CS-100F1 Series

Fiber Optic Type Chemical Solution Concentration Monitor

An inline, real-time optical fiber-based chemical concentration monitor that enables measurements of chemicals used in semiconductor manufacturing processes such as cleaning and etching.

Inline real-time measurements can be obtained.  A single concentration monitor is capable of simultaneously measuring up to four types (chemicals or ranges), making it suitable for measurements in single wafer cleaning.

Chemical Concentration

AC(100-240V)Transmission OutputContact OutputRS-232C

Segment: Semiconductor
Produktionsfirma: HORIBA Advanced Techno Co., Ltd.

Multi-monitoring

Measurements of up to four different substances (chemicals or ranges) are possible with a single concentration monitor.

Short measurement cycles and fast response time

Supports concentration management for 300mm processes with a measurement cycle of approximately 3 seconds. Precise concentration management for both multi-bath and single-bath/sheet-type cleaning equipment are supported.

One of two types can be chosen

The option is available to choose between two types: the inline cell type, which is directly integrated into the main piping and prioritizes real-time concentration tracking, or the cell unit type, which emphasizes stability and allows for feedback control using monitor outputs.

ModelCS-151F1CS-152F1CS-150F1
Target of
measurement
SC-1
(ammonia/hydrogen peroxide
aqueous solution)
SC-2
(hydrochloric acid/hydrogen
peroxide aqueous solution)
SPM
(sulfuric acid/hydrogen
peroxide aqueous solution)
Multi-monitoring with one unit of up to 4 types of chemical solutions or ranges possible.
Measurement principleAbsorption spectrometry
Concentration computation
principle
Temperature-compensated multivariate analysis
Measurement range
(mass %)
NH3: 0.00% to 1.00%
H2O2: 0.00% to 5.00%
H2O: 94.0% to 100.0%
HCI: 0.00% to 2.00%
H2O2: 0.00% to 2.00%
H2O: 96.0% to 100.0%
H2SO4: 70.0% to 96.0%
H2O2: 0.00% to 10.00%
H2O: 4.0% to 30.0%
Repeatability (mass %)
(within ±1% room temperature)
NH3: ±0.15%
H2O2: ±0.30%
H2O: ±1.5%
HCI: ±0.15%
H2O2: ±0.15 %
H2O: ±1.5%
H2SO4: ±0.50%
H2O2: ±0.50%
H2O: ±1.5%
・Repeatability for the list above is for the cell unit type.Please contact us for the repeatability of the in-line cell type.
・Differences in the above list may occur depending on measurement range.(Please see our website for details.)
Sample solution temperature20 to 80: (when using Inline cell) 20 to 30: (when using cell unit)
Measurement cycleApprox. 3 seconds
Content of
LCD and input
• 1st component: measured concentration value (%)   •Error code
• 2nd component: measured concentration value (%)  •Parallel concentration alarm output invalid status
• 3rd component: measured concentration value (%)  •Serial/parallel status
• 1st and 2nd components: concentration alarm status •Background compensation data
RS-232C serial input• Serial/parallel status switching            •Parallel concentration alarm output status
• Measurement data transfer request         (valid/invalid)
• 1st and 2nd component concentration alarm setting  •Target measurement solution switching
Parallel input12 to 30 V DC (photocoupler insulated)        • Parallel concentration alarm output
                          • Target measurement solution switching
                          • Background compensation
Parallel outputOpen collector output (photocoupler insulated)     • 1st component concentration alarm, 4 types
Max. current when on:                 • 2nd component concentration alarm, 4 types
  DC 5 mA (no internal protection resistor)        • Device error
Max. impressed voltage when off: 30 V DC       • Measuring
                           • Target measurement solution type
                           • Background compensation status
Solution temperature inputTerminal block connection (M3 terminal screws)
• Platinum resistance temperature sensor: Pt100 (Pt100 sensor should be prepared by customers)
Analog output• 1st component concentration alarm, 4 types: 4 to 20 mA
• 2nd component concentration alarm, 4 types: 4 to 20 mA
✽We also support other measurement ranges. Please specify when ordering.
Fiber optic cableDedicated CS-100F1 Series fiber optic cable (25 ±15: installation temperature)
Sample cellWe can supply dedicated sample cells (inline cell or cell unit) for various kinds of chemical solutions.
Power supply100 V to 230 V AC (single phase) ±10%, 50/60 Hz, approx. 100 VA
Dimensions205 (W) x 329 (D) x 269 (H) mm 8.1 (W) x 13.0 (D) x 10.6 (H) in (excluding protruding part)
WeightApprox. 11 kg

Note: Please consult us regarding concentration monitors for chemical solutions other than those given above.

