Aqualog - Environmental Water Research Analyzer

Aqualog-Environmental Water Research Analyzer

The Gold Standard for Water CDOM Research

Not just a scanning fluorometer for EEMs, but a much faster and better A-TEEM spectrometer for colored dissolved organic matter (CDOM)

The HORIBA Aqualog is a unique optical spectrometer that is the gold standard in environmental water research around the world for the study of color dissolved organic matter (CDOM).

The Aqualog was invented to meet the needs of environmental water researchers around the world studying CDOM using fluorescence spectroscopy. At that time researchers were using scanning spectrofluorometers to slowly acquire a three dimensional matrix of the fluorescence excitation and fluorescence emission spectra, called an Excitation Emission Matrix (EEM). The EEM provides a fingerprint for studying dissolved organic matter, however it took up to an hour to collect a single EEM profile, tying the researcher to the lab bench for the entire day. The HORIBA Aqualog vastly improves the speed with which fluorescence EEMs are collected, dramatically increase the dynamic range across which EEM fingerprints are quantitative, and simultaneously acquires absorbance spectra for absorbance and color analysis of non-fluorescent molecules present in water. We call this technique that the Aqualog employs, an Absorbance-Transmission Excitation Emission Matrix, or A-TEEMTM.

Today the Aqualog is used in some of the most prestigious water research labs, and remote locations, to study a variety of important research topics.

Hot Environmental Research Topics for Color Dissolved Organic Matter (CDOM) and its derivatives DOM, and NOM

 

ASTM D8431 Standard Test Method for Detection of Water-soluble Petroleum Oils (BTEX) by A-TEEM Optical Spectroscopy and Multivariate Analysis.

   Science in Action Series   Spectroscopy Matters Series

Segment: Scientific
Manufacturing Company: HORIBA Scientific

Featured Videos

Webinar: Integrated Characterization of Organic Matter for Water Treatment Optimization

Google “Positive Current | SEARCH ON” on YouTube

Global warming causing Canada's permafrost to release ancient bacteria

Life in the Arctic with the Aqualog was created entirely by our customer who wanted to record her experience transitioning from a scanning fluorometer to the Aqualog for water research. She is solely responsible for its content.

Aqualog A-TEEM compared to traditional scanning PMT fluorometers

Traditional scanning spectrofluorometers have been used to collect a molecular fingerprint, in the form of a fluorescence excitation emission matrix, or EEM. Sometimes also referred to as 3D Fluorescence, an EEM is a three-dimensional data set of fluorescence excitation wavelength versus fluorescence emission wavelength versus fluorescence intensity. With a scanning spectrofluorometer, this data set is acquired by sequentially scanning a series of emission spectra, at varying excitation wavelengths, and then reconstructing the resultant data set three dimensionally. This three-dimensional data set can be used with third party multivariate analysis software for component analysis, as is done with other analytical techniques such as FTIR, HPLC and MS. There are, in fact, many scientific papers published citing the use of scanning spectrofluorometers for fluorescence EEM component analysis in many disciplines including food sciences, water research and pharmaceuticals.

There are, however, two fundamental limitations of using a traditional scanning PMT fluorometer for EEM component studies. The first is that it takes a very long time to collect a single EEM with a scanning fluorometer. Depending on the brightness of the signal, and the wavelength range and resolution that is required, a single EEM experiment can take a scanning spectrofluorometer up to an hour to collect!

Another important limitation of scanning fluorometers is that the shape of the fluorescence EEM fingerprint itself can change with even subtle variations in sample concentration. If an instrument measures different EEM fingerprints for the same molecule at different concentrations, it really can’t be used for component analysis. For an EEM to be used as a true analytical technique, the shape of the spectra must be independent of concentration.

These two inherent limitations of a scanning spectrofluorometer have impacted the usability of the fluorescence EEM technique, and this has lead to the development by HORIBA of the A-TEEM technique.

HORIBA’s unique A-TEEM technique overcomes these two limitations. With CCD detection technology, HORIBA solves the serious speed limitations of scanning spectrofluorometers because with HORIBA technology, an entire fluorescence EEM can be acquired in mere seconds to minutes depending on the sample.

Figure 1. Three dimensional contour plot viewed at an angle of a fluorescence EEM, with three dimensional axis for fluorescence excitation, emission and intensity.

Figure 2. Contour plot (top down view) of fluorescence EEM of fluorescein acquired in one second with Duetta.

HORIBA has also solved the problems associated with the fluorescence inner filter effect by taking advantage of the fact that the A-TEEM technique also collects absorbance of the same sample at the same time as the fluorescence, and uses the absorbance to correct EEMs for the inner filter effect (IFE).

