FTX-ONE-CL

FTIR Exhaust Gas Analyzer for Dilute Emissions Measurement

Measuring diluted exhaust can require engineers to monitor numerous regulated and unregulated compounds at low concentrations while keeping the results synchronized throughout a test cycle. The FTX-ONE-CL provides accurate, simultaneous measurement of up to 28 components in diluted engine exhaust, including nitrogen compounds, greenhouse gases, aldehydes, alcohols and hydrocarbons.

Using Fourier Transform Infrared (FTIR) spectroscopy and multivariate analysis, the analyzer consolidates multi-component measurement into one compact system. Its 5 Hz sampling rate captures changing concentrations during transient engine and vehicle tests, helping development teams investigate emissions behavior without coordinating data from multiple individual analyzers.

Designed for integration with constant volume sampling and test automation systems, the FTX-ONE-CL supports diluted-exhaust mass calculations. Its low sampling flow rate minimizes the amount of gas withdrawn from the bag line, while its compact footprint provides greater flexibility for installation in new and existing laboratories.

As part of HORIBA ONE PLATFORM, the FTX-ONE-CL can be integrated with other compatible HORIBA measurement systems through a common user interface. This enables centralized control, monitoring and management of emissions measurement equipment while supporting consistent laboratory operation and future system expansion.

Simultaneous Measurement of Up to 28 Components

The FTX-ONE-CL allows engineers to evaluate multiple exhaust gas components using synchronized data from a single analyzer.

  • Simultaneously measures up to 28 components, depending on the selected configuration
  • Measures nitrogen compounds, greenhouse gases, aldehydes, alcohols and hydrocarbons
  • Supports standard component sets for gasoline and diesel vehicles, as well as CNG applications
  • Configurable measurement components and ranges based on testing requirements
  • Reduces the need to coordinate results from multiple individual analyzers
  • Supports detailed emissions characterization across different fuels and powertrain technologies


Fast FTIR Measurement for Transient Testing

FTIR spectroscopy combined with HORIBA’s multivariate analysis algorithm enables rapid, simultaneous analysis of complex diluted exhaust gas mixtures.

  • 5 Hz sampling rate for observing transient concentration changes
  • Synchronized measurement of multiple compounds throughout a test cycle
  • Supports analysis of cold-start, acceleration and other dynamic operating events
  • Provides engineers with time-resolved data for correlating emissions with vehicle, engine and aftertreatment behavior


Diluted Exhaust Measurement and Mass Calculation

The analyzer is designed for integration into diluted exhaust measurement systems used for engine and vehicle testing.

  • Measures diluted exhaust from internal-combustion engines
  • Integrates with a constant volume sampling system and test automation system
  • Supports emissions mass calculations using measured concentrations and dilution-system data
  • Enables continuous-line and bag-line measurement
  • Supports coordinated data acquisition and evaluation across the test system


Integrated with HORIBA ONE PLATFORM

As part of HORIBA ONE PLATFORM, the FTX-ONE-CL provides a consistent operating environment across compatible HORIBA measurement systems.

  • Operate compatible measurement devices through a common user interface
  • Centralize equipment control, monitoring and management
  • Integrate the analyzer into a coordinated emissions measurement system
  • Support consistent operating procedures across laboratories and test cells
  • Simplify access to analyzer status and measurement information
  • Expand the measurement system as laboratory requirements evolve
  • Discover how HORIBA ONE PLATFORM connects and manages laboratory measurement systems.


Low Sampling Flow Rate

The FTX-ONE-CL minimizes the amount of sample required from the diluted exhaust measurement system.

  • Approximately 1.0 L/min sampling flow from the bag line
  • Approximately 3.0 L/min sampling flow from the continuous line
  • Reduces sample withdrawal from bags during analysis
  • Facilitates integration into existing diluted exhaust and bag-sampling systems


Compact Design for Laboratory Integration

The compact analyzer provides greater flexibility when adding multi-component FTIR measurement to new or existing laboratories.

  • Approximately half the installation footprint and weight of the referenced previous configuration*
  • Dimensions of 438 × 765 × 950 mm, excluding protrusions
  • Greater flexibility when planning equipment layouts
  • Easier integration where laboratory space is limited
  • Improved access for operation and maintenance


*Footprint comparison. The exact comparison model should be identified if product management can provide it; otherwise, the “half” claim lacks a clear reference point.


