MEXA-2000SPCS series

Solid Particle Counting System

MEXA-2000SPCS - Solid Particle Counting System
MEXA-2000SPCS - Engine Vehicle Certification TestingMEXA-2000SPCS - Partial Flow Dilution Tunnel

The HORIBA MEXA-2000SPCS series measures the number of solid particles from engine exhaust gas in real-time.
The series can complete engine/vehicle certification testing in the latest regulations*1, such as Euro 6/VI and China 6/VI,along with R&D testing of engines and particulate filters by direct sampling without dilution.

*1: Please contact us for more information on the regulations that the products comply with.

Line-ups

  • Certification tests for the latest regulations
    MEXA-2000 / 2200SPCS
  • R&D tests with high pressure direct sampling  
    MEXA-2100 / 2300SPCS
  • SPN10 particle measurement [New Lineup]  
    (Fulfills GTR No.15, Amendment 6, SPN 10 requirements)  
    MEXA-2010/2110/2210/2310SPCS

 

Sampling methods
ModelsMEXA-2000SPCS
MEXA-2010SPCS
MEXA-210SPCS
MEXA-2110SPCS
MEXA-2200SPCS
MEXA-2210SPCS
MEXA-2300SPCS
MEXA-2310SPCS
Sampling methodFull Flow TunnelFull Flow Tunnel
Direct Sampling
Full Flow Tunnel
Partial Flow Tunnel
Full Flow Tunnel
Direct Sampling
Partial Flow Tunnel

Features

  • Compact design

• Easy to install and transport in a laboratory
• Small footprint 

        
     
       
 
  • High performance sampling system

The set DF is not affected by changes in sample pressure in the CVS or
sampling system. The VPR *1 calibration factor (PCRF *2) can be used
for many applications without specific calibration/correction of the diluters
in VPR.
*1 VPR: Volatile Particle Remover
*2 PCRF: Particle Concentration Reduction Factor

  • Various optional units

The combination of the main unit and optional units allows a wide range of applications and sampling configurations.

 For Measurement
Optional UnitsFunctions2000210022002300
Cyclone Unit (CYU) *1External Cyclone○Built-in○Built-in
Sample Return Unit (SRU)Returning sample to CVS○×××
Cooler Unit (CLU) *2Cooling detector (CPC) for high temperature conditions○○○○

For Performance Check
Optional UnitsFunctions2000210022002300
Dilution Factor Checker (DFC)Dilution factor check and flow rate calibration○○○○
Linearity Check Unit (LCU)Generating solid particles for linearity check
and penetration efficiency check
○○○○
Volatile-particle Generation Unit (VGU)Generating particles for removal efficiency
check of evaporation tube
○○○○

*1: For MEXA-2000/2200SPCS, select a hatted probe or an external cyclone unit set at full flow tunnel side.
*2: Mounted in an optional 19-inch cabinet with main unit.

  • High accuracy dilution

Reliable diluter developed by HORIBA Group
  Patent number: 7201071(US)

  • Dedicated particle number counting

Fully integrated system for stand-alone operation with the comprehensive
data logging functions. Also available for operation with host CPU control
using the AK-LAN host interface.

