PM-960, PM-100

PM-960

Peracetic acid concentration monitor

Continuous measurement of peracetic acid concentration for food filling machines.

PM-960 / PM-100 are measurement devices used to continuously measure the concentration of peracetic acid, which is utilized for sterilization in beverage and food processing. Reagents are not required and maintenance is easy.

PAA

Division: Process Water
Manufacturing Company: HORIBA Advanced Techno Co., Ltd.

Compatible with a wide range of measurement

Measurements of concentrations ranging from 100 to 4000 ppm are possible.

Continuous measurement is possible

Continuous measurement of concentration becomes possible when the sample water is supplied at a constant flow rate of 500-2000 mL/min and a pressure below 0.1 MPa.

High maintainability

Sensor replacement is simple. From sensor replacement to calibration, intuitive operation is possible. No reagents are required.

Remote operation is possible

Operation from a remote location using a panel-mounted display unit is possible. Equipped with a 4-20mA output and RS-485 communication, it has 5 contact outputs.

Converter

Product nameConverter for peracetic acid monitor※1
ModelPM-960
Temperature compensation elementPlatinum resistance thermometer (Pt1000) 1000 W at 0℃, 3850 ppm/℃
Measurement range100 to 4000ppm (0.010 to 0.400%)
Repeatability±100ppm
Transmission outputNumber of outputs: 2 (Negative terminals of each transmission output channel are connected inside and thus have the same electric potential.) 4mA to 20mA DC or 0mA to 20mA DC input/output isolated type Load resistance: 900  (max.) Linearity: Within 0.08 mA (Output only) Repeatability: Within 0.02 mA (Output only) Output setting: Peracetic acid concentration (Selectable from 0 to 22000 ppm or 0.000 to 2.200) Temperature (Selectable from 10C to 110C) HOLD function: Selectable from the previous value hold and the optional value hold (Setable without HOLD only while calibration
Contact outputNumber of outputs: 5 Contact output: 4 (R1 to R4) Contact type: Non-voltage contact output, relay contact SPST (1a) Contact capacity: 240 V AC 1 A, 30 V DC 1 A (Resistance load) Contact function: Selectable from Upper/lower limit alarm (ON/OFF control) at each measuring objects(concentration, temperature) (Alarm Setting of delay time about measuring objects: 0 seconds to 600 seconds) Contact action: closed when status is in the event. (However, R1 to R3 share a common terminal. R4 and RF share a common terminal) Error alarm contact output (RF): 1 Contact type: Non-voltage contact output, Relay contact, SPDT (1c) Contact capacity: 240 V AC 1 A, 30 V DC 1 A (Resistance load) Contact function: Fail Contact action: Closed when status is normal for C-NO output. Opened when any erroneous status is detected or power is down for C-NO output. C-NC output is opposite action of C-NO. R4 and RF share a common terminal.
Contact inputNumber of input: 1 (external HOLD input) Contact type: No-voltage a contact for open collector Condition: ON resistance: 100 ・ (max.)
・Open-circuit voltage: 24 V DC
・Short-circuit current: 12 mA DC (max.)
Communication outputRS-485 input/output
Self-diagnosis functionCalibration error /Temperture sensor error/Meter error
Power supply24 V DC ±10%
StructureIndoor-use panel installation type Panel case: ABS, Terminal: PBT Panel: IP65 dust and water proof structure
Conforming standardsCE Marking EMC Directive: EN61326-1※2 Class A, Industrial electromagnetic environment FCC rule FCC Part15

Sensor

Product namePeracetic acid sensor※3
Model5800
Measurement principleElectrochemical measurement system
Measurement targetPeracetic acid (CH3COOOH) ※4
Sample temperature range0℃to 45℃ (without freezing)
Supply flow rate500 mL/min to 2000 mL/min※5
PressureWithin 0.1 MPa (constant)※6
Responsibility(To the measurement cell after a supply start) T90 < 5 min※5
Repeatability±100 ppm※7
Ambient temperature0℃ to 45
Liquid contact materialPVC, PTFE, Silicon, PPO, OPP
Internal liquidNeutral phosphate(Food additive)
Cable length5 m to 50 m max.※8

※1 This product does not use for medical equipment.
※2 When the sensor cable, the transmission cable, or the contact input cable is extended to 30 m or longer, the surge test specified in the EMC directive for CE marking is not applied.
※3 This product does not use for medical equipment.
※4 Measurements may be affected by a change of the concentrations of hydrogen peroxide
※5 When supply flow rate decreases, responsibility may become slow. Supply flow rate is responsibility when switches from the solution including peracetic acid from the solution which does not include peracetic acid.
※6 When sample pressure includes a change, influence is reflected on instructions level. Install it to become the constant pressure.
※7 Under the constant ambient temperature, sample temperature and flow rate
※8 When the connection cable is extended to 30 m or longer, the surge test specified in the EMC directive for CE marking is not applied.

 