CS-620F

Optical Fiber Type Hot Phosphoric Acid Concentration Monitor

Keywords: 3D NAND, SiN(Silicon nitride), Etching, Hot phos(Hot phosphoric acid),

In 3D NAND manufacturing process, dozens of layers of SiO2 and SiN are deposited, and the SiN layer is selectively removed using hot phos.
In this process, the desired etching rate can be achieved by controlling the concentration and temperature of the chemical solution.
Previous products have difficulty to measure high temperature chemicals, but the CS-620F is able to measure at high temperatures  up to 170 C degrees. 
Continuous Measurements are made using absorption spectroscopy, which requires less maintenance and fewer consumables versus other methods. 

Segment: Semiconductor
Produktionsfirma: HORIBA Advanced Techno Co., Ltd.

Key features

High concentration phosphoric acid up to 92% can be measured

No cooling mechanism and cooling time is needed.
Direct measurement is possible without cooling high-temperature phosphoric acid (140 to 170°C) in the circulation line.

PFA is used in the sample wetted area to reduce contamination risk.

Contributes to significant reduction in equipment downtime by adopting semi-annual background correction cycles.

Contributes to faster concentration feedback control by updating measured data every 3 seconds

Stability

▶ Measurement results
The sample (actual solution) measured for 1 hour shows exellent stability.

▶ Measurement conditions
Measurement Cycle: every 3 seconds   Measurement time: 1 hour   Moving average: 16 times 
Sample concentration (Initial Sample Concentration)   H3PO4: 92.2%   H2O: 7.8%   Sample temperature: 141°c

Recommend Products


CS-700
High Precision, High Stability
Chemical Concentration Monitor

CS-600F
Fiber Optic Type Chemical
Concentration Monitor
Dissolved Oxygen Monitor in Low Concentration - HF HD-960L
HF HD-960L
Dissolved Oxygen Monitor
in Low Concentration
Product nameCHEMICAL SOLUTION MONITOR
ModelCS-620F
Measurement principleAbsorption spectroscopic method
Calculation principleTemperature compensation type multivariate analysis
SampleH3PO4/H2O

Measurable range
Repeatability

 ComponentMeasurable range
(mass%)
Repeatability
(mass%)
Analog output
range(mass%)
1st solutionH3PO485.00-92.00+/-0.1085.00-100.00
H2O8.0-15.0+/-0.30.0-15.0
・ Repeatability is defined by maximum error from average (1 hour).
・ In the case of low temperature measurement (140°C) and high temperature measurement (170°C) with the same chemical,
there is possibility of discrepancy (Maximum +/- 0.30%).
Conditions
of Measurement
1) Measurement interval: Approx. 3 sec. (minimum)
2) Moving average: 16 times
Connection fitting size1 inch or 3/4 inch
Sample conditionSample temperature: 140 to 170°C
Atmospheric temperature, Chemical temperature fluctuation: within +/- 1°C (period of time : 1 hour)
Input pressure: 0.2 MPa or less
Pressure fluctuation: 0.02 MPa or less
Flow rate: 1 to 30 L/min
Air(for operation and purge)Connection port: 4 mm O.D. quick joint
Pressure: 0.2 MPa ± 0.02 MPa
Power source100 to 230 V AC (Single-Phase), 50/60 Hz
Power consumptionApprox.85 VA (Transient electric current at the time of the start is excluded)
CommunicationParallel I/O, RS-232C, Analog output
Dimension(Monitor) 200 (W) × 308 (D) × 78 (H) mm
(Lamp unit) 200 (W) × 262 (D) × 100 (H) mm
(Sample cell) 240 (W) × 209 (D) × 205 (H) mm
Weight(Monitor) Approx.3.6 kg
(Lamp unit) Approx.2.8 kg
(Sample cell) Approx.3.0 kg
Ambient temperature(Monitor, Lamp unit) 20 to 30°C
(Optical fiber, Sample cell) 20 to 100°C
* Sudden temperature change should be avoided, within +/- 1°C/1hour
Ambient humidity(Monitor, Lamp unit) 40 to 70% (Should be no dew condensation)
Slanting angle of installation(Monitor, Lamp unit) Within +/-1 degree
(Sample cell) Please install so that air bubbles do not stay up.
Optical fiberLength: 5 m, Bend radius: R150 mm

 

Request for Information

Do you have any questions or requests? Use this form to contact our specialists. * These fields are mandatory.