HORIBA calls this technique A-TEEMTM, for Absorbance-Transmission Excitation Emission Matrix. By correcting for inner filter effects, the A-TEEM molecular fingerprint is a much more absolute representation of the true molecular fingerprint.  Therefore when  using third party multivariate chemometrics analysis software, the A-TEEM data provides much more robust component analysis than can be achieved with just a simple EEM from a scanning fluorometer.

Below is a good example to show how even a small concentration difference in a single molecule can have a significant effect on the shape of an EEM fingerprint, but with proper IFE correction an A-TEEM fingerprint remains the same.

Figure 3. Fluorescence Excitation Emission Matrices of two concentrations of quinine sulfate in tonic water diluted in 0.1 M perchloric acid (aq.) with and without inner-filter effect corrections applied. Acquired with HORIBA Duetta.

Aqualog A-TEEM chemometrics analysis presented here are derived from Eigenvector Research Incorporated, Solo software.


Additional Resources

USGS Procedures for using the Horiba Scientific Aqualog® fluorometer to measure absorbance and fluorescence from dissolved organic matter https://pubs.er.usgs.gov/publication/ofr20181096

Aqualog CDOM Publication Links

Click below to view the Aqualog CDOM publications from the scientfic community. Results may vary depending on which search engine you use.

            


Hardware

  • The only true simultaneous absorbance-fluorescence system available
  • TE-cooled CCD fluorescence emission detector for rapid data acquisition up to 100 times faster than any other benchtop fluorometer
  • Corrected UV-VIS absorbance detection path for stability and accuracy
  • Double grating excitation monochromator for superior stray light rejection
  • Matching bandpass for absorbance and fluorescence spectra
  • Automatic sample changer option (2 or 4 position)
  • Compatible with flow cells and titrator

Software

  • Optimized experiment set-up menus minimize user configuration time
  • Complete NIST-traceable corrected fluorescence spectra automatically generated
  • Spectral and kinetic analysis tools for both absorbance and fluorescence data
  • Methods and batch protocols for automating multiple sample measurement

NEW A-TEEM™ technology

A-TEEM technology uses absorbance, transmittance and EEM data to fingerprint molecules with high specificity and ultrahigh-sensitivity at a 6 million nm/min emission scan rate!

All colored molecules exhibit unique molecular absorbance and transmittance spectra; many colored molecules also exhibit unique fluorescence excitation and emission spectra that can be measured as an excitation-emission matrix (EEM). Simultaneously combining Absorbance–Transmission and EEM is a new technique (A-TEEM) that provides a distinct molecular fingerprint with numerous potential applications.

Aqualog combines an ultrafast CCD that’s up to 4,000 times faster than traditional PMT-based fluorometers, with our new A-TEEM technology so you can easily and effectively identify, quantify and understand individual organic compounds in complex mixtures in minutes. A-TEEM has already proven in many cases to be more effective in protein, vaccine, wine and water research, quality and process applications than HPLC and vibrational spectroscopy.


NEW Aqualog® Datastream Dashboard

Features

  • Seamless integration with Aqualog
  • Convenient HTML-based interface
  • Push-button method operation
  • Simple administrator level controls for calibration and method development


Benefits

  • Easy access through internet or intranet
  • Dashboard shows the latest readings, time series and tables for trends and analysis
  • WTP can upload their own independent data

 

 

Aqualog Datastream Dashboard is powered by Solo_Predictor software from Eigenvector Research, Incorporated

 


NEW HORIBA Multi-Model Predictor Tool

HORIBA Instruments is pleased to introduce a new software tool designed to automate multivariate and machine learning analysis workflows for industrial QC/QA applications of HORIBA’s patented Aqualog Absorbance- Transmission fluorescence Excitation Emission Matrix (A-TEEM™) spectrometer.

Key Applications of HMMP Tool

  • Wine and Grape Quality Chemistry (phenolics, anthocyanins, tannins, sulfites etc..)
  • Water Contamination (oil, algae and other materials)
  • Grain mold and odor compounds
  • Cannabinoids
  • Pharmaceuticals (Drugs, Vaccines, Cell Media)
  • Olive Oil adulteration and spoilage
  • Dietary supplement adulteration

 

Key Features and Benefits

  • Easy, Rapid Operator Level Analysis
  • Facilitated Administration of Method Model Development and Editing
  • Complete Parameter Profile and Classification Reports
  • Compatible with Laboratory Information Management Systems
  • HMMP Add-In Fully Integrated into Eigenvector Inc. Solo/Solo+Mia and Exclusively Activated and Supported by HORIBA Instruments Inc.

NEW Automatic Sipper Accessory

New for our Aqualog®  A-TEEM™ spectrometer, the Aqualog automatic sipper accessory handles sampling from a single source, in addition to dispensing rinsing solutions, detergents and controlling reverse-flow drainage The 4-sample changer unitconnects to the main sipper unit to enable sampling of up to 4 sources.

