CS-620F

Optical Fiber Type Hot Phosphoric Acid Concentration Monitor

A phosphoric acid concentration monitor that can perform real-time measurements of high-temperature phosphoric acid without the need for cooling.

Ideal for managing the concentration of phosphoric acid, used primarily in the etching process of the 3D NAND flash memory SiN layer*1, part of the manufacturing process for semiconductors.
*1 SiN layer: A thin film composed of silicon and nitrogen compounds formed on silicon wafers and similar substrates.

Chemical Concentration

AC(100-240V)Transmission OutputContact OutputRS-485High TemperatureNon-contact

Segment: Semiconductor
Produktionsfirma: HORIBA Advanced Techno Co., Ltd.

High concentration and high-temperature compatibility

Capable of directly measuring high-concentration (up to 92%) and high-temperature phosphoric acid (140-170°C) in a circulation line without the need for cooling mechanisms or cooling time.

Low contamination risk

Using PFA at the sample connection point, contamination risk is reduced.

Acceleration of feedback control

Real-time measurements with data updates every 3 seconds have been implemented, achieving faster concentration feedback control.

Reduction in equipment downtime

The adoption of a semi-annual background adjustment cycle has contributed to the reduction of equipment downtime.

Product nameCHEMICAL SOLUTION MONITOR
ModelCS-620F
Measurement principleAbsorption spectroscopic method
Calculation principleTemperature compensation type multivariate analysis
SampleH3PO4/H2O

Measurable range
Repeatability

 ComponentMeasurable range
(mass%)
Repeatability
(mass%)
Analog output
range(mass%)
1st solutionH3PO485.00-92.00+/-0.1085.00-100.00
H2O8.0-15.0+/-0.30.0-15.0
・ Repeatability is defined by maximum error from average (1 hour).
・ In the case of low temperature measurement (140°C) and high temperature measurement (170°C) with the same chemical,
there is possibility of discrepancy (Maximum +/- 0.30%).
Conditions
of Measurement
1) Measurement interval: Approx. 3 sec. (minimum)
2) Moving average: 16 times
Connection fitting size1 inch or 3/4 inch
Sample conditionSample temperature: 140 to 170°C
Atmospheric temperature, Chemical temperature fluctuation: within +/- 1°C (period of time : 1 hour)
Input pressure: 0.2 MPa or less
Pressure fluctuation: 0.02 MPa or less
Flow rate: 1 to 30 L/min
Air(for operation and purge)Connection port: 4 mm O.D. quick joint
Pressure: 0.2 MPa ± 0.02 MPa
Power source100 to 230 V AC (Single-Phase), 50/60 Hz
Power consumptionApprox.85 VA (Transient electric current at the time of the start is excluded)
CommunicationParallel I/O, RS-232C, Analog output
Dimension(Monitor) 200 (W) × 308 (D) × 78 (H) mm
(Lamp unit) 200 (W) × 262 (D) × 100 (H) mm
(Sample cell) 240 (W) × 209 (D) × 205 (H) mm
Weight(Monitor) Approx.3.6 kg
(Lamp unit) Approx.2.8 kg
(Sample cell) Approx.3.0 kg
Ambient temperature(Monitor, Lamp unit) 20 to 30°C
(Optical fiber, Sample cell) 20 to 100°C
* Sudden temperature change should be avoided, within +/- 1°C/1hour
Ambient humidity(Monitor, Lamp unit) 40 to 70% (Should be no dew condensation)
Slanting angle of installation(Monitor, Lamp unit) Within +/-1 degree
(Sample cell) Please install so that air bubbles do not stay up.
Optical fiberLength: 5 m, Bend radius: R150 mm

 

Informationsanfrage

Sie haben Fragen oder Wünsche? Nutzen Sie dieses Formular, um mit unseren Spezialisten in Kontakt zu treten.

* Diese Felder sind Pflichtfelder.

