MEXA-1300R

Übersicht

Easy and high accuracy measurement of CO, CO2, HC, O2 (optional) and calculation of AFR and Lambda

MEXA-1300R is a motor exhaust gas analyzing system for two and four stroke engine assembly lines and has an integrated sample handling system for removal of oil and moisture.
The measurement of CO, CO2, HC and O2 (optional) in exhaust gases is made simply by inserting the sample probe into the tail pipe. AFR and Lambda are also calculated from the exhaust gas concentrations.

Merkmale

  • Calendar Timer Function
    The start time and end time of the instrument can be set for each day of the week.
    A warmup sequence and a purge are carried out automatically.
  • Self-Diagnosis Function
    Instrument parameters such as sample flow rate and temperature of the electronic cooler are monitored to ensure highly accurate and reliable measurements.
  • Measurement Value Judgment Function
    Using AUTO mode, measurement, judgment and then purge are made continuously.
  • Small Footprint
    11% smaller than previous model. Good design allows it to fit into any workspace.

Hergestellt von HORIBA

Spezifikationen

Compatible standards

CE, FCC (Class A)

Reference standard

OIML R99 Class 0

Analyzing target

Exhaust gases of two-cycle and four-cycle engines

Measurement item and range

CO : 0.00% vol - 10.00% vol
HC : 0ppm vol - 10,000ppm vol (N-hexane)
CO2 : 0.00% vol - 20.00% vol
AFR : 10.0 - 30.0
Lambda : 0.500 - 2.500
O2 : 0.00% vol - 25.00% vol (Optional)

Principle / Calculation method

CO,CO2,HC : NDIR (Non-dispersive infrared gas analysis)
O2 : galvanic cell type sensor
AFR, Lambda :  carbon balance method or Bretschneider method
 (When O2 sensor is embedded)

Operating environment

Temperature : 5 ℃ - 35 ℃
Humidity  : 85% RH or less (No condensation)
Atmospheric pressure : 86 kPa - 106 kPa

Configuration

Main body (Analysis unit, control unit, display integrated in main body)

Communication interface

HOST (RS-232C) : D-sub 9 pin (Male)
HOST (LAN) : RJ-45
Analog output  : D-sub 9 pin (Female) 0 - 1 V 6 ch (Optional)

Power supply

Any of the following voltage and frequency
(To be specified when ordering)
100±10 V AC, 50 / 60 Hz±1 Hz, single phase
110±11 V AC, 50 / 60 Hz±1 Hz, single phase
115±11.5 V AC, 50 / 60 Hz±1 Hz, single phase
120±12 V AC, 60 Hz±1 Hz, single phase
200±20 V AC, 50 / 60 Hz±1 Hz, single phase
220±22 V AC, 50 Hz±1 Hz, single phase
230 (207 - 250) V AC, 50 Hz±1 Hz, single phase
240 (216 - 250) V AC, 50 Hz±1 Hz, single phase

Power consumption

Approx. 250 VA (100 V AC - 240 V AC)

Dimensinons

Approx. 430 (W) x 400(D) x 900(H)mm

Mass

Approx. 60 kg

Diagramme

Outside dimensions (mm)

Zubehör

Options

Operation, status confirmation and measurement result display are available on the panel.