Related products

CS-100 Series
More CS-100 Series

Stand-alone Type Chemical Concentration Monitor

CS-100F1 Series
More CS-100F1 Series

Fiber Optic Type Chemical Solution Concentration Monitor

CS-600F
More CS-600F

Fiber Optic Type Chemical Concentration Monitor

CS-700
More CS-700

High Precision, High Stability Chemical Concentration Monitor

CS-900
More CS-900

Non-Contact Chemical Concentration Monitor

FS-3000
More FS-3000

Thermal Flow Splitter

HD-960L
More HD-960L

Dissolved Oxygen Monitor in Low Concentration

HE-200C
More HE-200C

Field-installation Type Electric Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HE-300C
More HE-300C

Field-installation Type Electric Conductivity Meter (Two-Wire Transmission, For Low-concentration)

HE-300R
More HE-300R

Field-installation Type Electric Resistivity Meter (Two-Wire Transmission)

HE-480C
More HE-480C

Panel-mount Type Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HE-480C-GC
More HE-480C-GC

Carbon Sensor Conductivity Meter (Low concentration type)

HE-480R
More HE-480R

Panel-mount Type Resistivity Meter(Four-Wire Transmission)

HE-480R(W)
More HE-480R(W)

Industrial resistivity meter

HE-960CA
More HE-960CA

Citric Acid Monitor

HE-960H-TM
More HE-960H-TM

Wide range TMAH Concentration Monitor

HE-960H-TM-S
More HE-960H-TM-S

High Precision TMAH Concentration Monitor

HE-960HC
More HE-960HC

Carbon Sensor Conductivity Meter (High concentration type)

HE-960LC
More HE-960LC

Carbon Sensor Conductivity Meter

HE-960LF / FS-09F-1/2
More HE-960LF / FS-09F-1/2

Flat Carbon Sensor Conductivity meter

HE-960R-GC(W)
More HE-960R-GC(W)

Carbon Sensor Resistivity Meter

HE-960RW-GC(W)
More HE-960RW-GC(W)

2-Channel Resistivity Meter

HE-960TM
More HE-960TM

TMAH Conductivity Meter. Perfect for Controlling TMAH Developer Concentrations

HF-960EM
More HF-960EM

In-line Sensor & Auto Range Switching Concentration Monitor

HF-960H
More HF-960H

HF / HCl Concentration Monitor

HF-960M
More HF-960M

Low Concentration Type HF/HCl/NH3 Concentration Monitor

HF-SP-CU
More HF-SP-CU

2-channel High Precision HF Concentration Monitor

HP-480(W)
More HP-480(W)

Industrial pH meter

HZ-960
More HZ-960

Dissolved Ozone Monitor

SEC-Z700S Series
More SEC-Z700S Series

New concept Pressure Insensitive Mass Flow Controller

SLIA-300
More SLIA-300

Highly Sensitive Silica Monitor

UP-100
More UP-100

Micro Volume pH Monitor

CS-100 Series
More CS-100 Series

Stand-alone Type Chemical Concentration Monitor

CS-100F1 Series
More CS-100F1 Series

Fiber Optic Type Chemical Solution Concentration Monitor

CS-600F
More CS-600F

Fiber Optic Type Chemical Concentration Monitor

CS-700
More CS-700

High Precision, High Stability Chemical Concentration Monitor

CS-900
More CS-900

Non-Contact Chemical Concentration Monitor

EG-100
More EG-100

Washwater Monitoring System

HC-200F
More HC-200F

Field-installation Type Simplified Fluoride Ion Concentration Meter(Four-Wire Transmission)

HC-200NH
More HC-200NH

Field-installation Type Ammonia Nitrogen Meter(Four-Wire Transmission)

