HE-960CW

面板安裝型雙通道電導率儀(電導率計)

蒸氣滅菌期間藥物水管理和溫度監測的理想選擇。

從純水到2000μs/cm的水質管理的理想電導率計。水質確定功能專為製藥業設計,符合USP <645>(美國藥房),使其非常適合管理藥水(例如注入水)(WFI)。提供符合各國的藥典(USP,EP)的藥物製造流程的感測器陣容,以及適合樣品特性的感測器。使用面板安裝變送器可以降低安裝成本。

COND

產品分類: Process Water
製造商: HORIBA Advanced Techno Co., Ltd.Finesse Solutions, LLC

Diverse lineup of sensors available

We offer general-purpose sensors suitable for pure water and boiler water control and wastewater treatment monitoring, as well as sensors for pharmaceutical manufacturing processes that comply with the pharmacopoeias of various countries (USP, EP, JP). Materials that can accommodate specialized water requirements are also offered.

Possible to be used in a panel-mounted configuration

This transmitter is easy to install while providing standard functions.

2-channel specification

Allowing measurement at 2 points, and capable of displaying salt removal rate.

Product nameIndustrial 2-channel conductivity meter
ModelHE-960CW
Measurement
method
Electrode type (2-electrode method)
Sensor input2 channels (for concurrent measurement with sensors isolated each other)
Cell constant0.01/cm, 0.1/cm, or 1.0/cm
Temperature
sensor
specifications
Platinum resistance 1000 Ω/0℃
Measuring rangeCell constant (/cm)0.01
(ESD/ESL/ESH-001)
0.1
(ESD/ESL/ESH/FS-01)
1.0
(ESD/ESL/ESH-1)
Conductivity
range
(μS/cm)2.000/20.002.000/20.00/200.0/2000*200.0/2000
(mS/m)0.2000/2.0000.2000/2.000/20.00/200.0*20.00/200.0
TDS
conversion
(mg/L)2.000/20.002.000/20.00/200.0/2000*200.0/2000
*: Applicable for only sanitary sensor (FS-01 series)
Temperature0℃ to 100℃
Desalination rate0.0% to 100.0%
Conductivity
difference
Depends on measurement range of sensor 2 (CH2).
RepeatabilityConductivity displayWithin ±0.5% of the full scale (in equivalent input)
2000 μS/cm and 200.0 mS/m ranges of FS-01: Within ±2% of the full scale
TDS conversion
display
Within ±1.5% of the full scale (in equivalent input)
LinearityConductivity displayWithin ±0.5% of the full scale (in equivalent input)
2000 μS/cm and 200.0 mS/m ranges of FS-01: Within ±2% of the full scale
TDS conversion
display
Within ±1.5% of the full scale (in equivalent input)
Display/output
range
ConductivityMeasurement range
Temperature−30℃ to 160℃
Desalination rate0% to 100%
Conductivity
difference
Measurement range of sensor 2 (CH2)
Transmission
output
Number of outputs: 4
4 mA to 20 mA DC/0 mA to 20 mA DC, input/output isolated type
Maximum load resistance: 900 Ω
Transmission output range: Freely selectable within the measurement range(Negative terminals of each transmission output channel are connected inside and thus have the same electric potential.)
Contact output
  • Number of outputs: 4
  • Alarm contact outputs (R1, R2, and R3)
      Contact type: relay contact, SPST (1a)
      Contact rating: 240 V AC, 3 A and 30 V DC, 3 A (resistance load)
      Contact function: selectable from the upper/lower limit action (ON/OFF control), delay, and hysteresis.
      Output contents: selectable from the selected measurement, USP assessment,anomaly alarm and maintenance.
  • Alarm contact output (R4)
      Contact type: relay contact, SPDT (1c)
      Contact rating: 240 V AC, 3 A and 30 V DC, 3 A (resistance load)
      Contact function: selectable from the upper/lower limit action (ON/OFF control), delay, and hysteresis.
      Output contents: selectable from the selected measurement, USP assessment,anomaly alarm and maintenance.
      (However, R1 and R2, and R3 and R4 share the common contacts respectively.)
  • Contact operation (operation between C and NO for R1 to R4)
      When selected measurement, USP assessment, or maintenance is selected in output contents:
      Contact point becomes “CLOSE” at control operation and “OPEN” at normal state (including power shutdown).
      When anomaly alarm is selected in output contents:
    Contact point becomes “CLOSE” at normal state and “OPEN” at anomaly state (including power shutdown).
      (When between C and NC is used with R4, contact point becomes reverses state with that of between C and NO.)
Communication
output
RS-485 input/output
Calibration
function
Conductivity: Based on the specified compensation coefficient for cell constant (parameter input).
Temperature: Calibrated by comparing with the reference thermometer.
TDS: Conversion using a user-defined coefficient value (0.30 to 1.00).
Transmission
output hold
feature
  • Previous value hold
  • Optional value hold
    Selectable from the above
    (However, only the previous value hold is available in the maintenance mode.)
Self-diagnosis
function
  • Sensor diagnosis
    Short-circuit and disconnection of the temperature sensor
  • Out of the measurement range
  • Converter error
Temperature
compensation
  • Temperature characteristic of NaCl (reference temperature: 5℃ to 95℃)
  • Arbitrary temperature coefficient entry.
    (reference temperature: 5℃ to 95℃: temperature coefficient: ±5%/℃)
    (In the deionized water area, however, the temperature compensation for deionized water is automatically performed in both NaCl and arbitrary temperature coefficient compensation settings.)
  • No temperature compensation
Temperaturecompensated
range
0℃ to 100℃
Ambient
temperature
−5℃ to 55℃
Relative humidity20% to 85% (without dew condensation)
Storage
temperature
−25℃ to 65℃
Power supplyRated voltage 100 V to 240 V AC, 50 Hz/60 Hz, 25 VA (maximum)
StructureIndoor-use panel installation type
Panel case: ABS, Terminal: PBT
Panel: IP65 dust and water proof structure
Protective
structure
Panel: IP65 (IEC60529, JIS C0920)
Rear case: IP20, Terminal:IP00
Class II device (IEC61010-1)
Pollution level 2 (IEC61010-1)
Conforming
standards
CE MarkingEMC Directive: EN61326-1
Low Voltage Directive: EN61010-1
RoHS Directive: EN50581
FCC RuleFCC Part15
External
dimensions
96 (W) mm × 96 (H) mm × 115 (D) mm
Case depth: approx. 105 mm (when panel-mounted)
MassApprox. 550 g
Compatible
sensors
Sensor typeModelCell constant (/cm)Temperature
coefficient of
temperature
sensor (ppm/℃)
Insert typeESD/ESL series0.01, 0.1, 1.03750
ESH series0.01, 0.1, 1.03850
Sanitary insert typeESD-01C-SN1.50.13750
ESH-01C-SN1.50.13850
Sanitary flow-through
type
FS-01C-SL series0.13750
FS-01FC-SL series0.13850

