass flow controller

2 to 3 units (N2 or Air, CO2)

Humidification

Optional

Injected gas

Up to 3 components (Optional)

*The chiller’s temperature control range may vary depending on the heat transfer liquid

 

Dimensions (Unit:mm)

*Appearance and dimensions may vary depending on the specifications.

Carbon Capture Evaluation System CCEVA

Carbon Capture Evaluation System CCEVA

0.47 MBPDF
Product Line: Process Gas
Manufacturing Company: HORIBA, Ltd.

Request for Information

Do you have any questions or requests? Use this form to contact our specialists.

* These fields are mandatory.

Non-Dispersive Infrared Spectroscopy (NDIR)