| Product name | Residual Chlorine Monitor |
|---|
| Model | HR-200RT |
|---|
| Sensor type | RA-30 |
|---|
Measurement range | Concentration | 0 mg/L to 3 mg/L (Display range: 0 mg/L to 5 mg/L) |
|---|
| Temperature | 0℃ to 50℃ (Display range: -10℃ to 110℃) |
Display resolution | Concentration | 0.01 mg/L |
|---|
| Temperature | 0.1℃ |
| Performance | Concentration | Repeatability | Within ±0.05 mg/L (Equivalent input) |
|---|
| Linearity | Within ±0.05 mg/L (Equivalent input) |
| Temperature | Repeatability | ±0.5℃ (Equivalent input) |
| Linearity | ±0.5℃ (Equivalent input) |
Transmission output | Number of current outputs | 2 (Negative terminals of each transmission output channel are connected inside and thus have the same electrical potential) |
|---|
| Output type | 4 mA to 20 mA DC, input/output isolated type |
| Load resistance | 900 Ω (Max.) |
| Linearity | Within ±0.08 mA (limited to the current linearity) |
| Repeatability | Within ±0.02 mA (limited to the current repeatability) |
| Output range | Output 1 | Residual chlorine concentration: An arbitrary value can be set within the range from 0 mg/L to 5 mg/L |
| Output 2 | Temperature: An arbitrary temperature can be set within the range from -10℃ and 110℃ |
| Error output | Provided with burnout function (3.8 mA or 21 mA) |
| Hold function | Selectable from between the latest value hold and the preset value hold |
| Contact output | Number of current outputs | 4 |
|---|
| Output type | No-voltage output contact |
| Contact type | Relay contact, R1 to R3: SPST (1a), FAIL: SPDT (1c) |
| Output capacity | R1, R2, FAIL: 250 V AC 3 A/30 V DC 3 A (resistance load) R3: 30 V DC 1 A (resistance load) |
Contact function | R1, R2, R3 | Selectable from among the upper limit alarm, lower limit alarm, ON/ OFF control, during transmission output hold, and during calibration (closed at alarm operation, open under normal conditions and in a power-OFF state) |
| FAIL | Error alarm (closed under normal conditions, open in an error or power-OFF state) |
| Description of alarm operation | - Setting range: 0.00 mg/L to 3.00 mg/L
- Delay time: 0 s to 600 s
|
| Description of control operation | - Setting range: 0.00 mg/L to 3.00 mg/L
- Control width: 0.02 mg/L to 1.00 mg/L (±0.01 mg/L to 0.50 mg/L)
|
| Contact input | Number of input points | 2 |
|---|
| Contact type | Open collector no-voltage “a” contact |
| Condition | ON resistance: 100Ω (max.) Open-circuit voltage: 24 V DC Short-circuit current: 12 mA DC (max.) |
| Contact function | Selectable from among the external input for transmission output hold, flow switch input for interlock (open when the flow rate drops), and calibration command |
Communicati on function | type | RS-485 |
|---|
| Number of circuits | 1 |
| Signal form | Two wire type, the power source of the communication is isolated from the power of measurement circuit (the power source of transmission and communication are not isolated). |
| pH correction | Type | Connected with expansion connector |
|---|
| pH correction range | 5.8 pH to 8.6 pH |
Temperature compensation | Applicable temperature element | Pt1000: 1 kΩ (0℃) (embedded in the detector unit) |
|---|
| Compensation range | 0℃ to 50℃ |
| Calibration function | One point calibration compared with reference temperature range |
| Calibration | Calibration method | Zero calibration (with zero water) Span calibration (comparative calibration with the value measured with the DPD method including electrical zero calibration) |
|---|
| Additional function | Calibration log (number of days elapsed since the zero or last calibration), calibration error automatic judgment (zero) |
Calibration control output (ZERO CAL) | Number of contact output | 1 |
|---|
| Output type | Voltage contact output (connected power source voltage output) |
| Contact capacity | 250 V AC 0.5 A |
| Calibration cycle setting | 1 hour to 999 hour |
| CALR1 | Contact type | Relay contact, SPST (1a) |
| Contact function | Zero water switching driven by solenoid valve |
| Self-check | Calibration error | Zero calibration error, outside the temperature calibration range |
|---|
| Temperature sensor diagnosis | Temperature sensor short-circuit, temperature sensor disconnection |
| Converter error | CPU abnormality, ADC abnormality, memory abnormality |
| Operating temperature range | -20℃ to 55℃ (without freezing) |
|---|
| Operating humidity range | Relative humidity: 5% to 90% (no condensation) |
|---|
| Storage temperature | -25℃ to 65℃ |
|---|
| Power supply | Rated power supply voltage | 100 V to 240 V AC ±10% 50/60 Hz |
|---|
| Power consumption | 35 VA (max.) |
| Others | With built-in power switch for maintenance |
| Structure | Installation | Outdoor installation type |
|---|
| Installation method | Pole-mounted or wall-mounted |
| Protection class | IP65 |
| Material of case | Aluminum alloy (coated with epoxy-modified melamine resin) |
| Material of mounting brackets | SUS304 |
| Material of sun shade hood | SUS304 (coated with epoxy-modified melamine resin) |
| Material of display window | Polycarbonate |
| Display element | Reflective monochrome LCD |
| External dimensions | 180 (W) mm × 155 (H) mm × 115 (D) mm (excluding brackets) |
|---|
| Mass | Main frame: approx. 3.5 kg, Hood, bracket: approx. 1 kg |
|---|