ENDA-5000 series

Stack Gas Analysis System

Continuous simultaneous and high-precision measurement of NOx, SO2, CO, CO2 and O2

HORIBA has over 100,000 CEM systems installed and 30 years of quality and experience. That is the base on which HORIBA's new ENDA-5000 series of stack-gas analysis systems are built. These systems have a small footprint and use cross-flow modulated non-dispersive infrared (NDIR) and magneto-pneumatic detectors that are inherently drift-free. The ENDA-5000 series are superior continuous analysis systems that perform reliably for difficult exhaust gas measurements, when measurement errors cannot be tolerated. This CEM series features a new intuitive touch panel that makes every operation available with the touch of a single button. The ENDA-5000 series systems are also designed for ease of maintenance. They are ideal for a variety of uses, including emissions monitoring from steam boilers, refuse incinerators, and electric power generation plants to assure pollution standards are being met.

 

Division: Combustion
Manufacturing Company: HORIBA, Ltd.
  • Long-term stability : Cross-flow modulated non-dispersive infrared (NDIR) detection is renowned for long-term stability
     
    1. No need for optical adjustments
      With  NDIR, the sample gas and reference gas are intromitted into a single measurement cell alternately to obtain modulation signal. Therefore there is no need to adjust two different optical paths so that they are balanced.
    2. A stable zero point
      Since ENDA-5000 series output the difference between the measured gas and the reference gas each time measurement occures (once a second), the zero point is extremely stable.
    3. Continuous cleaning keeps the cell clean
      Since cleaning air is fed into the sample cell in between each batch of sample gas, the cell resistes contamination and normally remains clean.This reduces span drift and makes the equipment safe and stable for long periods of time.
       
  • Compact : Body yields wider maintenance area
    ENDA-5000 series can be installed almost anywhere, with ample room on all sides for easy access and much easirer maintenance.
     
  • Easy to use : Features an intuitive touch panel
    The operator can easily switch between the corrected and converted density settings screens or view alert information with touch of a single button.

       
    1. Complies to world environemental regulations by local engineering

      * Please consult HORIBA for further details.


      <Other Features>

    2. Continuous simultaneous measurement of up to 5 components with one system
      HORIBA's innovative optical technology enables ENDA-5000 series measure up to five components which can be arranged any combination.
       
    3. Correction for interference
      The interference correcting sensor uses a unique interference filter to compensate for the influence of interference by other gases.
       
    4. Better alerts and extra alerts
      In addition to the alert functions available in the past, the ENDA-5000 series feature extra alert functions. A continuous checking process can prevent the unit from stopping due to a failure, reducing the risk of failed measurements and assuring consistent operation.
       
    5. Dramatically reduced correction time for SO2
      Corrections of SO2 measurements using wet base methods of the past took a great deal of time (about 15 minutes), but with the ENDA-5000 series' dry base method, correction takes only three minutes.

     

    Related Industries

    Thermal Power Generation

    Waste to Energy Power Generation

    Biomass Power Generation

    Iron and Steel Production

    Oil Refinery

    Petrochemical Industry

    Related Applications

    Monitoring of SO2 for Flue Gas Desulfurization

    Model

    ENDA-5000

    Component

    NOx

    SO2

    CO

    CO2

    O2*1

    Measurement methods

    NDIR

    NDIR

    NDIR

    NDIR

    Magneto-pneumatic detection

    Range*2

    Standard

    200~5000 ppm

    200~5000 ppm

    200~5000 ppm

    5~25 vol%

    10~25 vol%

     

    Option

    100 ppm~

    50 ppm~

    100 ppm~

    -

    -

    Range Ratio

    Within a factor of 10

    Within a factor of 10

    Within a factor of 10

    Within a factor of 5

    Within a factor of 2.5

    Repeatability

    Within 0.5% of full scale/week (with optional range, or during O2 measurement, ±1.0% of full scale/week)

    Linearity (indicator error)

    ±1.0% of full scale

    Zero drift

    ±1.0% of full scale/week (assuming surrounding temperature is maintained within 5 °C)
    (with optional range, or O2 measurement, ±2.0% of full scale/week)

    Span drift

    ±2.0% of full scale/week (assuming surrounding temperature is maintained within 5°)

    Response time*3

    Within 60 seconds (Td + T90 from equipment intake area) (sample flow 0.6 L/min.) (within 240 seconds for SO2 only)

    Overall interference from co-existing gases

    ±2.0% of full scale (within standard range, with standard gas formation)

    Display

    Touch panel LCD (backlight) (four usable lines)

    Environment
    Condition

    Temperature

    -5 to 40 °C (away from direct sunlight and radiation heat )*4

    Humidity

    85% or less (no condensation)

    Vibration

    100 Hz, 0.3 m/s2or less

    Dust

    Standard environment or better

    Measuring Gas Condition

    Temperature

    250 °C or lower

    Dust

    0.1 g/Nm3 or less

    Standard gas composition*5

    NO: 500 ppm or less; NO2: 15 ppm or less; SO2: 1000 ppm or less; SO3: 50 ppm or less;
    CO: 200 ppm or less; CO2: 15% volume or less; H2O: 20% volume or less