Schematics

Concentration monitor

Inline cell                                                                                     Cell unit

              

Informationsanfrage

Sie haben Fragen oder Wünsche? Nutzen Sie dieses Formular, um mit unseren Spezialisten in Kontakt zu treten.

* Diese Felder sind Pflichtfelder.

Related products

CombiScope
CombiScope

AFM and inverted light microscopy

CS-100 Series
CS-100 Series

Stand-alone Type Chemical Concentration Monitor

CS-600F
CS-600F

Fiber Optic Type Chemical Concentration Monitor

CS-620F
CS-620F

Optical Fiber Type Hot Phosphoric Acid Concentration Monitor

CS-700
CS-700

High Precision, High Stability Chemical Concentration Monitor

CS-900
CS-900

Non-Contact Chemical Concentration Monitor

EG-100
EG-100

Washwater Monitoring System

HD-960L
HD-960L

HF (Hydrofluoric Acid)  DO (Dissolved Oxygen) Monitor / Pure Water DO (Dissolved Oxygen) Monitor

HD-960LR
HD-960LR

Dissolved Oxygen Concentration Monitor Series for Semiconductor Manufacturing

HE-480C-GC
HE-480C-GC

Carbon Sensor Conductivity Meter (Low concentration type)

HE-960CA
HE-960CA

Citric Acid Monitor

HE-960H-KOH
HE-960H-KOH

KOH Monitor

HE-960H-TM
HE-960H-TM

Wide range TMAH Concentration Monitor

HE-960H-TM-S
HE-960H-TM-S

High Precision TMAH Concentration Monitor

HE-960HC
HE-960HC

Carbon Sensor Conductivity Meter (High concentration type)

HE-960LC
HE-960LC

Carbon Sensor Conductivity Meter

HE-960LF / FS-09F-1/2
HE-960LF / FS-09F-1/2

Flat Carbon Sensor Conductivity Meter

HE-960R-GC
HE-960R-GC

Carbon Sensor Resistivity Meter

HE-960RW-GC
HE-960RW-GC

2-Channel Resistivity Meter

HF-700A
HF-700A

Low Concentration Monitor- Sulfuric Acid/Hydrogen Peroxide

HF-960EM
HF-960EM

In-line Sensor & Auto Range Switching Concentration Monitor

HF-960H
HF-960H

HF / HCl Concentration Monitor

HF-960M
HF-960M

Low Concentration Type HF/HCl/NH3 Concentration Monitor

HT-110
HT-110

On-line TOC analyzer

HZ-960
HZ-960

Dissolved Ozone Monitor

HZ-960HPO-M
HZ-960HPO-M

H2O2 Monitor

ICP Neo
ICP Neo

ICP Software

OmegaScope
OmegaScope

The AFM optical platform

OPSA-150
OPSA-150

Organic pollutant monitor

SLIA-300
SLIA-300

Highly sensitive silica monitor for ultra-pure water management in semiconductor/FPD processes

SLIA-5000
SLIA-5000

Silica analyzer

TPNA-500
TPNA-500

Automatic total nitrogen/phosphorus monitor

TRIOS
TRIOS

Versatile AFM Optical Coupling

Ultima Expert LT
Ultima Expert LT

Affordable high performance ICP-OES

UP-100
UP-100

Micro Volume pH Monitor

CS-100 Series
CS-100 Series

Stand-alone Type Chemical Concentration Monitor

CS-600F
CS-600F

Fiber Optic Type Chemical Concentration Monitor

CS-620F
CS-620F

Optical Fiber Type Hot Phosphoric Acid Concentration Monitor

CS-700
CS-700

High Precision, High Stability Chemical Concentration Monitor

CS-900
CS-900

Non-Contact Chemical Concentration Monitor

EG-100
EG-100

Washwater Monitoring System

HF-960M
HF-960M

Low Concentration Type HF/HCl/NH3 Concentration Monitor

HU-200SS
HU-200SS

Field-installation type MLSS meter

HU-200TB-H
HU-200TB-H

Field-installation type turbidity meter

HU-200TB-IM
HU-200TB-IM

Field-installation type turbidity/SS meter

HU-200TB-W
HU-200TB-W

Field-installation type turbidity meter

HZ-960
HZ-960

Dissolved Ozone Monitor

HZ-960HPO-M
HZ-960HPO-M

H2O2 Monitor

OPSA-150
OPSA-150

Organic pollutant monitor

TPNA-500
TPNA-500

Automatic total nitrogen/phosphorus monitor

U-50
U-50

Multi-parameter water quality checker