HO-480

Panel-mount type ORP meter

A compact water quality meter that offers a wide range of features and functionality.

Suitable for managing neutralization reaction processes such as aeration tanks and denitrification tanks. We offer a wide range of cleaning devices to accommodate a variety of samples.

Abteilung: Process Water
Produktionsfirma: HORIBA Advanced Techno Co., Ltd.

Comprehensive range of cleaning devices.

The ultrasonic cleaner can be retrofitted to HO-480 sites that are not equipped with a cleaner.   *If other cleaners are to be used, sequence control by the customer is required.

Product nameORP meter
ModelHO-480
Measuring range±2000 mV: resolution of 1 mV
RepeatabilityWithin ±5 mV (method by reference voltage input)
LinearityWithin ±5 mV (method by reference voltage input)
Transmission
output
4 mA to 20 mA DC: input/output isolated type
Maximum load resistance: 900 Ω
Transmission output range: Free setting within the measuring range
Contact outputOutputs: 2 points
Alarm contact output (R1 and R2)
  Contact type: relay contact, SPDT (1c)
  Contact rating: 240 V AC, 3 A and 30 V DC, 3 A (resistance load)
  Contact function: selectable from upper/lower limit operation (ON/OFF control), alarm, and under maintenance.
Transmission
output hold feature

Selectable function

  • Holding at the latest value
  • Holding at the preset value
  • Real data output without holding
    (In the maintenance mode, the latest value is held.)
Self-diagnosis
function
  • Outside of the measuring range
  • Converter error
Ambient
temperature
−5℃ to 45℃
Relative humidity20% to 85% (without dew condensation)
Storage
temperature
−25℃ to 65℃
Power supplyRated voltage 100 V AC to 240 V AC, 50/60 Hz, 10 VA (max.)
StructureIndoor-use panel installation type
  Panel case: ABS, Terminal: PBT
Panel: IP65 dust and water proof structure
Protective structurePanel: IP65 (IEC60529, JIS C0920)
Rear case: IP20
Teminal:IP00
Class II device (IEC61010-1)
Pollution level 2 (IEC61010-1)
Conforming
standards
CE MarkingEMC Directives EN61326-1
Low Voltage Directive EN61010-1
RoHS Directive: EN50581
Class A, Industrial electromagnetic environment
  Immunity (Industrial electromagnetic environment)
  Noise increase ±0.2 pH or less
FCC RuleFCC Part15
External
dimensions
48 (W) mm × 96 (H) mm × 115 (D) mm
Case depth: approx. 105 mm
MassApprox. 400 g

Informationsanfrage

Sie haben Fragen oder Wünsche? Nutzen Sie dieses Formular, um mit unseren Spezialisten in Kontakt zu treten.

* Diese Felder sind Pflichtfelder.