Research and Development Applications

The FTX-ONE-CL supports emissions research, vehicle and engine development, fuel evaluation and regulatory testing involving diluted exhaust gas.

  • Engine and vehicle emissions research and development
  • Diluted exhaust analysis using CVS and bag-sampling systems
  • Cold-start and transient emissions investigation
  • Exhaust aftertreatment development and evaluation
  • Alternative-fuel and low-carbon-fuel research
  • Gasoline and diesel vehicle development
  • CNG and natural-gas engine development
  • Aldehyde and alcohol measurement, including formaldehyde and ethanol
  • Greenhouse-gas measurement, including methane and nitrous oxide
  • Development and evaluation related to U.S. EPA requirements
  • Measurement methods associated with GTR No. 15
  • R&D in preparation for Euro 7 requirements


Supporting Current and Emerging Emissions Requirements

Depending on its configuration, the FTX-ONE-CL supports measurement applications associated with:

  • U.S. EPA LDV Tier 3 N2O certification testing
  • NMOG certification for natural-gas vehicles
  • NMNEHC certification for stationary natural-gas engines
  • GTR No. 15 measurement methods for components such as formaldehyde, ethanol and nitrous oxide
  • Engine and vehicle R&D in preparation for Euro 7 requirements

 

Measurement capabilities and applicable configurations vary. Contact HORIBA to confirm the appropriate component set, measurement ranges and regulatory application.

FTX-ONE-CL
Measurement targetExhaust gas from internal combustion engine (Dilute measurement)
Target components*1Max. 28 components
Target components sets*2Standard set : Gasoline / Diesel vehicle
CNG set
PrincipleFourier Transform Infrared (FTIR)
Sampling line temperature113 °C ± 3 °C
Sampling gas flow rateContinuous line: Approx. 3.0 L/min
Bag line: Approx. 1.0 L/min
Operating environmentAmbient temperature 5 - 40 °C
Ambient humidity: less than 80 % relative humidity (non condensing)
Power requirements*3Approx. 2.8 kVA as MAX.,
Approx. 2.2 kVA at stable state
Dimensions*4438(W) × 765(D) × 950(H) mm
Mass*4Approx.160 kg

*1:Select when ordering from the “Measuring Components and Ranges” table
*2:Standard combination of components and ranges, specified at time of order
*3:With heated filter, heated hose (15 m)
*4:Excluding protrusions

Measuring Components and Ranges*1

ComponentsStandard
CO0-100ppm
0-500ppm
0-2500ppm
0-1 vol%
0-5 vol%
CO20-5000ppm
0-2 vol%
0-10 vol%
NO0-100ppm
0-500ppm
0-2500ppm
NO20-100ppm
N2O0-20ppm
0-100ppm
H2O0-15 vol%
NH30-100ppm
0-500ppm
SO20-100ppm
HCHO*20-50ppm
HCOOH0-50ppm
CH3OH0-100ppm
C2H5OH0-50ppm
0-100ppm
CH3CHO0-50ppm
CH40-250ppm
C2H40-100ppm
C2H60-100ppm
1,3-C4H60-100ppm
iso-C4H80-100ppm
C6H60-250ppm
C7H80-250ppm
NOx / HC sumSum

*1: The following are optional: Add other components (methanol, ethanol, acetaldehyde, MTBE, DME, acetone and acetic acid), to interchange other components and to change ranges. Please contact HORIBA for optional arrangements.
*2: Reference component

Informationsanfrage

Sie haben Fragen oder Wünsche? Nutzen Sie dieses Formular, um mit unseren Spezialisten in Kontakt zu treten.

* Diese Felder sind Pflichtfelder.

