CVS-ONE

CVS-ONE- Amostrador de Volume Constante
CVS-ONE- Emissões Diluídas
CVS-ONE- Amostragem de gases de escape
CVS-ONE- Teste de Emissões

Constant Volume Sampler for Diluted Vehicle and Engine Emissions

Accurate diluted-emissions measurement requires stable dilution flow, representative exhaust sampling and careful control of background contamination—particularly as regulated emission levels continue to decrease.

The CVS-ONE is a Constant Volume Sampler designed to dilute vehicle or engine exhaust with filtered air and support accurate emissions measurement over a defined test cycle. When combined with measurement systems such as MEXA-ONE, it supports the calculation of total mass emissions and fuel consumption for certification testing and engine, vehicle and aftertreatment development.

A wide selection of dilution-flow configurations, flexible bag-sampling options and separate main sampling lines allow the system to be configured for light-duty vehicles, engines, hybrid and plug-in hybrid vehicles, and different fuel types. Compact system architecture helps reduce the test-cell footprint while preserving the measurement performance required for low-emission testing.

As part of HORIBA ONE PLATFORM, CVS-ONE can be operated and monitored alongside compatible HORIBA measurement systems through a common software environment. This helps engineers coordinate equipment, monitor system conditions and manage measurement workflows from a centralized interface.

Accurate Diluted-Exhaust Sampling

CVS-ONE provides controlled dilution and representative sampling of vehicle or engine exhaust for emissions measurement and mass-emissions calculation.

CVS-ONE dilution system showing vehicle exhaust mixed with dilution air for bag sampling and emissions analysis.

  • Critical Flow Venturi flow control
  • Stable dilution-flow measurement throughout the test cycle
  • Configurations for different vehicle, engine and exhaust-flow requirements
  • Separate main sampling lines available for flexible system design
  • Supports integration with MEXA-ONE and compatible emissions analyzers
  • Suitable for low-emission measurement applications
     

Flexible Flow and Sampling Configurations

Different powertrains, test cycles and exhaust-flow ranges require different dilution and sample-storage arrangements. CVS-ONE can be configured to match the laboratory’s testing requirements.

  • Multiple dilution-flow configurations available
  • Maximum standard flow rates from 20 to 40 m³/min, depending on model
  • Optional specifications available for higher-flow engine applications
  • Manual single-venturi and automatic multi-venturi configurations
  • Heat-exchanger configurations available
  • Additional sampling bags can be installed after initial system installation
  • Supports a maximum of 20 bags, depending on configuration
  • Suitable for gasoline, diesel and alternative-fuel testing


Final flow capacity and system arrangement should be confirmed for each application.


Compact Design for Flexible Test-Cell Layout

Alt text: Compact CVS-ONE Exhaust Sampling Unit for installation in an emissions test cell.CVS-ONE reduces the space required for diluted-exhaust sampling equipment, giving laboratories more flexibility when planning new installations or updating existing test cells.

  • Up to 65% less system volume than previous HORIBA systems
  • Up to 70% smaller footprint
  • Compact Exhaust Sampling Unit design
  • Bag Sampling Unit can be integrated into the MEXA-ONE cabinet
  • Shorter connections between sampling and analysis equipment
  • Improved equipment accessibility and test-cell layout flexibility


The reduction figures depend on the system specification, including the Exhaust Sampling Unit and heat-exchanger configuration.


Low-Emission Measurement and Contamination Control

At very low emission levels, residual gas, sampling-line contamination and background conditions can significantly influence results. CVS-ONE includes functions intended to help engineers identify and reduce these effects.

  • Short gas-line arrangement between the bag-sampling unit and analyzers
  • Enhanced sampling-line purge functions
  • Automatic system blank or null testing
  • Historical management of system blank results
  • Water-monitor option to support dilution-factor selection
  • Low-concentration CO2 measurement options designed to minimize water interference
  • System quality-check and performance-history functions
  • Optional automatic propane-check capability


Fuel-Consumption Testing for Hybrid Powertrains

CVS-ONE supports fuel-consumption evaluation for vehicles whose engines may start and stop repeatedly during a test cycle.