The sipper offers convenient installation and operation, with built-in automatic cleaning, leak detection and protection. It is fully integrated into the new Aqualog 4.0 software for batch analysis and has a variety of uses in water, pharmaceutical, beverage phenolics and many other applications.

When used at a water treatment plant, the sipper and four channel accessory enable the Aqualog to automatically extract and monitor raw, settled and finished water samples. Each sample changer unit is compatible with overflow and filtration devices, serving up to 4 independent water treatment plant sources.


NEW Fast-01 Autosampler Accessory

The Fast-01 can be configured to use a variety of sample-vials and racks to meet your application needs and enables complete temperature control. Sample vial repeats and injection volumes are easily facilitated with the Aqualog 4.2+ software, which also offers preconfigured blank files. 

All data files can be exported with ISO-formatted time-date stamping and user-configurable Sample ID and repeat codes.

All aspects of the Fast-01 hardware control are at your fingertips, with key real-time access features to facilitate the configuration and execution of your batch experiments, as well as priming, cleaning and maintenance.

Fluorescence Hardware

Light source

Extended-UV: 150W vertically mounted xenon arc lamp

Excitation range

200 nm to upper limit of emission detector

Excitation bandpass

5 nm

Excitation monochromator

Subtractive double monochromator

Excitation gratings

1200 gr/mm, 250 nm blaze

Excitation wavelength accuracy

±1 nm

Choice of Detector

Red-extended

Emission range

250-800 nm

Emission grating

285 gr/mm; 350 nm blaze

Hardware pixel binning

0.58, 1.16, 2.32, 4.64 nm/pixel

Emission bandpass

5 nm

Emission spectrograph

Fixed, aberration-corrected 140 mm focal length

Emission detector

TE-cooled back-illuminated CCD

Emission integration time

5 ms minimum

CCD gain options

2.25 e-/cts in high gain, 4.5 e-/cts in medium gain, 9 e-/cts in low gain

Sensitivity

Water-Raman SNR > 20,000:1 (RMS method) (350 nm excitation, 30s integration)

Weight

32.72 kg (72 lbs)

Dimensions

LWH (618 x 435 x 336 mm); (24" x 17" x 13")

 

Absorbance Hardware

Scanning range

200-800 nm (UV lamp)

Bandpass

5 nm

Slew speed

Maximum 500 nm/s
Optical systemCorrected single-beam
DetectorSi photodiode

Wavelength accuracy

+/- 1 nm

Wavelength repeatability

+/- 0.5

Photometric accuracy

+/- 0.01 AU from 0 to 2 AU
Photometric stability<0.002 AU per hour
Photometric repeatability+/- 0.002 AU (0 to 1 AU)

Stray light

<1% measure with Kl standard

Trihalomethane Speciation Modeling in Drinking Water Using the A-TEEM Spectroscopic Technique and Multivariate Data Analysis
Trihalomethane Speciation Modeling in Drinking Water Using the A-TEEM Spectroscopic Technique and Multivariate Data Analysis
This application note describes a rapid, sensitive nondestructive disinfection byproducts (DBP) prediction method using patented simultaneous Absorbance-Transmittance and fluorescence Excitation-Emission Matrix (A-TEEM) spectroscopy.
Harmful Algal Blooms (HABs)
Harmful Algal Blooms (HABs)
This study describes the application of simultaneous absorbance and fluorescence excitation-emission matrix (EEM) analysis for the purpose of identification and classification of freshwater planktonic algal species.
Disinfection Byproducts (DBPs) and Precursors in Drinking Water for EPA Compliance
Disinfection Byproducts (DBPs) and Precursors in Drinking Water for EPA Compliance
This application note describes the use of the Aqualog for monitoring regulated Dissolved Organic Matter (DOM) and disinfection by-product issues for drinking water treatment.
Petroleum and Oil Spill Products
Petroleum and Oil Spill Products
Global drinking water sources remain prone to carcinogenic petroleum product contaminations due to lack of detection capacity at or before treatment plant intake. The Aqualog A-TEEM method provides a reliable optical detection of these compounds at low quantities discriminating from the highly absorbing and fluorescent backgrounds of natural Dissolved Organic Matter (DOM) components.

Request for Information

Do you have any questions or requests? Use this form to contact our specialists.

* These fields are mandatory.

Product accessories

Fast-01
Fast-01

Aqualog A-TEEM Autosampler Accessory

Solid Sample Tray
Solid Sample Tray

Greater Versatility and User Functionality

Related products

Aqualog - A-TEEM Industrial QC/QA Analyzer
Aqualog - A-TEEM Industrial QC/QA Analyzer

A Simple, Fast, “Column Free” Molecular Fingerprinting Technology

Aqualog - Water Treatment Plant Analyzer
Aqualog - Water Treatment Plant Analyzer

Automated Organic Analysis & Early Warning Sentinel

Corporate