留言諮詢

如您有任何疑問,请在此留下詳細需求或問題,我們將竭誠您服務。

* 這些欄位為必填項目。

Related products

514-22
514-22

1.41 mS/cm Conductivity Standard Solution

514-23
514-23

12.9 mS/cm Conductivity Standard Solution

9371-10D Conductivity Cell
9371-10D Conductivity Cell

Conductivity Cell for Ultra Pure Water Measurement

HD-960LR
HD-960LR

Dissolved Oxygen Concentration Monitor Series for Semiconductor Manufacturing

LAQUA DO210
LAQUA DO210

Handheld Dissolved Oxygen/Temperature Meter

LAQUA DO220
LAQUA DO220

Handheld Dissolved Oxygen/Temperature Meter

LAQUA DS-72
LAQUA DS-72

Benchtop Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUA EC1100
LAQUA EC1100

Benchtop Water Quality Meters

LAQUA EC210
LAQUA EC210

Handheld Conductivity/Resistivity/Salinity/Total Dissolved Solids/Temperature Meter

LAQUA EC220
LAQUA EC220

Handheld Conductivity/Resistivity/Salinity/Total Dissolved Solids/Temperature Meter

LAQUA F-72
LAQUA F-72

Benchtop pH/ORP/Ion/Temperature Meter

LAQUA F-73
LAQUA F-73

Benchtop pH/ORP/Ion/Temperature Meter

LAQUA F-74
LAQUA F-74

Benchtop pH/ORP/Ion/Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUA PC1100
LAQUA PC1100

Benchtop Water Quality Meters

LAQUA PC210
LAQUA PC210

Handheld pH/ORP/Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUA PC220
LAQUA PC220

Handheld pH/ORP/Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUA PD210
LAQUA PD210

Handheld pH/ORP/Dissolved Oxygen/Temperature Meter

LAQUA PD220
LAQUA PD220

Handheld pH/ORP/Dissolved Oxygen/Temperature Meter

HD-960LR
HD-960LR

Dissolved Oxygen Concentration Monitor Series for Semiconductor Manufacturing

HT-110
HT-110

On-line TOC analyzer

LAQUA DO210
LAQUA DO210

Handheld Dissolved Oxygen/Temperature Meter

LAQUA DO220
LAQUA DO220

Handheld Dissolved Oxygen/Temperature Meter

LAQUA DS-72
LAQUA DS-72

Benchtop Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUA EC1100
LAQUA EC1100

Benchtop Water Quality Meters

LAQUA EC210
LAQUA EC210

Handheld Conductivity/Resistivity/Salinity/Total Dissolved Solids/Temperature Meter

LAQUA EC220
LAQUA EC220

Handheld Conductivity/Resistivity/Salinity/Total Dissolved Solids/Temperature Meter

LAQUA F-74
LAQUA F-74

Benchtop pH/ORP/Ion/Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUAtwin EC-11
LAQUAtwin EC-11

Pocket Water Quality Meters

LAQUAtwin EC-22
LAQUAtwin EC-22

Pocket Water Quality Meters

LAQUAtwin EC-33
LAQUAtwin EC-33

Pocket Water Quality Meters

LAQUAtwin Salt-11
LAQUAtwin Salt-11

Pocket Water Quality Meters

LAQUAtwin Salt-22
LAQUAtwin Salt-22

Pocket Water Quality Meters

PM-960, PM-100
PM-960, PM-100

Peracetic acid concentration monitor

Sanitary Conductivity Sensor (Ferrule Clamp type) FES-210L
Sanitary Conductivity Sensor (Ferrule Clamp type) FES-210L

Insertion sensor type for wide-range conductivity meter HE-960HI

TOCADERO ONE
TOCADERO ONE

Automatic Total Organic Carbon Analyzer (On-line TOC analyzer)

Corporate