  • Supports hybrid and plug-in hybrid vehicle testing
  • Bag sampling can be coordinated with engine operating conditions
  • Supports up to five bag pairs for continuous testing, depending on configuration
  • Measurement results can be evaluated with compatible analyzer and automation systems
  • Quality-check history supports ongoing verification of system performance


Flexible Bag Sampling for Complex Test Cycles

  • Configure bag combinations according to the test procedure
  • Add sampling bags after system installation
  • Support multi-phase and extended test cycles
  • Coordinate bag sampling with vehicle or engine operating states
  • Store diluted-exhaust samples for subsequent concentration analysis


Integrated with HORIBA ONE PLATFORM

HORIBA ONE PLATFORM Logo

CVS-ONE uses the same operating environment as compatible HORIBA ONE Series measurement systems.

  • Operate CVS-ONE and compatible emissions analyzers from one interface
  • View sampling-system and analyzer status from a centralized display
  • Monitor system conditions, alarms and operational messages
  • Support measurement preparation and system quality checks
  • Apply more consistent operating procedures across test cells
  • Expand the measurement system as laboratory requirements evolve
  • Integrate CVS-ONE into broader emissions measurement and test-automation workflows


HORIBA ONE PLATFORM provides a common environment for equipment operation, system monitoring, maintenance information and laboratory expansion. Integration capabilities depend on the selected equipment and system configuration. Learn more about HORIBA ONE PLATFORM.

Measurement screen: HORIBA ONE PLATFORM measurement screen for operating CVS-ONE with MEXA-ONE.

HORIBA ONE PLATFORM measurement screen for operating CVS-ONE with MEXA-ONE.
System View screen: HORIBA ONE PLATFORM System View showing the operating condition of connected emissions measurement equipment.

HORIBA ONE PLATFORM System View showing the operating condition of connected emissions measurement equipment.

Aplicações

CVS-ONE supports diluted-exhaust measurement across a range of certification and development programs.


Regulatory Testing

CVS-ONE can be configured to support vehicle and engine emissions testing conducted according to applicable regional procedures. Required flow range, bag configuration, sampling arrangement, analyzers and automation should be selected according to the applicable regulation and vehicle or engine category.


CVS-ONE is available in multiple configurations to accommodate different dilution-flow requirements, sampling arrangements and test-cell layouts. Select the appropriate model based on the required maximum flow rate, heat-exchanger configuration and mixing-tee arrangement.

Final system specifications depend on the selected configuration and testing requirements. Please contact HORIBA for assistance selecting the appropriate CVS-ONE model.

ModelosCVS-ONE
-SV
CVS-ONE
-SV-HE
CVS-ONE
-MV
CVS-ONE
-MV-HE
Controle de fluxoVenturi de Fluxo Crítico (CFV)
Variação VazãoManual (Sistema Venturi Simples)Automático (Sistema Multi-Venturi)
Vazão máxima ※120 m³ /min20 m³ /min30 m³ /min30 m³ /min40 m³ /min
Permutador de calor-●-●●
Conexão em T integrada para mistura●----
Dimensões
Massa
Unidade de Amostragem de Gases de Escape (ESU)655 (L) × 855 (C) × 1970 (A) mm1310(L) × 855(C)
× 1970(A) mm
Aproximadamente 350 kgAproximadamente 400 kg ※2Aproximadamente 500 kgAproximadamente 800 kg
Unidade de Amostragem de Sacos (BSU)Para ser integrado no gabinete MEXA-ONE
Ambiental
condições
Temperatura5 a 40 graus Celsius
Umidade80% ou menos de umidade relativa
Pressão atmosférica
e altitude
80 a 105 kPa (até 2000 m acima do nível do mar) ※3

※1 Contact HORIBA regarding optional configurations, including higher flow rates for heavy-duty engine applications.
※2 Mass shown for systems without an integrated mixing tee.
※3 Operation at lower atmospheric pressures from 80 to 93 kPa—approximately 700 to 2,000 meters above sea level—must be specified as an optional configuration when ordering.


