Duetta: 2-in-1 Fluorescence & Absorbance Spectrometer

Full Spectra in Milliseconds for Industry and Academia

Duetta™ goes beyond fluorescence alone, enabling faster, more complete molecular characterization with a single instrument. Duetta is a unique, high‑speed spectrofluorometer that simultaneously measures fluorescence and absorbance—delivering true molecular fingerprints in seconds.

Duetta replaces that legacy approach with CCD‑based full‑spectrum acquisition, capturing fluorescence and absorbance together across the UV‑Vis‑NIR range and automatically correcting for Inner Filter Effects (IFE) in real time.

Duetta solves key challenges for academic and industrial labs.

Optimized for Research & Teaching LabsSolves Throughput Obstacles for Industrial Applications
Measure low-concentration samples with confidenceCollect data in seconds
Generate publishable, high-quality dataComplete molecular characterization
Teach spectroscopy concepts efficiently to multiple studentsWorks with complex workflows to increase throughput
Avoid instrument bottlenecks during lab sessionsMultiple instruments in one compact package

Read more about Applications Powered by Duetta on our Duetta Publications page.

 

   Science in Action Series   Spectroscopy Matters Series

Key Features and Performance Benefits

  • 2-in-1 Simultaneous Fluorescence and Absorbance Spectrometer
  • UV-Vis-NIR Fluorescence Detection Wavelength Range from 250 to 1,100 nm
  • Millisecond CCD Detection of Entire Fluorescence Spectrum
  • Full 3-D Fluorescence EEM Acquisition in Less Than One Second
  • Best in Class Fluorescence Sensitivity Specification of 6,000:1 RMS for Water Raman
  • Automatic Correction for Primary and Secondary Inner Filter Effects (IFE)
  • High Fidelity Molecular Fingerprinting with Unique A-TEEM™ (Absorbance-Transmittance Excitation Emission Matrix) Technology

 

Why Scientists Choose Duetta 

  • Speed & Sensitivity: Capture full spectra in milliseconds, enabling kinetic studies and high-throughput screening. 
  • Broad Spectral Range: Analyze samples from UV to NIR, including challenging nanomaterials and biological tissues. 
  • Advanced Data Analysis: Integrated multivariate tools and A-TEEM™ technology for robust molecular fingerprinting and correction of inner-filter effects. 
  • Versatility: Seamlessly switch between absorbance and fluorescence modes for comprehensive sample characterization.

 


Featured Video

A Superior Spectrometer Concept

The Future of Fluorescence

  • Three-in-one Fluorescence and Absorbance Spectrometer
  • UV-Vis-NIR Fluorescence Detection Wavelength Range from 250 to 1,100 nm
  • Full 3-D Fluorescence EEM Acquisition in Less Than One Second
  • Best in Class Fluorescence Sensitivity Specification of 6,000:1 RMS for Water Raman
  • Automatic Correction for Primary and Secondary Inner Filter Effects (IFE)
  • High Fidelity Molecular Fingerprinting with Unique A-TEEM™ (Absorbance-Transmittance Excitation Emission Matrix) Technology
  • Millisecond CCD Detection of Entire Fluorescence Spectrum

Fluorescence and Absorbance in one Spectrometer!

Duetta can be used as a fluorometer, as a UV-Vis-NIR spectrometer to measure absorbance, or as an instrument that measures true molecular fingerprints, which require the acquisition of fluorescence and absorbance, correcting for IFE in real time.

Fluorescence in the Blink of an Eye!

Duetta’s ultra-fast, state-of-the-art CCD technology allows it to outperform, by orders of magnitude, any competitor using PMTs. It’s the fastest bench-top fluorometer in the world, and the only fluorometer that can acquire a full spectrum in less than 100 milliseconds! This state-of-the-art CCD technology also extends NIR wavelength detection to 1,100 nm, well beyond the limit of a standard PMT fluorometer.

