HU-200SS

Field-installation type MLSS meter

Ideal for measuring samples with high turbidity

An MLSS meter that is ideal for measuring samples with high turbidity. The sensor is designed for stable measurements and ease of maintenance. Furthermore, when combined with an ultrasonic cleaner, issues are minimized facilitating ease of maintenance.

Division: Process Water
Manufacturing Company: HORIBA Advanced Techno Co., Ltd.

Stable measurement

This sensor features a long-life LED light source.  Automatically compensating for fluctuations in light intensity through a built-in reference light monitor.

Designed for ease of maintenance

Using a transmitted light type sensor that does not require span calibration.  Additionally, the sensor head is made of PFA resin in order to prevent contamination.

Combined with an ultrasonic cleaner

The ultrasonic cleaner has no moving parts (wipers), making it less prone to trouble, eliminating the need for periodic replacements.  Furthermore, it features a burst oscillation and sweep function, enhancing cleaning power.

Converter

Product nameIndustrial-use MLSS meter
Converter typeHU-200SS industrial-use MLSS converter
Detector typeSS-90 MLSS detector for industrial use
Measurable rangeActivated sludge (MLSS)0 to 20000 mg/L (MLSS)
Kaolin0 to 10000 mg/L (white inorganic powder)
Clay (inorganic mud)0 to 20000 mg/L (gray inorganic mud)
Transmission
output setting
range
Activated sludge (MLSS)Arbitrary setting within the range from 0 to 1000 mg/L to 0 to 20000 mg/L
KaolinArbitrary setting within the range from 0 to 1000 mg/L to 0 to 10000 mg/L
Clay (inorganic mud)Arbitrary setting within the range from 0 to 1000 mg/L to 0 to 20000 mg/L
Display resolution1 mg/L (0 to 10000mg/L)
10 mg/L (10000 to 22000mg/L)
PerformanceRepeatabilityWithin a reading value ±3% or ±10 mg/L, whichever is larger. (sensor connecting sludge measured value)
Transmission
output
Number of output points1
Output typeDC 4 mA to 20 mA, input/output insulation type
Load resistance900 Ω maximum
LinearityWithin ±0.08mA (for output only)
RepeatabilityWithin ±0.02mA (for output only)
Error outputWith the burnout capability (3.8 mA or 21 mA)
Hold capabilityEither the last value hold or the arbitrary value hold is to be selected.
Contact outputNumber of output points3
Output typeNo-voltage contact output
Contact typeRelay contact, SPDT (1c)
Contact capacity250 V AC, 3 A, 30 V DC, 3 A (resistance load)
Contact
capability
R1, R2Selectable from upper limit alarm, lower limit alarm, transmission output Hold, and cleaning output.
(opened at alarm operation, closed usually, closed at power-off)
FAILError warning (normally closed; open when an error occurs; open when the power is turned OFF)
Description of alarm
  • Setmting range: MLSS concentration within the measurable range
  • Delay time: 0 to 600 s
Cleaning outputNumber of output points1
Output typeActive voltage contact output (connected supply voltage output)
Contact typeRelay contact, SPST (1a)
Contact capacity250 V AC 0.5 A
Contact capabilitySolenoid valve drive for cleaning
SettingCleaning
frequency
0.1 h to 168.0 h
Cleaning time2 s to 600 s
Hold time2 s to 600 s
Timer accuracyWithin 2 min per month
Description of cleaning
operation
  • Operation of the internal timer
  • Operation of the internal timer and external contact input
  • The internal timer is enabled only at the time of external contact input.
  • One of the cleaning trigger operations is selected (the internal cleaning sequence starts when external contact input is ON for at least 2 s).
Contact inputNumber of input points1
Contact typeNo-voltage a contact for open collector
ConditionON resistance: 100 Ω maximum
Open-circuit voltage: 24 V DC
Short-circuit current: 12 mA DC maximum
Contact capabilityCan be selected from cleaning directives and transmission hold.
Communication
capability
TypeRS-485
Signal typeTwo-wire input/output insulation type (not insulated from transmission output)
CalibrationCalibration method
  • Zero calibration: With clean water
  • Span calibration: Concentration conversion method using coefficient input
  • Working curve selection: (selection of activated sludge and inorganic mud)
There is a feature that allows you to match an instrument indicated value to a hand analyzed value of sludge (by the Mass method).
Self-checkSensor check errorSensor error
Converter errorCPU abnormality, ADC abnormality, memory abnormality
Operating
temperature range
−20℃ to 55℃ (without freezing)
Operating humidity
range
Relative humidity: 5% to 90% (without due condensation)
Storage
temperature
−25℃ to 65℃
Power sourceRated power supply
voltage
100 V to 240 V AC ±10% 50/60Hz
Power consumption20 V A (max)
OthersA power switch for maintenance is incorporated.
Compatible
standards
CE markingEMC   : EN61326-1
     Class A, Industrial electromagnetic environment
Safety : EN61010-1
RoHS  : EN50581
     9. Industrial monitoring and control instruments
FCC rulesPart15 Class A
StructureInstallationOutdoor installation type
Installation method50 A pole-mounted or wall-mounted
Protection classIP65
Material of caseAluminum alloy (coated with epoxy modified melamine resin)
Material of mounting
brackets
SUS304
Material of hoodSUS304 (epoxy glue degeneration melamine resin painting)
Material of display windowPolycarbonate
Display elementReflective monochrome LCD
External
dimensions
180 (W) mm × 155 (H) mm × 115 (D) mm (excluding brackets)
MassMainframe: approx. 3.5 kg, hood, bracket: approx. 1 kg

