| Product name | Laser scanning type surface oil detector |
|---|
| Model number | LO-300 |
|---|
| Subject of detection | Oil on water surface or liquid on floor |
|---|
| Detection method | Surface scanning laser/reflected light sensor |
|---|
| Detection distance | 0.3 m to 4 m (Piezometric surface Max.6 m) |
|---|
| Laser emitter | Semiconductor laser, wavelength (λ) 650 nm, within 1 mW output (Class 2) |
|---|
| Modulation laser freq | About 50 kHz |
|---|
| Scanning Mechanical | Oscillation mirror |
|---|
| Leak detection | Leak detection alert | When the state to exceed a set level of “Oil WARNING” or “OIL ALARM” passes longer than “CONT.TIME SET.”, it judges alert. |
|---|
| System Error | Malfunction | Engages when Temp., laser emission, laser scanning, motor rotation or power fails. |
|---|
| Abnormal light sensing | Engages when Upper light reception level, Lower light reception level, floating debris produces no reflection or abnormally strong reflection. |
| Contact output | Number of outputs | 2 |
|---|
| Output type | No-voltage contact output |
| Contact type | Relay contact; SPDT(1c) |
| Output capacity | 250 V AC 4 A,30 V DC 4 A |
| Output 1 | AL (Oil Alarm) | When “OIL ALARM” is detected, it operates. |
| Output 2 | ER (System Error) | When “System Error” is detected, it operates. |
| Transmission output | Number of outputs | 1 |
|---|
| Output type | 4 mA to 20 mA DC (Isolator) |
| Load resistance | Max. 550 Ω |
| Setting and Indication | (Indication) | Status of water surface | NORMAL RUN |
|---|
| OIL WARNING |
| OIL ALARM |
| HIGH LEVEL |
| LOW LEVEL |
| SYSTEM ERROR |
| Light reception level | 4 mA to 20 mA is transformed converted into Level bar of 17 Step. |
| Surface Oil area | 0% to 100% is transformed converted into Level bar of 10 Step. |
| LOG | Max. 100 points Alarm history |
| (Setting) | OIL LEVEL | Adjustment: 4 mA to 20 mA (1 mA carving) Indication: red △ marker under LEVEL bar |
|---|
| AREA LEVEL | Adjustment: 0% to 90% (10% carving) Indication: △ marker under AREA bar Oil warning: Yellow △ Oil alarm: Red △ |
| CONT.TIME | Adjustment: 0 seconds to 999 seconds (1 second carving) |
| RELAY OUT (AL) | Adjustment: MODE: Select of Oil warning or Oil Alarm TIME : 0 seconds to 99 seconds, ∞(infinity) |
| LEVEL ERR. | Adjustment: “ON” or “OFF” |
| MULTI-TRANS | Adjustment: “ON” or “OFF” |
| OVER LEVEL | Adjustment: 4 mA to 24 mA |
| DATE | Adjustment: Year/Month/Day/Hour/Minute |
| CONTRAST | Adjustment: CONTRAST LEVEL of LCD |
| COLOR | Adjustment: COLOR of LCD |
| FACTORY | Adjustment: at the time of shipment from the factory |
Laser replacement Contact output time setting | Adjustment: 0:00 to 23:59 (unit 1 minute) |
| Power supply | Power range | 100 V AC ±10% 50/60 Hz |
|---|
| Power consumption | 100 W less than |
| Other | With time-lag fuse (125 V 2 A) |
| Operating temperature range | −10℃ to +50℃ (without freeze) |
|---|
| Operating humidity range | Relative humidity: 5% to 95% (without condensation) |
|---|
| Compatible standards | CE marking | EMC Directive: EN61326-1 |
|---|
| Low-voltage Directive: EN61010-1, EN60825-1 |
| Structure | Installation | Outdoor installation type |
|---|
| Protection code | IP66 corresponding |
| Material | Detection part | AL (Chromate processing after urethane painting) |
Setting and Indication part | AL (Alumite processing after urethane painting) |
| Paint color | U35-85B (Edition U of JPMA) |
| External dimensions | φ185 mm × H547 mm |
|---|
| Mass | Main body: Approx. 11 kg; Cables: Approx. 1.4 kg |
|---|
| Installation condition | Installation inclination: less ±3° It avoids direct sunlight and it sets it up. Frozen provisions of the surface of the water of detection are necessary. The rain avoiding provisions are necessary. |
|---|
| Attached cable | Power cable | 1 cable (Length:5 m NA6UCL AWG16 × 3 cores (outer diameter φ10.4)) |
|---|
| Signal cable | 1 cable (Length:5 m NA3VCSB AWG21 (0.5 sq) × 8 cores with shield (outer diameter φ8.5)) |