Highest Fluorescence Sensitivity in its Class

Having the highest level of fluorescence sensitivity means that Duetta’s optimized design lets you measure lower concentrations of a sample, and provides better quality data.

EzSpec™ Touch-Screen Software!

Duetta debuts HORIBA’s new generation software interface with touch-screen utility, and a selection of Apps for routine analysis.

Watch how EzSpec software performs the Pass/Fail

EzSpec Software obtains a concentration curve

EzSpec Software executes a Protein A280 concentration

EzSpec Software discovers Fluorescence profiles in about 60s

 

 DuettaDuetta-Bio
Acquisition ModesAbsorbance and Fluorescence Spectrometer
Fluorescence SensitivityWater Raman SNR >6,000:1 RMS, 350 nm excitation, 5 nm slits
Spectral Acquisition Rate510,000 nm/min
EEM Acquisition RateAs fast as 1 second (sample and wavelength dependent)
A-TEEM Acquisition RateAs fast as 30 seconds (sample and wavelength dependent)
Fluorescence DetectorCCD/Spectrograph
Fluorescence Detector Range250 to 1,100 nm
Fluorescence Bandwidth1, 2, 3, 5,10, 20 nm (excitation and emission)
Light Source75 W Xenon arc lamp. Dedicated cartidge for snap-in replacement
Excitation/Absorbance Wavelength Range250 to 1,000 nm
Absorbance DetectorSilicon Photodiode
Absorbance Detector Range250 to 1,000 nm
Absorbance Bandwidth1, 2, 3, 5,10, 20 nm
Absorbance Range0 to 2 A
Absorbance Accuracy+/- 0.02 A
Wavelength Accuracy+/- 1 nm
Computer RequirementsWindows 10 or 11 64-bit OS, laptop or PC with at least 1 USB port (more for additional accessories)
SoftwareEzSpec™
Dimensions (W x D x H)17 x 20.4 x 14.4 inches; 43.18 x 51.816 x 36.576 cm
Weight45 pounds; 20.4 kg
Polarizers (Time of Purchase)Not AvailableYes (280 to 750 nm)
Cosmetics
Cosmetics

Rapid Quality Assessment of Essential Oils using Fluorescence Excitation-Emission Matrix Spectroscopy

The Duetta was used to collect Excitation-Emission Matrices that distinguish different species of essential oils, as well as the same species by region of origin. A 50/50 mixture of lavender and eucalyptus demonstrated the ability of the approach to qualitatively identify an adulterant.

Explore application
Food & Beverage
Food

Using Duetta to Detect Saffron Adulteration

Saffron is a target for adulteration due to its high price. Other compounds can be added, such as minerals, oils or synthetic colorants. The two in one Duetta spectrometer was used to rapidly acquire Excitation Emission spectra for different saffron samples from different suppliers.

Explore application
Protein A280 application
Biotechnology & Biomedical
Proteomics | Life Sciences

The Power of Duetta and EzSpec Software for Biological Applications

Duetta is an analytical instrument capable of recording both the fluorescence and the absorbance of a sample. Absorbance data provides concentration-dependant information on non-fluorescent compounds. Through its user-friendly software, Duetta allows different measurements related to biomolecules like DNA, RNA and proteins including protein concentration, DNA/RNA purity, finding the concentration of an unknown sample based on a standard-based calibration curve, Pass/Fail testing and all standard fluorescence and absorbance related measurements. All these functionalities are possible through dedicated applications in EzSpec™ software for Duetta.

Explore application
Fluorescence Emission spectra of transferrin at increasing concentrations
Biopharma
Proteomics | Life Sciences

Protein Quantification at Low Concentration using Fluorescence and Absorbance

In this application note, we highlight the high sensitivity of the Duetta for measuring transferrin at very low concentrations. The Duetta spectrofluorometer combines both fluorescence and absorbance measurements simultaneously, thus providing key advantages for protein analysis. In parallel, we compare the fluorescence results obtained using the Duetta with absorbance results obtained with a dedicated low-volume, benchtop spectrophotometer.