Verwandte Produkte

9618N-10D Micro ToupH Electrode
9618N-10D Micro ToupH Electrode

Electrode for Low-Volume Samples

CVS-ONE
CVS-ONE

Constant Volume Sampler

EXFM-ONE
EXFM-ONE

Ultrasonic Exhaust Flow Meter for Real-Time Emissions Measurement

FTX-ONE-CS/RS
FTX-ONE-CS/RS

FTIR Exhaust Gas Analyzer for Direct Exhaust Measurement

MDLT-ONE
MDLT-ONE

Micro Dilution Tunnel

MEXA-1170HCLD
MEXA-1170HCLD

Heated Type NOx Analyzer

MEXA-1170HFID
MEXA-1170HFID

Heated Type THC Analyzer

MEXA-1170SX
MEXA-1170SX

Motor Exhaust Gas Sulfur Analyzer

MEXA-1300R
MEXA-1300R

Motor Exhaust Gas Analyzer

MEXA-2000SPCS series
MEXA-2000SPCS series

Solid Particle Counting System

MEXA-584L
MEXA-584L

Automotive Emission Analyzer

MEXA-730λ
MEXA-730λ

Air-to-fuel Ratio Analyzer

MEXA-ONE
MEXA-ONE

Motor Exhaust Gas Analyzer for Engine & Vehicle Testing

MEXA-ONE-FT
MEXA-ONE-FT

FTIR Motor Exhaust Gas Analyzer

MEXA-ONE-QL-NX
MEXA-ONE-QL-NX

Laser Spectroscopic Analyzer for NOx & NH3 Measurement

OBS-ONE GS Unit
OBS-ONE GS Unit

On-board Emissions Measurement System

OBS-ONE PM unit
OBS-ONE PM unit

On-board Emissions Measurement System

OBS-ONE PN Unit
OBS-ONE PN Unit

On-board Emissions Measurement System

OBS-ONE SPN10 Unit
OBS-ONE SPN10 Unit

On-board SPN10 measurement for real-world

OBS-ONE-XL (IRLAM)
OBS-ONE-XL (IRLAM)

On-board NH3/N2O Measurement System for real-world driving

PTFM-1000V2
PTFM-1000V2

Pitot Tube Exhaust Flow Meter

PTFM-ONE-DT
PTFM-ONE-DT

Dual Pitot Tube Exhaust Flow Meter

Torque Matching
Torque Matching

Road-to-Rig Chassis Dyno Replication

51 series
51 series

Explosion-proof Gas Analyzer

AP-370 Series
AP-370 Series

Air Pollution Monitor

APCA-370
APCA-370

Ambient Carbon Dioxide Monitor

APHA-370
APHA-370

Hydrocarbon Monitor / THC Analyser

APMA-370
APMA-370

Ambient Carbon Monoxide Monitor

APNA-370
APNA-370

Ambient NOx Monitor

APOA-370
APOA-370

Ambient Ozone Monitor

APOA-380WM
APOA-380WM

Ozone Monitor (Wall Mount Type)

APSA-370
APSA-370

Ambient Sulfur Dioxide Monitor

AQMS
AQMS

Ambient Air Quality Monitoring System

CEMS
CEMS

Continuous Emission Monitoring System

ENDA-5000 series
ENDA-5000 series

Stack Gas Analysis System

FTX-ONE-CS/RS
FTX-ONE-CS/RS

FTIR Exhaust Gas Analyzer for Direct Exhaust Measurement

GA-370
GA-370

Trace Gas Monitor

GI-700 series
GI-700 series

Stack Gas Analyzer

IR-300 Series
IR-300 Series

Vapor Concentration Monitor

IR-400 Series
IR-400 Series

High-grade type Gas Monitor for Chamber Cleaning End Point Monitoring

MEXA-1170HCLD
MEXA-1170HCLD

Heated Type NOx Analyzer

MEXA-1170HFID
MEXA-1170HFID

Heated Type THC Analyzer

MEXA-1170SX
MEXA-1170SX

Motor Exhaust Gas Sulfur Analyzer

MEXA-1300R
MEXA-1300R

Motor Exhaust Gas Analyzer

MEXA-584L
MEXA-584L

Automotive Emission Analyzer

MEXA-ONE-FT
MEXA-ONE-FT

FTIR Motor Exhaust Gas Analyzer

MEXA-ONE-QL-NX
MEXA-ONE-QL-NX

Laser Spectroscopic Analyzer for NOx & NH3 Measurement

OBS-ONE GS Unit
OBS-ONE GS Unit

On-board Emissions Measurement System

OBS-ONE-XL (IRLAM)
OBS-ONE-XL (IRLAM)

On-board NH3/N2O Measurement System for real-world driving

PG-300 series
PG-300 series

Portable Gas Analyzer

PI-200-DP
PI-200-DP

Dual-Point Process Raman Analyzer

PI-200-L
PI-200-L

QC/QA Raman Laboratory Analyzer

PI-200-SP
PI-200-SP

Single Point Process Raman Analyzer

Process
Process

Process Analyzer System

VA-5000 / VA-5000WM Series
VA-5000 / VA-5000WM Series

Multi-Component Gas Analyzer

Corporate