Optional Equipment

Optional equipment is available to support heated sample storage, system calibration and quality-control procedures.

  • Heated Bag Cabinet (HBC): Maintains heated sample bags for applications requiring controlled sample temperatures.
  • Flow Calibration Unit (SAO): Supports verification and calibration of CVS flow measurement.
  • Propane Check Unit (CFO-202): Supports automated propane-check procedures for evaluating hydrocarbon recovery through the sampling system.


Optional equipment availability and compatibility depend on the selected CVS-ONE configuration

Fale conosco

Você tem alguma dúvida ou solicitação? Utilize este formulário para entrar em contato com nossos especialistas.

*Esses campos são obrigatórios.

Acessórios de produto

CFO-ONE
CFO-ONE

Orifício de fluxo crítico automático

Produtos relacionados

Série CRITERION™ (D500)
Série CRITERION™ (D500)

Módulo de Fluxo de Massa Insensível à Pressão D500

Série CRITERION™ (D700MG)
Série CRITERION™ (D700MG)

Módulo de Fluxo de Massa Insensível à Pressão de Alta Velocidade e Precisão D700MG

Série CRITERION™ (D700T)
Série CRITERION™ (D700T)

Módulo de vazão mássica insensível à pressão de melhor desempenho D700T

Série CRITERION™ (D700uF)
Série CRITERION™ (D700uF)

Módulo de Fluxo de Massa Micro Insensível à Pressão D700uF

Série CRITERION™ (D700WR)
Série CRITERION™ (D700WR)

Módulo de vazão mássica de ampla faixa, insensível à pressão, D700WR

Série CRITERION™ (DZ-100)
Série CRITERION™ (DZ-100)

Módulo de Fluxo de Massa Ultrafino DZ-100

EXFM-ONE
EXFM-ONE

Ultrasonic Exhaust Flow Meter for Real-Time Emissions Measurement

Série FQ
Série FQ

Sistema de Medição de Fluxo de Combustível

FS-3000
FS-3000

Divisor de fluxo térmico

Série HyFQ-2000
Série HyFQ-2000

Medidor de Fluxo de Combustível Hidrogênio

Série LE
Série LE

Sistema de controle de vaporização de fonte líquida de grande fluxo

Série LF-F/LV-F
Série LF-F/LV-F

Medidores/Controladores Digitais de Vazão Mássica de Líquidos

Série LSC
Série LSC

Sistema de cozimento compacto

Série LU
Série LU

Sistema de recarga automática de líquidos

MI-1000/MV-1000
MI-1000/MV-1000

Vaporizadores de Líquidos para Sistema de Injeção Mista

MV-2000
MV-2000

Vaporizador de Líquido do Sistema de Injeção Mista

PTFM-1000V2
PTFM-1000V2

Medidor de fluxo de escape do tubo de Pitot

PTFM-ONE-DT
PTFM-ONE-DT

Medidor de fluxo de escape de tubo Pitot duplo

Série SEC-8000 F/D/E
Série SEC-8000 F/D/E

Controlador de fluxo de massa digital para alta temperatura

Série SEC-E
Série SEC-E

Controlador de Fluxo de Massa

Série SEC-N100
Série SEC-N100

Controlador de fluxo de massa digital

Série SEC-Z500X
Série SEC-Z500X

Controlador de Fluxo de Massa Digital Multifaixa/Multigás

Série SEC-Z700S
Série SEC-Z700S

Novo conceito de módulo de vazão mássica insensível à pressão

Série SEC-Z700X
Série SEC-Z700X

Controlador de fluxo de massa insensível à pressão

Série VC
Série VC

Sistema de Injeção Direta de Líquidos