EMIA-Expert

Carbon/Sulfur Analyzer

High Performance Model: EMIA-Expert 
For expert analysis demanding the greatest accuracy and precision

The EMIA-Expert Carbon/Sulfur Analyzer is based on HORIBA’s widely respected expertise in Non-Dispersive Infrared (NDIR) technology. 
It offers improved the cleaning efficiency, enhanced user-friendly software, durability, operability and maintenance to ensure efficient measurements and its shortened cycle time accelerates your development and manufacturing speed.

 

Advanced functions for EMIA-Expert

EMIA-Expert has advanced functions to realize high performance analysis in addition to standard functions of EMIA-Pro.

High Performance Purifier Unit for Carrier Gas

Enables measurement of ultra-low carbon concentration with high accuracy by eliminating hydrocarbon impurities in the carrier gas.

High Performance Heating Filter Unit

Samples which are moist or that generate water during analysis may cause a small error for the analysis of sulfur. This is due to the evolved water absorbing the SO2 gas. Using the heating filter, the absorption of SO2 by moisture is prevented, and highly accurate sulfur analysis is guaranteed. 

 

 

Segmento: Scientific
Fabricante: HORIBA, Ltd.

Long MTBM (Mean Time Between Maintenance)

The unique newly-developed cleaning mechanism (patent pending) clears the dust in the furnace, allowing the operator to continue to use the EMIA-Expert/Pro without maintenance cleaning for up to 200 measurements*.
* It depends on sample and measurement condition

      

      Before measurement             After 200 measurements

 

High Throughput

EMIA Series can complete one measurement cycle, “measurement-display result-cleaning”, in 70 seconds (i.e. about 50 samples/hour)


Fast & Easy Maintenance

With the latest innovations the cleaning time for the EMIA Series instruments is  typically half of that of our conventional models. The flat design around the crucible stand and simple design around the furnace also simplify user access for cleaning.

 

Flat design around the crucible stand     


Advanced Operation software

A critical focus was to ensure that the EMIA-Expert/Pro Series was “easy-to-use”. In particular, we focused on the layout, operating menus and functions.
We have included a self-diagnostic monitor checking capability to check the status of the connected device, an alarm function and we have expanded 3 navigators to facilitate daily operation.

* Analysis Navigator 

This function uses the recommended best measurement flow and operating condition based on our experience. 

* Troubleshooting Navigator 

Automatic diagnosis system and troubleshooting navigator. 

* Maintenance Navigator 

Periodic preventive maintenance work navigator by videos and photos. 


Option

The customer can extend the system’s functionality at any time, even after installation, depending upon their needs.
* Auto-sampler (20 positions)
* Halogen trap unit

 

ContentsEMIA-Expert
Required sample amount1g ± 0.1g
Typical Meas. time70 seconds/cycle
CarbonMeas. Range (m/m)0.6 ppm - 10.0%
Blank accuracyσn-1≦ 0.3 ppm
SulfurMeas. Range (m/m)0.6 ppm - 1.0%
Blank accuracyσn-1 ≦ 0.3 ppm
Sample meas. AccuracyCarbonσn-1 ≦ 0.3 ppm(less than 20 ppm) 
σn-1 ≦ 1.0 ppm or RSD≦0.5%(more than 20 ppm)
Sulfurσn-1 ≦ 0.3 ppm(less than 20 ppm) 
σn-1 ≦ 1.0 ppm or RSD≦0.75%(more than 20 ppm)
UtilityCarrier gasOxygen
(Purity; 99.5%, Pressure; 0.3-0.33 MPa)
Operation gasNitrogen
(Purity; 99.5%, Pressure; 0.35-0.38 MPa)
Power200/220/240V, 50/60Hz, 5kVA
DimensionsMain unit*500(W) x 725(D) x 710(H) mm
Purifier unit160(W) x 560(D) x 512(H) mm
MassMain unitapproximately 134 kg
Purifier unitapproximately 21 kg
Data processing and operationUSB data communication with PC Windows 8.1
Touch panel or Key board and mouse operation
Model nameEMIA-20E: Carbon/Sulfur
EMIA-21E: Carbon
EMIA-22E: Sulfur

Note) "ppm" is equal to mg/kg.

*Except piping parts, projection parts (D:79mm) and flow meter on the back side.


Schematics


Accessories

Crucible Pre-heating Unit

The crucible pre-heating unit; FK-100 with automatic transportation function to heat a ceramic cruible at 1100 degree in 10min. before analysis.

Autosampler

Automation crucible loading and disposing unit. Up to 20 pcs of crucible are available to be set.

Consumables

Ceramic crucible

Low carbon blank and high dimension tolerance for high precision analysis.

Accelerators

High-purity materials which support stable analysis: Tungsten(W), Tin(Sn), Copper(Cu), Iron(Fe)