ModelsMEXA-2000SPCSMEXA-2100SPCSMEXA-2200SPCSMEXA-2300SPCS
Complying Regulations*1GTR No.15,
Amendment 6
Euro 6, Euro VI,
Stage V (NRMM),
China 6, China VI,
Bharat Stage VI (LDV/HDV)
-GTR No.15,
Amendment 6
Euro 6, Euro VI,
Stage V (NRMM),
China 6, China VI,
Bharat Stage VI (LDV/HDV)
-*2
Measuring principleLaser scattering condensation particle counting (CPC)
Lower particle size limitCounting efficiency of 23 nm particles: 50 % ±12 %, Counting efficiency of 41 nm particles: >90 %
Measuring components and rangeNumber concentration of solid particles; 0 – 10000 up to 0 – 50000 particles/cm3 (after internal dilution) *3
Sample handling temperature52 °C or less (Dilute sampling)Maximum permissive temperature
(Direct sampling) 350 °C *4
52 °C or less (Dilute sampling)Maximum permissive temperature
(Direct sampling) 350 °C *4 
Diluted sample temperaturePrimary diluter (PND1):
191 °C ± 10 °C
Evaporation tube (ET):
350 °C ± 10 °C
Secondary diluter (PND2):
< 35 °C (at inlet of CPC)
Pre-classifier: 47 °C ± 5 °C
Primary diluter (PND1):
191 °C ± 10 °C
Evaporation tube (ET):
350 °C ± 10 °C
Secondary diluter (PND2):
< 35 °C (at inlet of CPC)
Primary diluter (PND1):
191 °C ± 10 °C
Evaporation tube (ET):
350 °C ± 10 °C
Secondary diluter (PND2):
< 35 °C (at inlet of CPC)
Pre-classifier: 47 °C ± 5 °C
Primary diluter (PND1):
191 °C ± 10 °C
Evaporation tube (ET):
350 °C ± 10 °C
Secondary diluter (PND2):
< 35 °C (at inlet of CPC)
Dilution factors in diluters Primary diluter (PND1):
10 to 200 *3
Secondary diluter (PND2): 15
Diluter in DSU: 10
Primary diluter (PND1):
10 to 200 *3
Secondary diluter (PND2): 15
Primary diluter (PND1):
10 to 200 *3
Secondary diluter (PND2): 15
Diluter in DSU: 10
Primary diluter (PND1):
10 to 200 *3
Secondary diluter (PND2): 15
PCRF0.95 < fr (30 nm) / fr (100 nm) < 1.3, 0.95 < fr (50 nm) / fr (100 nm) < 1.2
Volatile particle removal efficiency>99.0%, for C40 (30 nm of particle size, and 10000 particles/cm3 or more)
Accuracy of dilution factorWithin ± 10 % of nominal dilution factor setting (for VPR total dilution factor of 150 to 3000, gas based) *5
Operating environmentWithout CLU (standard): Ambient temperature: 5 °C to 30 °C, Ambient humidity: 80 % or less as relative humidity
With CLU (optional): Ambient temperature: 5 °C to 45 °C, Ambient humidity: 80 % or less as relative humidity
Power supply voltage and frequency200/220/230/240 V AC (±10 %, max. 250 V), 50/60Hz (±1.0 Hz), single phase (to be specified at ordering)
Power requirementsMain unit: Max. 2.3 kVA
Main unit and all optional units: Max. 4.5 kVA
Main unit: Max. 2.5 kVA
Main unit and all optional units: Max. 4.4 kVA
Main unit: Max. 2.4 kVA
Main unit and all optional units: Max. 4.3 kVA
Main unit: Max. 2.6 kVA
Main unit and all optional units: Max. 4.5 kVA
Dimensions (excluding any projections) /Mass  
Main unit
(without transfer tube, control unit and optional units)
434(W)×731(D)×637(H) mm
Approx. 115 kg
434(W)×845(D)×637(H) mm
Approx. 120 kg
434(W)×910(D)×637(H) mm
Approx. 140kg
434(W)×910(D)×637(H) mm
Approx. 145 kg
Optional units                                        CYU: Approx. 290(W)×146(D)× 236(H) mm *6 Approx. 4 kg
                                        SRU: Approx. 300(W)×550(D)× 450(H) mm Approx. 35 kg
                                        CLU: Approx. 570(W)×850(D)×1227(H) mm Approx. 80 kg (for CLU and optional cabinet)
                                        DFC: Approx. 464(W)×550(D)× 320(H) mm Approx. 38 kg
                                        LCU: Approx. 350(W)×690(D)× 670(H) mm Approx. 35 kg
                                        VGU: Approx. 550(W)×300(D)× 450(H) mm Approx. 20 kg 


*1: Please contact us for more information on the regulations that the products comply with.
*2: MEXA-2300SPCS can be used in the measurement method according to the regulation. For detailed information, please contact HORIBA.
*3: Dilution factor of the system should be determined so that the particle concentration after dilution fits into the measuring range.
*4: Allowable range of gas temperature at sample probe inlet depends on the sampling condition, because it is limited as the temperature of diluter in DSU (350 °C or less). For detailed information, please contact HORIBA.
*5: Accuracy of dilution factor check with span gas.
*6: The dimensions depend on customers.

Brake Dust Measurement
Automotive Manufacturing

Brake Dust Measurement

A series of legislative measures has significantly reduced the amount of emissions that is being emitted by internal combustion engines of light and medium-duty vehicles.

Explore application
Sub-23nm Particle Measurement
Automotive Manufacturing

Particle Measurement in the Sub-23nm Range

Concerns exist that advances in modern engine technology may contribute to large portions of solid particles at sizes smaller than 23nm. The EU Joint Research Center has confirmed this concern in several investigations.

Explore application
MEXA-2000SPCS Brochure English

MEXA-2000SPCS Brochure English

1.59 MBPDF

Request for Information

Do you have any questions or requests? Use this form to contact our specialists.

* These fields are mandatory.