*1:  The surge test specified in the EMC Directive for CE Marking shall not apply to the case when a sensor cable, transmission cable, or contact input cable is extended for 30 m or longer.

*2:  An arrester (electric discharge voltage: 400 V) is provided for transmission output, contact input, and communications. However, incorporate and use an optimal surge absorption element on the connected line according to the ambient environment, equipment installation situations, and externally connected equipment, etc.

Detector

Product nameMLSS detector for industrial use
ModelSS-90
Measuring principleLight transmission method
Light sourceInfrared LED, 880 nm, approx. 10 Hz, AC blinking
Detector(transmitted light/reference light)
Cell lengthApprox. 7 mm
Data transferRS-485 (communication with the converter)
Self-checkWater immersion detection
Operating temperature range5℃ to 50℃ (without freezing)
Storage temperature−25℃ to 65℃
Measured liquid pressure0 MPa to 0.2 MPa
Material of wetted partPPO SUS316 PFA FKM EPDM PVC
Cable length10 m (standard), maximum extension: 50 m (overall length: 60 m)
Power source12 V DC supplied from the HU-200SS converter
External dimensions48 mm in diameter x 250 mm in length (excluding the cable)
MassApprox. 0.8 Kg (excluding the cable)

Solicitud de Información

Tiene alguna pregunta o solicitud? Utilice este formulario para ponerse en contacto con nuestros especialistas.

* Estos campos son obligatorios.

Related products

H-1 Series
H-1 Series

Field-installation type water quality measuring instruments

HU-200TB-H
HU-200TB-H

Field-installation type turbidity meter

HU-200TB-IM
HU-200TB-IM

Field-installation type turbidity/SS meter

HU-200TB-W
HU-200TB-W

Field-installation type turbidity meter

OPSA-150
OPSA-150

Organic pollutant monitor

TW-100
TW-100

Water distribution monitor

TW-150
TW-150

Water distribution monitor

U-50
U-50

Multi-parameter water quality checker

CS-100 Series
CS-100 Series

Stand-alone Type Chemical Concentration Monitor

CS-100F1 Series
CS-100F1 Series

Fiber Optic Type Chemical Solution Concentration Monitor

CS-600F
CS-600F

Fiber Optic Type Chemical Concentration Monitor

CS-620F
CS-620F

Optical Fiber Type Hot Phosphoric Acid Concentration Monitor

CS-700
CS-700

High Precision, High Stability Chemical Concentration Monitor

CS-900
CS-900

Non-Contact Chemical Concentration Monitor

EG-100
EG-100

Washwater Monitoring System

H-1 Series
H-1 Series

Field-installation type water quality measuring instruments

HF-960M
HF-960M

Low Concentration Type HF/HCl/NH3 Concentration Monitor

HU-200TB-H
HU-200TB-H

Field-installation type turbidity meter

HU-200TB-IM
HU-200TB-IM

Field-installation type turbidity/SS meter

HU-200TB-W
HU-200TB-W

Field-installation type turbidity meter

HZ-960
HZ-960

Dissolved Ozone Monitor

HZ-960HPO-M
HZ-960HPO-M

H2O2 Monitor

OPSA-150
OPSA-150

Organic pollutant monitor

TPNA-500
TPNA-500

Automatic total nitrogen/phosphorus monitoring system

U-50
U-50

Multi-parameter water quality checker

Corporate