Quantitative analysis of carbon contained in bone substitute material
Quantitative analysis of carbon contained in bone substitute material
Can we accurately and quickly measure the amount of carbon contained in the material?
Measurement of Carbon and Sulfur in Cement
Measurement of Carbon and Sulfur in Cement
This application note describes the method and conditions to use with the EMIA 820V C/S analyzer to measure cement.
Battery Evaluation in Electrical Equipment
Battery Evaluation in Electrical Equipment
Measurement of Sulfur in Rubber
Measurement of Sulfur in Rubber
Sulfer is added in the natural rubber to produce plastic materials. However, it is important to measure the sulfer contained in the rubber to define the chemical and mechanical properties of the final product.
Measurement of Carbon in Ferrosilicon
Measurement of Carbon in Ferrosilicon
Ferrosilicon is added as a deoxidant and as an alloying element to steel, that require a special low carbon content. The Low Carbon in Ferrosilicon decreases the electrical conductivity and magnetostriction of electrical steels.
Quality Assurance for the Analysis of Steel by Gas Component Analysis
Quality Assurance for the Analysis of Steel by Gas Component Analysis
Sample Preparation and Sampling Methods for the Gas Analysis of Steel
Sample Preparation and Sampling Methods for the Gas Analysis of Steel
Measurement of Carbon and Sulfur in Copper
Measurement of Carbon and Sulfur in Copper
Copper in reddish metal, it is malleable, ductile and an extremely good conductor of both heat and electricity. Copper metal is widely used for electrical wiring, water piping, and corrosion resistant parts, either pure or in alloy such as brass and bronze. Carbon and Sulfur are considered as impurities, so it is important to measure and check the Copper purity.
Measurement of Carbon and Sulfur in Titanium Oxide
Measurement of Carbon and Sulfur in Titanium Oxide
Titanium oxide are used primarily in the production of paints and plastics and are also used in paper, priniting inks, cosmetics, textiles and food stuffs.
Carbon Analysis: Organic and Inorganic Carbon in Soils
Carbon Analysis: Organic and Inorganic Carbon in Soils
The aim of this application note is to explain the determination of organic and inorganic carbon in soils and how to prepare samples to eliminate inorganic carbon (carbonates) in these soils.

Pedido de Informação

Você tem alguma dúvida ou solicitação? Utilize este formulário para entrar em contato com nossos especialistas. * Esses campos são obrigatórios.

Related products

Auto SE
Auto SE

Spectroscopic Ellipsometer for Simple Thin Film Measurement

EMGA-920
EMGA-920

Oxygen/Nitrogen Analyzer

EMGA-921
EMGA-921

Hydrogen Analyzer

EMGA-930
EMGA-930

Oxygen/Nitrogen/Hydrogen Analyzer

EMGA-Expert
EMGA-Expert

Oxygen/Nitrogen/Hydrogen Analyzer
(Flagship High-Accuracy Model)

EMGA-Pro
EMGA-Pro

Oxygen/Nitrogen Analyzer (Entry Model)

EMIA-Pro
EMIA-Pro

Carbon/Sulfur Analyzer

EMIA-Step
EMIA-Step

Carbon/Sulfur Analyzer

GD-Profiler 2™
GD-Profiler 2™

Discover a Whole New World of Information with Glow Discharge Optical Emission Spectrometer

LabRAM Odyssey
LabRAM Odyssey

Confocal Raman Imaging & High Resolution Spectrometer

LabRAM Soleil
LabRAM Soleil

Multimodal Confocal Raman Microscope

SLFA-60
SLFA-60

X-ray Fluorescence Sulfur-in-Oil Analyzer

SLFA-6000
SLFA-6000

X-ray Fluorescence Sulfur-in-Oil Analyzer

Smart SE
Smart SE

Powerful and Cost Effective Spectroscopic Ellipsometer

UVISEL Plus
UVISEL Plus

Spectroscopic Ellipsometer from FUV to NIR: 190 to 2100 nm

XploRA™ PLUS
XploRA™ PLUS

Raman Spectrometer - Confocal Raman Microscope

XPLORER-NS*
XPLORER-NS*

Total Nitrogen and Sulfur Analyzer

XPLORER-TX/TS*
XPLORER-TX/TS*

Total Halogen and Sulfur Analyzer

EMIA-Pro
EMIA-Pro

Carbon/Sulfur Analyzer

EMIA-Step
EMIA-Step

Carbon/Sulfur Analyzer

SLFA-20
SLFA-20

X-ray Fluorescence Sulfur-in-Oil Analyzer

51 series
51 series

Explosion-proof Gas Analyzer

AP-370 series
AP-370 series

Air Pollution Monitor

APCA-370
APCA-370

Ambient Carbon Dioxide Monitor

APMA-370
APMA-370

Ambient Carbon Monoxide Monitor

EMGA-920
EMGA-920

Oxygen/Nitrogen Analyzer

EMGA-921
EMGA-921

Hydrogen Analyzer

EMGA-930
EMGA-930

Oxygen/Nitrogen/Hydrogen Analyzer

EMGA-Expert
EMGA-Expert

Oxygen/Nitrogen/Hydrogen Analyzer
(Flagship High-Accuracy Model)

EMGA-Pro
EMGA-Pro

Oxygen/Nitrogen Analyzer (Entry Model)

EMIA-Pro
EMIA-Pro

Carbon/Sulfur Analyzer

EMIA-Step
EMIA-Step

Carbon/Sulfur Analyzer

ENDA-5000 series
ENDA-5000 series

Stack Gas Analysis System

GA-370
GA-370

Trace Gas Monitor

GI-700 series
GI-700 series

Stack Gas Analyzer

IR-300
IR-300

Vapor Concentration Monitor

IR-400
IR-400

High-grade type Gas Monitor for Chamber Cleaning End Point Monitoring

LO-300
LO-300

Laser scanning Oil Film Detector

MEXA-1300R
MEXA-1300R

Motor Exhaust Gas Analyzer

MEXA-584L
MEXA-584L

Automotive Emission Analyzer

MEXA-ONE
MEXA-ONE

Motor Exhaust Gas Analyzer

OBS-ONE GS Unit
OBS-ONE GS Unit

On-board Emissions Measurement System

OBS-ONE IRLAM Unit
OBS-ONE IRLAM Unit

On-board NH3/N2O Measurement System for real-world driving

OCMA-500
OCMA-500

Oil Content Analyzer

OCMA-550
OCMA-550

Oil Content Analyzer

PG-300 series
PG-300 series

Portable Gas Analyzer

TX-100
TX-100

Tunable Laser Gas Analyzer

VA-5000 / VA-5000WM Series
VA-5000 / VA-5000WM Series

Multi-Component Gas Analyzer