UV-visible spectroscopy
- 2048 pixels high resolution spectrograph scanning wavelengths from 180 nm to 750 nm is the master part of the UV500-Compact. Direct absorbance measurement for UV254, COD, BOD, TOC, NO3, Colour PO4 and Cr VI brings fast and stable measurements with a simple hydraulic circuit. Factory predefined or local multi-point calibration allows to get readings of COD, BOD and TOC under the UV alternative method for compatible applications. UV spectroscopy brings faster results than conventional methods like COD, BOD, TOC with much less maintenance once the correlation is dertermined.
- The patented flow cell allows very high level of suspended solid without clogging. The turbidity is automatically compensated by a dual-wavelength method.
- The UV source is a xenon flash lamp specified for 10^9 flashes that corresponds to more than 10 years of life time with one measurement every minute.
- Physico-chemical measurements like pH, ORP, dissolved oxygen, conductivity can be added to the internal measurements by using external probes. The dissolved oxygen probe is based on fluorescence method for a lower maintenance and higher stability.

Measuring principle by absorbance
1 : spectrograph,
2 : beam splitter,
3 : patented water flow cell,
4 : xenon lamps

UV fluorescence principle
1 : Xenon lamp,
2 : excitation filter,
3 : flow cell,
4 : emission filter,
5 : photomultiplier,
6 : reference photo detector

Laser diode turbidity principal (nephelometric)
1 : Laser diode (650 nm or 850 nm),
2 : flow cell,
3 : Photo detector

Patented flow cell
1 : Allows very high level of suspended solid without clogging for all the optical measurements making it suitable for industrial & municipal waste water application.
- The patented flow cell allows very high level of suspended solid without clogging for all the optical measurements making it suitable for industrial and municipal waste water application. The turbidity is automatically compensated by a dual-wavelength method.
- Suitable for sample with high chloride content
- Wetted parts of flow cell make it suitable for most corrosive sample
Robust industrial probes
All the probes are specially designed for harsh environments with high level of suspended solid.
ORP/pH probe

Dissolved oxygen probe

pH differential probe

Total suspended solid probe

Turbidity probe

Conductivity probe

User-friendly interface
The colour touch screen and intuitive interface available in 9 different languages (Chinese, English, French, German, Hungarian, Italian, Portuguese, Spanish, Turkish) makes very easy to test or configure the analyser. Many test functions allows to test and troubleshoot each element of the analysers (light signal, pumps, solenoid valves, etc...) to setup quickly a maintenance diagnostic. An acid resistant protection film on the screen assumes an efficient long term protection.
Communication

The RS232 port supports the MODBUS protocol to transmit each Standard channel value to a SCADA system. Additional parameters are available like status code, error code, calibration values and pumps run time. Basic 4-20 mA output modules can be plugged on the main board for each Standard channel, in the limit of 12 modules. A USB port enables to download on any USB key the last 5000 recorded measurements as well as a diagnostic file containing the configuration and useful information for remote troubleshooting.The recorded measurements file can be imported to Excel for graphs or other treatments. The software of the analyser can be upgraded by connecting a USB key. A USB port enables to download on any USB key the last 5000 recorded measurements as well as a diagnostic file containing the configuration and useful information for remote troubleshooting.The recorded measurements file can be imported to Excel for graphs or other treatments. The software of the analyser can be upgraded by connecting a USB key.
Multiplexing system
When different streams need to be analysed, for example inlet and outlet of a plant, an optional multiplexing system delivers relay contacts to control external electric-valves or external pumps.
Up to 6 different streams can be selected
The Standard channels can be either duplicated (each one having its own 4-20mA output or MODBUS register), or measured sequentially to fit with the maximum of 16 Standard channels (a MODBUS register tells which stream is currently being measured).
Sampling system
The UV500-Compact can adapt to many different kind of sampling depending of the application : surface water, drinking water, process water or wastewater.
If the water is already pressurized, the sample can be admitted directly inside the analyser with a maximal pressure of 4 bars. Otherwise an optional built-in peristaltic pump, synchronised with the measurement to extend the tubing life time, allows to take the sample directly from a tank located up to 6 meters below the analyser. For demanding applications with long distances, another peristaltic pump in a separate enclosure is proposed as an option. For some applications on river water or wastewater where two sampling pumps are necessary, the UV500-Compact delivers a relay contact to synchronise the primary pump. The delay and running time of each pump can be adjusted easily in the parameters menu of the analyser.