    Sampling method

    Dry sampling using an electric cooler

    Sample gas flow

    2.5 L/min~3.0 L/min

    Sample inlet tube

    Teflon tubing (Ø8/Ø6 mm)

    Sample gas pressure

    ±4.9 kPa (three points selected)
    (with no sample gas back pressure)

    (1) -1.96 to 4.9 kPa
    (2) ±3.43 kPa
    (3) -4.9 to 1.96 kPa

     

    Pressure control

    Pressure control uses a regulator and pump; Reduced pressure sampling; Control pressure: -4.9 kPa

    Output

    DC 4 to 20 mA (absolute output) (DC 0 to 16 mA/DC 0 to 1 V/DC 1 to 5V optional) Max. 12 output systems

    External output

    Analysis alerts, analysis warnings, range display, corrections, conservation, purging (option)
    Contact capacity: DC 30 V 1 A, AC 250 V 1 A resistance load

    Correction method

    Dry correction, automatic correction (correction cycle: 7 days standard, can be adjusted to between 1 and 99 days), manual correction

    Calibration gas

    Zero gas

    With measurement method authorization: N2, When there is no measurement method authorization: N2 or ambient air

    O2 carrier gas

    Ambient air

    Span gas

    Gas cylinder for each component measured (when there is no measurement method authorization: O2 or ambient air can be used)

    Probe collection point filter

    Flange: JIS 10K, 40 AFF; Sample probe tube length: 1000 mm; Material: SUS-316 stainless steel;
    Filter element: SUS-304 stainless steel and 2um-pleated quartz wool; Electric heater: 100 VA, with water droplet proof case

    Power supply

    AC 100 V ±15 V(85 V~115 V)

    Power frequency

    50/60 Hz (switchable)

    Power consumption

    About 800 VA (heated piping 30m: +1100 VA; heater in tray: +300 VA)

    Exterior dimensions/Mass

    600 (W) x 1770 (H) x 300 (D) mm (high pressure gas cylinders, 3.4 L cylinders, maximum of 3 cylinders); About 180 kg (not including cylinders)
    600 (W) x 1770 (H) x 300 (D) mm (high pressure gas cylinders, 3.4 L cylinders, maximum of 3 cylinders); About 200 kg (not including cylinders)

    Materials in contract with sample gas

    SUS-316 stainless steel, SUS-304 stainless steel, Teflon, polypropylene, polyethylene,
    flourorubber, PVC, PVDF, and glass

    Enclosure

    Independent outdoor installation
    Plate thickness: Main unit, doors, top plate, steel plate: 2.3 mm; Channel base: 3.2 mm; Doors: front opening; Interface: right front

    Color/Finish

    Semi-gloss Munsell 5Y7/1 on all inner and outer surfaces

    *1: No carrier gas cylinder is required.

    *2: Up to two ranges are supported for each component.

    *3: Response time may vary depending on the sampling system composition.

    *4: Support is available for -15 to 40 °C (cold-climate version) and 5 to 50 °C.

    *5: An NH3 scrubber is available as an option for cases where a combined gas includes NH3. SO2 measurement corrected for CH4 interference is available for cases where there is CH4 in the sample gas for SO2 measurement. CO measurement corrected for N2O interference is available for cases where there is N2O in the sample gas for CO measurement.

    Solid Waste Combustors and Incinerators in Solid Waste Management and Remediation Services
    Solid Waste Combustors and Incinerators in Solid Waste Management and Remediation Services
    Nitrous Oxide Monitoring for Greenhouse Gas Reduction
    Nitrous Oxide Monitoring for Greenhouse Gas Reduction
    Monitoring of SO2 for Flue Gas Desulfurization
    Monitoring of SO2 for Flue Gas Desulfurization

    Request for Information

    Do you have any questions or requests? Use this form to contact our specialists. * These fields are mandatory.

