HT-110

On-line TOC analyzer

High-precision continuous measurement of TOC in water used for pharmaceutical manufacturing and similar applications.

HT-110 is a TOC analyzer designed for water used in pharmaceutical manufacturing, which adopts the continuous UV oxidation and conductivity method as the measurement principle. In compliance with the USP (U.S. Pharmacopeia) reference standard, it is characterized by its ability to continuously measure low-concentration ranges, such as water for injection, with high accuracy.

TOC

Division: Process Water
Manufacturing Company: HORIBA Advanced Techno Co., Ltd.

Adoption of UV Oxidation Conductivity Method

The UV oxidation conductivity method, which eliminates the need for reagents and carrier gasses (purge gas) has been adopted. This method allows for high repeatability of ±2% F.S. for low-concentration ranges such as water for injection (WFI) at full scale while simultaneously providing a potential reduction in operating expenses.

Suppression of Erroneous Indications Caused by Air Bubble Inclusion

The equipment has a deaeration mechanism, which suppresses erroneous indications caused by the inclusion of air bubbles.

External control functions

By equipping contact input terminals, it is now possible to perform ON/OFF controls externally.  Useful for situations such as false alarms during SIP cleaning or nighttime shutdown of purified water equipment.

Maintenance cycle of one year

By significantly extending the lifespan of the UV lamp, maintenance is now reduced to a single annual calibration, allowing a maintenance-free period of one year.

Compatible with USP<643>, EP<2.2.44>, JP<G8.4.5.2>

Suitable for TOTAL ORGANIC CARBON measurement according to USP <643>, EP <2.2.44>, and for the suitability testing of "HIGHLY PURIFIED WATER", "WATER FOR INJECTION", and "WATER, PURIFIED" as per EP requirements. It is also ideal for the physicochemical monitoring specified in JP <G8.4.5.2> for PW (Purified Water) and WFI (Water for Injection).

Versatile installation options

The installation methods include pole-mounts, wall-mounts, and tabletops, allowing for flexible installation options tailored to the specific site requirements for versatile installations without limitations.

Product nameTotal organic carbon analyzer (TOC analyzer)
ModelHT-110
Measurement methodContinuous UV oxidation conductivity method
Measurement limit0 ppb to 1000 ppb
Measurement range0 ppb to 100/500/1000 ppb
RepeatabilityWithin ±2% of full scale
Display resolution0.1 ppb (0 ppb to 100 ppb/0 ppb to 500 ppb range)
1 ppb (0 ppb to 1000 ppb range)
Transmission outputNumber of output point: one
4 mA to 20 mA DC/0 V to 1 V DC (optional) insulated input/output
Maximum load resistance: 600 Ω (minimum load resistance 100 kΩ (when optionally selected))
Transmission output range: optional setting possible within measurement range
Output target: TOC concentration
Contact outputNumber of outputs: 2
Alarm contact output (RLY1)
Contact method: relay contact, SPDT (1c)
Contact capacity: 125 V 3 A AC/24 V 3 A DC (load resistance)
Contact function: upper/lower limit function (ON/OFF control)
Output target:
at TOC, temperature, conductivity:
C-NO contact is “closed” during operation, “open” during normal conditions
(including a POWER OFF state) *C-NO contact is reversed at hold, or error:
C-NO contact is “open” during operation (including a POWER OFF state),
“closed” during normal conditions *C-NO contact is reversed
Alarm contact output (RLY2)
Contact method: relay contact, SPST (1a)
Contact capacity: 125 V 3 A AC/24 V 3 A DC (load resistance)
Contact function: upper/lower limit function (ON/OFF control)
Output target: TOC concentration
Contact inputNumber of input point: 1
Non-voltage normal open (1a) signal input (open collector input possible)
Insulation-type input
Max. ON resistance: 50 Ω
Open-circuit voltage: 5 V DC
Max. short circuit current: 10 mA
An error will not be generated even if there is notification of no sample detection
immediately after receipt of the pure water device stop signal receiving
The hold operation during the contact input receiving.
Sample water conditionConductivity: less than 10 μS/cm (less than 2 μS/cm in 0 ppb to 100 ppb range)
Temperature: 5℃ to 99℃
Pressure: 0.03 MPa to 0.50 MPa,
Pressure fluctuation: within ±0.05 MPa (within the specified pressure range)
Flow rate: 20 mL/min to 200 mL/min
Environmental conditionsTemperature: 5℃ to 40℃
Relative humidity: less than 85%
InstallationInstall place: indoor
Display functionLCD (with a back light) TOC, conductivity, water temperature, alarm
Power100 V to 240 V AC ±10%, 50 Hz/60 Hz built-in fuse 250 V AC 3.15 A (T)
Power consumption80 VA (max.)
Outside dimension300 (W) × 400 (H) × 165 (D) mm
Mass13 kg
Concerned directivesCE markingEMC Directive: EN61326-2-3
Low Voltage Directive: EN61010-1
RoHS Directive: EN50581
FCC RuleFCC parts 15
Protection structureIP 43 (IEC60529, JIS C0920)
Pollution level 2 (IEC61010-1)

Request for Information

Do you have any questions or requests? Use this form to contact our specialists.