Explore application
Quantum Dots

How Inner-Filter Effects (IFE) can affect your fluorescence measurements: A case study - Colloidal InP Quantum Dots

During the last two decades, a great deal of attention has been focused on the optoelectronic properties of nanostructured semiconductors or Quantum Dots (QDs).

Explore application
A-TEEM™ for Qtracker® 655 quantum dots
Quantum Dots | Nanoscience | Nanomaterials

Quantum Dot Absorbance, Photoluminescence Spectra and Lifetimes

Quantum dots (QDs) are semiconducting spheres in the size typically in the range of 1 to 10nm. The size of these small spheres give quantum dots the semiconducting properties and resulting photoluminescence that would not necessarily occur for the same material on larger scales.

Explore application
Biotechnology & Biomedical
Proteomics

Protein A280 for Protein Concentration

The new HORIBA Duetta fluorescence and absorbance spectrometer offers many unique benefits for molecular spectroscopy. It is primarily thought of as a spectrofluorometer that combines absorbance and fluorescence spectroscopy to correct the fluorescence fingerprint for concentration-related effects. Duetta can also be used as a precise absorbance spectrometer. This application note explores the use of Duetta for a common absorbance application, the Protein A280 application.

Explore application
Art Conservation
Art Conservation

Non-Invasive Analysis of Historical Chinese Textile Dyes using EEM Fluorescence Spectroscopy

This application note describes a breakthrough non-invasive analytical approach using Excitation-Emission Matrix (EEM) fluorescence spectroscopy for identifying natural dyes in Chinese royal textiles from the Qing dynasty (1616-1912 CE).

Explore application
Duetta Brochure

Duetta Brochure

1.7 MBPDF
Accelerating Pharmaceutical Advancements Brochure

Accelerating Pharmaceutical Advancements Brochure

4.28 MBPDF
A-TEEM eBook

A-TEEM eBook

A-TEEM™ or simultaneous Absorbance Transmittance and a fluorescence Excitation Emission Matrix is a new molecular spectroscopy fingerprinting technique, ideal for comprehensive component analysis in a variety of research and QC/QA applications.

5.25 MBPDF
Fluorescence Product Line Brochure

Fluorescence Product Line Brochure

16.83 MBPDF
Duetta Automatic Correction of Fluorescence Spectra for Primary and Secondary Inner-filter Effects (IFE) technote

Duetta Automatic Correction of Fluorescence Spectra for Primary and Secondary Inner-filter Effects (IFE) technote

1.67 MBPDF
A-TEEM Fluorescence for Identification and Quantification of Fulvic Acid Adulteration in Commercial Humic Products PDF

A-TEEM Fluorescence for Identification and Quantification of Fulvic Acid Adulteration in Commercial Humic Products PDF

1.57 MBPDF
Application Note: Synchronous Scanning with Duetta

Application Note: Synchronous Scanning with Duetta

1.18 MBPDF
Technical Note: Duetta UV-Vis-NIR Fluorescence Detection

Technical Note: Duetta UV-Vis-NIR Fluorescence Detection

0.73 MBPDF
Technical Note: Duetta 3 in 1 Fluorescence and Absorbance Spectrometer

Technical Note: Duetta 3 in 1 Fluorescence and Absorbance Spectrometer

1.22 MBPDF
Software download

EzSpec Version 1.4.3.3 Software Patch for Duetta

Software

146.21 MBEXE
Market: Scientific
Manufacturing Company: HORIBA Instruments Incorporated

Request for Information

Do you have any questions or requests? Use this form to contact our specialists.

* These fields are mandatory.

Fluorescence

What is Fluorescence? The term fluorescence refers to one type of luminescence. Luminescence, broadly defined, is light emission from a molecule. There are several types of luminescence.

Photoluminescence and Electroluminescence

What is Photoluminescence Spectroscopy Photoluminescence spectroscopy, often referred to as PL, is when light energy, or photons, stimulate the emission of a photon from any matter.