    Related products

    AQMS
    AQMS

    Ambient Air Quality Monitoring System

    CEMS
    CEMS

    Continuous Emission Monitoring System

    GI-700 series
    GI-700 series

    Stack Gas Analyzer

    PG-300 series
    PG-300 series

    Portable Gas Analyzer

    TX-100
    TX-100

    Tunable Laser Gas Analyzer

    VA-5000 / VA-5000WM Series
    VA-5000 / VA-5000WM Series

    Multi-Component Gas Analyzer

    51 series
    51 series

    Explosion-proof Gas Analyzer

    AP-370 series
    AP-370 series

    Air Pollution Monitor

    APCA-370
    APCA-370

    Ambient Carbon Dioxide Monitor

    APHA-370
    APHA-370

    THC Analysator

    APMA-370
    APMA-370

    Ambient Carbon Monoxide Monitor

    APNA-370
    APNA-370

    Ambient NOx Monitor

    APNA-370/CU-2
    APNA-370/CU-2

    Ambient Ammonia Monitor

    APOA-370
    APOA-370

    Ambient Ozone Monitor

    APSA-370
    APSA-370

    Ambient Sulfur Dioxide Monitor

    APSA-370/CU-1
    APSA-370/CU-1

    Ambient Hydrogen Sulfide Monitor

    AQMS
    AQMS

    Ambient Air Quality Monitoring System

    CEMS
    CEMS

    Continuous Emission Monitoring System

    FTX-ONE-CL
    FTX-ONE-CL

    FTIR Exhaust Gas Analyzer Dilute Measurement Type

    FTX-ONE-CS/RS
    FTX-ONE-CS/RS

    FTIR Exhaust Gas Analyzer Direct Measurement Type

    GA-370
    GA-370

    Trace Gas Monitor

    GI-700 series
    GI-700 series

    Stack Gas Analyzer

    IR-300
    IR-300

    Vapor Concentration Monitor

    IR-400
    IR-400

    High-grade type Gas Monitor for Chamber Cleaning End Point Monitoring

    MEXA-1170HCLD
    MEXA-1170HCLD

    Heated Type NOx Analyzer

    MEXA-1170HFID
    MEXA-1170HFID

    Heated Type THC Analyzer

    MEXA-1170SX
    MEXA-1170SX

    Motor Exhaust Gas Sulfur Analyzer

    MEXA-1300R
    MEXA-1300R

    Motor Exhaust Gas Analyzer

    MEXA-584L
    MEXA-584L

    Automotive Emission Analyzer

    MEXA-ONE
    MEXA-ONE

    Motor Exhaust Gas Analyzer

    MEXA-ONE-FT
    MEXA-ONE-FT

    FTIR Motor Exhaust Gas Analyzer

    MEXA-ONE-QL-NX
    MEXA-ONE-QL-NX

    Laser Spectroscopic Motor Exhaust Gas Analyzer

    OBS-ONE GS Unit
    OBS-ONE GS Unit

    On-board Emissions Measurement System

    OBS-ONE IRLAM Unit
    OBS-ONE IRLAM Unit

    On-board NH3/N2O Measurement System for real-world driving

    PG-300 series
    PG-300 series

    Portable Gas Analyzer

    Process
    Process

    Process Analyzer System

    TX-100
    TX-100

    Tunable Laser Gas Analyzer

    VA-5000 / VA-5000WM Series
    VA-5000 / VA-5000WM Series

    Multi-Component Gas Analyzer

    51 series
    51 series

    Explosion-proof Gas Analyzer

    AP-370 series
    AP-370 series

    Air Pollution Monitor

    APCA-370
    APCA-370

    Ambient Carbon Dioxide Monitor

    APMA-370
    APMA-370

    Ambient Carbon Monoxide Monitor

    EMGA-920
    EMGA-920

    Oxygen/Nitrogen Analyzer

    EMGA-921
    EMGA-921

    Hydrogen Analyzer

    EMGA-930
    EMGA-930

    Oxygen/Nitrogen/Hydrogen Analyzer

    EMGA-Expert
    EMGA-Expert

    Oxygen/Nitrogen/Hydrogen Analyzer
    (Flagship High-Accuracy Model)

    EMGA-Pro
    EMGA-Pro

    Oxygen/Nitrogen Analyzer (Entry Model)

    EMIA-Expert
    EMIA-Expert

    Carbon/Sulfur Analyzer

    EMIA-Pro
    EMIA-Pro

    Carbon/Sulfur Analyzer

    EMIA-Step
    EMIA-Step

    Carbon/Sulfur Analyzer

    GA-370
    GA-370

    Trace Gas Monitor

    GI-700 series
    GI-700 series

    Stack Gas Analyzer

    IR-300
    IR-300

    Vapor Concentration Monitor

    IR-400
    IR-400

    High-grade type Gas Monitor for Chamber Cleaning End Point Monitoring

    LO-300
    LO-300

    Laser scanning Oil Film Detector

    MEXA-1300R
    MEXA-1300R

    Motor Exhaust Gas Analyzer

    MEXA-584L
    MEXA-584L

    Automotive Emission Analyzer

    MEXA-ONE
    MEXA-ONE

    Motor Exhaust Gas Analyzer

    OBS-ONE GS Unit
    OBS-ONE GS Unit

    On-board Emissions Measurement System

    OBS-ONE IRLAM Unit
    OBS-ONE IRLAM Unit

    On-board NH3/N2O Measurement System for real-world driving

    OCMA-500
    OCMA-500

    Oil Content Analyzer

    OCMA-550
    OCMA-550

    Oil Content Analyzer

    PG-300 series
    PG-300 series

    Portable Gas Analyzer

    TX-100
    TX-100

    Tunable Laser Gas Analyzer

    VA-5000 / VA-5000WM Series
    VA-5000 / VA-5000WM Series

    Multi-Component Gas Analyzer

    Corporate