* These fields are mandatory.

Related products

CS-100 Series
CS-100 Series

Stand-alone Type Chemical Concentration Monitor

CS-100F1 Series
CS-100F1 Series

Fiber Optic Type Chemical Solution Concentration Monitor

CS-600F
CS-600F

Fiber Optic Type Chemical Concentration Monitor

CS-620F
CS-620F

Optical Fiber Type Hot Phosphoric Acid Concentration Monitor

CS-700
CS-700

High Precision, High Stability Chemical Concentration Monitor

CS-900
CS-900

Non-Contact Chemical Concentration Monitor

HZ-960
HZ-960

Dissolved Ozone Monitor

ICP Neo
ICP Neo

ICP Software

OPSA-150
OPSA-150

Organic pollutant monitor

SLIA-5000
SLIA-5000

Silica analyzer

TOCADERO ONE
TOCADERO ONE

Automatic Total Organic Carbon Analyzer (On-line TOC analyzer)

TPNA-500
TPNA-500

Automatic total nitrogen/phosphorus monitor

Ultima Expert LT
Ultima Expert LT

Affordable high performance ICP-OES

300-NO3-C Nitrate Ion Sensor Cartridge
300-NO3-C Nitrate Ion Sensor Cartridge

Nitrate Ion Sensor Cartridge

H-1 Series
H-1 Series

Field-installation type water quality measuring instruments

HD-200
HD-200

Field-installation type dissolved oxygen meter (DO meter)

HD-300
HD-300

Field-installation type dissolved oxygen meter (DO meter)

HD-480
HD-480

Panel-mount type dissolved oxygen meter (DO meter)

HE-200C
HE-200C

Field-installation type electric conductivity meter (conductivity meter)

HE-200H
HE-200H

Field-installation type electric conductivity meter

HE-200R
HE-200R

Field-installation type electric resistivity meter (resistivity meter)

HE-300C
HE-300C

Field-installation type electrical conductivity meter (conductivity meter)

HE-300R
HE-300R

Field-installation type electric resistivity meter (resistivity meter)

HE-480C
HE-480C

Panel-mount type conductivity meter (conductivity meter)

HE-480H
HE-480H

Panel-mount type conductivity meter (conductivity meter)

HE-480R
HE-480R

Panel-mount type resistivity meter (resistivity meter)

HE-960CW
HE-960CW

Panel-mount type 2-channel conductivity meter (conductivity meter)

HE-960HI
HE-960HI

Panel-mount type conductivity meter

HE-960RW
HE-960RW

Panel-mount type 2-channel electric resistivity meter (resistivity meter)

HO-200
HO-200

Field-installation type ORP meter

HO-300
HO-300

Field-installation type ORP meter

HR-480
HR-480

Panel-mount type galvanic residual chlorine meter

LAQUA DO2000
LAQUA DO2000

Benchtop DO/BOD/Temperature Meter

LAQUA DO210
LAQUA DO210

Handheld Dissolved Oxygen/Temperature Meter

LAQUA DO220
LAQUA DO220

Handheld Dissolved Oxygen/Temperature Meter

LAQUA DS-72
LAQUA DS-72

Benchtop Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUA EC2000
LAQUA EC2000

Benchtop Conductivity/Resistivity/Salinity/Total Dissolved Solids/Temperature Meter

LAQUA EC210
LAQUA EC210

Handheld Conductivity/Resistivity/Salinity/Total Dissolved Solids/Temperature Meter

LAQUA EC220
LAQUA EC220

Handheld Conductivity/Resistivity/Salinity/Total Dissolved Solids/Temperature Meter

LAQUA F-74
LAQUA F-74

Benchtop pH/ORP/Ion/Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUA PC2000
LAQUA PC2000

Benchtop pH/ORP/Ion/Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUA PD2000
LAQUA PD2000

Benchtop pH/ORP/Ion/DO/BOD/Temperature Meter

LAQUA PH2000
LAQUA PH2000

Benchtop pH/ORP/Temperature Meter

LAQUAtwin F-11
LAQUAtwin F-11

Pocket Water Quality Meters

LAQUAtwin ORP-11
LAQUAtwin ORP-11

Pocket Water Quality Meters