Related products

CS-100 Series
CS-100 Series

Stand-alone Type Chemical Concentration Monitor

CS-100F1 Series
CS-100F1 Series

Fiber Optic Type Chemical Solution Concentration Monitor

CS-600F
CS-600F

Fiber Optic Type Chemical Concentration Monitor

CS-700
CS-700

High Precision, High Stability Chemical Concentration Monitor

CS-900
CS-900

Non-Contact Chemical Concentration Monitor

EG-100
EG-100

Washwater Monitoring System

HC-200F
HC-200F

Field-installation Type Fluoride Ion Concentration Meter

HC-200NH
HC-200NH

Field-installation type ammonia nitrogen meter

HC-300F
HC-300F

Field-installation Type Fluoride Ion Concentration Meter

HD-200
HD-200

Field-installation type dissolved oxygen meter (DO meter)

HD-200FL
HD-200FL

Field-installation type optical dissolved oxygen meter (DO meter)

HD-300
HD-300

Field-installation type dissolved oxygen meter (DO meter)

HD-480
HD-480

Panel-mount type dissolved oxygen meter (DO meter)

HD-960L
HD-960L

HF (Hydrofluoric Acid)  DO (Dissolved Oxygen) Monitor / Pure Water DO (Dissolved Oxygen) Monitor

HD-960LR
HD-960LR

Dissolved Oxygen Concentration Monitor Series for Semiconductor Manufacturing

HE-200C
HE-200C

Field-installation type electric conductivity meter (conductivity meter)

HE-200H
HE-200H

Field-installation type electric conductivity meter

HE-200R
HE-200R

Field-installation type electric resistivity meter (resistivity meter)

HE-300C
HE-300C

Field-installation type electrical conductivity meter (conductivity meter)

HE-300R
HE-300R

Field-installation type electric resistivity meter (resistivity meter)

HE-480C
HE-480C

Panel-mount type conductivity meter (conductivity meter)

HE-480C-GC
HE-480C-GC

Carbon Sensor Conductivity Meter (Low concentration type)

HE-480H
HE-480H

Panel-mount type conductivity meter (conductivity meter)

HE-480R
HE-480R

Panel-mount type resistivity meter (resistivity meter)

HE-480R(W)
HE-480R(W)

Resistivity Meter for Semiconductor Cleaning Processes

HE-960CA
HE-960CA

Citric Acid Monitor

HE-960CW
HE-960CW

Panel-mount type 2-channel conductivity meter (conductivity meter)

HE-960H-KOH
HE-960H-KOH

KOH Monitor

HE-960H-TM
HE-960H-TM

Wide range TMAH Concentration Monitor

HE-960H-TM-S
HE-960H-TM-S

High Precision TMAH Concentration Monitor

HE-960HC
HE-960HC

Carbon Sensor Conductivity Meter (High concentration type)

HE-960HI
HE-960HI

Panel-mount type conductivity meter

HE-960LC
HE-960LC

Carbon Sensor Conductivity Meter

HE-960LF / FS-09F-1/2
HE-960LF / FS-09F-1/2

Flat Carbon Sensor Conductivity Meter

CS-100 Series
CS-100 Series

Stand-alone Type Chemical Concentration Monitor

CS-100F1 Series
CS-100F1 Series

Fiber Optic Type Chemical Solution Concentration Monitor

CS-600F
CS-600F

Fiber Optic Type Chemical Concentration Monitor

CS-700
CS-700

High Precision, High Stability Chemical Concentration Monitor

CS-900
CS-900

Non-Contact Chemical Concentration Monitor

EG-100
EG-100

Washwater Monitoring System

HF-960M
HF-960M

Low Concentration Type HF/HCl/NH3 Concentration Monitor

HU-200SS
HU-200SS

Field-installation type MLSS meter

HU-200TB-H
HU-200TB-H

Field-installation type turbidity meter

HU-200TB-IM
HU-200TB-IM

Field-installation type turbidity/SS meter

HU-200TB-W
HU-200TB-W

Field-installation type turbidity meter

HZ-960
HZ-960

Dissolved Ozone Monitor

HZ-960HPO-M
HZ-960HPO-M

H2O2 Monitor

OPSA-150
OPSA-150

Organic pollutant monitor

TPNA-500
TPNA-500

Automatic total nitrogen/phosphorus monitor

U-50
U-50

Multi-parameter water quality checker