HORIBA
Websites
Corporate Website
  • Corporate
Market Websites
  • Mobility
  • Energy and Environment Solutions
  • Life Science
  • Healthcare
  • Materials
  • Semiconductor
Countries/Regions
Americas
  • Brazil / Brasil
  • United States / United States
Asia
  • China / 中国
  • India / India
  • Japan / 日本
  • Korea / 한국
  • Singapore / Singapore
  • Taiwan / 台灣
  • Thailand / ประเทศไทย
  • Vietnam / Việt Nam
Europe
  • Austria / Österreich
  • Czech Republic / Česko
  • France / France
  • Germany / Deutschland
  • Poland / Polska
  • Russia / Россия
  • Spain / España
  • Türkiye / Türkiye
  • United Kingdom / United Kingdom
Global
  • International
Search
HORIBA

Fale conosco

Localização

  • Zeta Potential
  • Isoelectric Point Measurement
  • Related Products
  1. Home
  2. Tecnologia
  3. Dispersão de luz
  4. Zeta Potential

Back to Particle Characterization Products Overview
Back to Particle Webinar List
Back to Particle Applications

Zeta Potential: Layout, Calculating, Analysis

Table of Contents

  • What is Zeta Potential
  • Zeta Potential Layout for SZ-100
  • Calculating Zeta Potential
  • Zeta Potential Analysis
  • Technical Notes
  • Related Products

Zeta Potential

Zeta potential is the charge on a particle at the shear plane

Zeta potential is the charge on a particle at the shear plane. This value of surface charge is useful for understanding and predicting interactions between particles in suspension. Manipulating zeta potential is a method of enhancing suspension stability for formulation work, or speeding particle flocculation for water treatment for example. Measuring zeta potential by electrophoretic light scattering allows one to assess the effects of various strategies for manipulating zeta potential. Electrophoretic light scattering exploits the fact that a charged particle responds to an applied electric field.

Zeta Potential Layout for SZ-100

The particle motion due to the applied electric field is measured by light scattering. The particles are illuminated with laser light and therefore the particles scatter light. The frequency of the scattered light is a function of particle velocity due to the Doppler shift. This explains another name for this technique: laser Doppler electrophoresis. A second beam of light (the reference beam) is mixed with the scattered beam in order to sensitively extract the frequency shift in the scattered light. See the figure below showing the scattered beam mixing with the reference beam at the zeta potential detector in the lower right. The measured magnitude of the frequency shift is then used to determine the particle velocity.

Optical layout for zeta potential measurement in the SZ-100

Calculating Zeta Potential

From the known applied electric field and measured particle velocity, the particle mobility is readily determined. Zeta potential is then calculated from mobility by using a model, the most common of which is the Smoluchowski model. The only parameters required for determining zeta potential are liquid dielectric constant, refractive index, and viscosity. This makes the technique rapid and reliable.

The known electric field and measured particle velocity allow for the calculation of particle mobility, and with choice of model, the zeta potential.
Many environmental factors affect zeta potential including pH. A manual or automatic pH titration can identify both the isoelectric point and ranges of maximum zeta potential, and by extension, predicted stability.

In practice, measurements are made by adding a small amount of suspension or emulsion to the measurement cell and inserting the cell into the instrument. The instrument software then automatically determines the appropriate electric field strength, adjusts the reference beam intensity to ensure the optimal signal to noise ratio, collects and analyzes the data, and presents the results to the user. Often, the effect of H+ or other ions on zeta potential is important. In the former case, a pH titration can be performed, and in the latter, the ion concentration is varied (usually on a logarithmic scale) and a series of zeta potential measurements are performed. Significant labor savings can be realized by using an automated titrator to adjust sample pH.

Zeta Potential Analysis

The zeta potential of a sample is most often used as an indicator of dispersion stability. Large zeta potentials predict a more stable dispersion. Fast and accurate measurement of the zeta potential with the nanoPartica SZ-100V2 can enhance understanding of aggregation and flocculation in samples and speed up the process of developing stable formulations, be they dispersions, emulsions or suspensions.

Measurement of the zeta potential, or electrostatic attraction / repulsion, is important to many industries from pharmaceuticals to mineral processing and from water treatment to additives for electronics. The SZ-100V2 enables fast, reliable and accurate measurement of the zeta potential.


For more information about acquiring an instrument, click here.

Back to top

Technical Notes

Z-Average Size Determined by DLS

Z-Average Size Determined by DLS

Dynamic light scattering (DLS) results are often expressed in terms of the Z-average. The Z-average arises when DLS data is analyzed by the use of the technique of cumulants.

0.44 MBPDF
Download
Upper Size Limit of Zeta Potential Measurement

Upper Size Limit of Zeta Potential Measurement

Zeta potential is a measure of the charge on suspended particles. This property is typically more important for suspensions of small particles where there is high surface area and significant particle – particle interactions.

0.57 MBPDF
Download
Lifetime of Zeta Potential Cells

Lifetime of Zeta Potential Cells

There are several zeta potential cell options for the SZ-100V2 including disposable plastic cells intended to last for several measurements before being replaced. This study investigates how many measurements could be made before the cell required replacement.

0.45 MBPDF
Download

Browse Products

nanoPartica SZ-100V2 Series

nanoPartica SZ-100V2 Series

Nanoparticle Analyzer

Mostrar mais
LY-721 pH Controller

LY-721 pH Controller

Mostrar mais

Pedido de Informação

Você tem alguma dúvida ou solicitação? Utilize este formulário para entrar em contato com nossos especialistas.

* Esses campos são obrigatórios.

Products

  • All Products (A-Z)
  • Mobility
  • Energy and Environment
  • Life Science
  • Healthcare
  • Materials
  • Semiconductor

Applications

  • Drinking Water Utilities
  • Automotive Manufacturing
  • Semiconductor Manufacturing Process
  • Research and Testing Laboratories

Technology

  • Glow Discharge Spectroscopy
  • Pressure-based Flowmetry
  • Quadrupole Mass Spectrometry
  • Raman Spectroscopy

Service

  • On-Site Support
  • Spare Parts and Consumables

Company

  • News
  • Events
  • Career
  • History
  • Corporate Culture

Contact

  • Career Contact
  • Contact Form
  • Worldwide Locations
  • Investor Relations Contact

Terms and Conditions Política de Privacidade Cookies HORIBA Group Social Media

© Copyright 2026 - All Rights Reserved