HC-300F
More HC-300F

Field-installation Type Simplified Fluoride Ion Concentration Meter(Two-Wire Transmission)

HD-200
More HD-200

Field-installation Type Dissolved Oxygen Meter (Four-Wire Transmission, Membrane Type)

HD-200FL
More HD-200FL

Field-installation Type Dissolved Oxygen Meter (Four-Wire Transmission, Optical Type)

HD-300
More HD-300

Field-installation Type Dissolved Oxygen Meter(Two-Wire Transmission, Membrane Type)

HD-480
More HD-480

Panel-mount Type Dissolved Oxygen Meter (Four-Wire Transmission, Membrane Type)

HD-960L
More HD-960L

Dissolved Oxygen Monitor in Low Concentration

HE-200C
More HE-200C

Field-installation Type Electric Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HE-200H
More HE-200H

Field-installation Type Electric Conductivity Meter (Four-Wire Transmission, For High-concentration)

HE-200R
More HE-200R

Field-installation Type Electric Resistivity Meter (Four-Wire Transmission)

HE-300C
More HE-300C

Field-installation Type Electric Conductivity Meter (Two-Wire Transmission, For Low-concentration)

HE-300R
More HE-300R

Field-installation Type Electric Resistivity Meter (Two-Wire Transmission)

HE-480C
More HE-480C

Panel-mount Type Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HE-480C-GC
More HE-480C-GC

Carbon Sensor Conductivity Meter (Low concentration type)

HE-480H
More HE-480H

Panel-mount Type Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HE-480R
More HE-480R

Panel-mount Type Resistivity Meter(Four-Wire Transmission)

HE-480R(W)
More HE-480R(W)

Industrial resistivity meter

HE-960CA
More HE-960CA

Citric Acid Monitor

HE-960CW
More HE-960CW

Panel-mount Type Conductivity Meter (Four-Wire Transmission, 2-channel)

HE-960H-TM
More HE-960H-TM

Wide range TMAH Concentration Monitor

HE-960H-TM-S
More HE-960H-TM-S

High Precision TMAH Concentration Monitor

HE-960HC
More HE-960HC

Carbon Sensor Conductivity Meter (High concentration type)

HE-960HI
More HE-960HI

Panel-mount Type Conductivity Meter (Four-Wire Transmission, For Wide Range)

HE-960LC
More HE-960LC

Carbon Sensor Conductivity Meter

HE-960LF / FS-09F-1/2
More HE-960LF / FS-09F-1/2

Flat Carbon Sensor Conductivity meter

CS-100 Series
More CS-100 Series

Stand-alone Type Chemical Concentration Monitor

CS-100F1 Series
More CS-100F1 Series

Fiber Optic Type Chemical Solution Concentration Monitor

CS-600F
More CS-600F

Fiber Optic Type Chemical Concentration Monitor

CS-700
More CS-700

High Precision, High Stability Chemical Concentration Monitor

CS-900
More CS-900

Non-Contact Chemical Concentration Monitor

EG-100
More EG-100

Washwater Monitoring System

HF-960M
More HF-960M

Low Concentration Type HF/HCl/NH3 Concentration Monitor

HU-200SS
More HU-200SS

Field-installation Type MLSS Meter (Four-Wire Transmission)

HU-200TB-H
More HU-200TB-H

Field-installation Type Turbidity Meter (Four-Wire Transmission, High-sensitivity)

HU-200TB-IM
More HU-200TB-IM

Field-installation Type Turbidity Meter (Four-Wire Transmission, Immersion Type)

HU-200TB-W
More HU-200TB-W

Field-installation Type Turbidity Meter (Four-Wire Transmission, For Wide Range)

HZ-960
More HZ-960

Dissolved Ozone Monitor

OPSA-150
More OPSA-150

Organic Pollutant Monitor

TPNA-500
More TPNA-500

Automatic Total Nitrogen/Phosphorus Monitoring

U-50
More U-50

Multi-parameter Water Quality Checker

VUV Transmission
More VUV Transmission

Use of H20UVL for VUV transmission