Centro de Descargas

» Catalogos  » Manuales de Utilización  » Software

Catalogos

Manuales de Utilización por Productos

  1. Select a product from the following product list.
  2. Download materials will be displayed on a product page in the Downloads tab*. To find model-specific materials, you may need to select a specific product model from the product variants list after selection of a product series. Product variants (if available) are displayed below overall information of a product series.
    * Please note that the downloads tab may not be shown, if no materials are currently available for download on a product you have selected.
  3. Click or tap a title of material to initiate download. If requested, fill out a form in order to receive your personal download link.

Select a product to find download materials:

LAQUA PH1100
LAQUA PH1100

Benchtop Water Quality Meters

LAQUA PH1200
LAQUA PH1200

Benchtop Water Quality Meters

LAQUA PH1300
LAQUA PH1300

Benchtop Water Quality Meters

LAQUA EC1100
LAQUA EC1100

Benchtop Water Quality Meters

LAQUA PC1100
LAQUA PC1100

Benchtop Water Quality Meters

LAQUA F-72
LAQUA F-72

Benchtop pH/ORP/Ion/Temperature Meter

LAQUA F-73
LAQUA F-73

Benchtop pH/ORP/Ion/Temperature Meter

LAQUA F-74
LAQUA F-74

Benchtop pH/ORP/Ion/Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUA DS-72
LAQUA DS-72

Benchtop Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

Select a product to find download materials:

LAQUA WQ-310-K
LAQUA WQ-310-K

Handheld Water Quality Meters

LAQUA WQ-320-K
LAQUA WQ-320-K

Handheld Water Quality Meters

LAQUA WQ-330-K
LAQUA WQ-330-K

Handheld Water Quality Meters

LAQUA PH210
LAQUA PH210

Handheld pH/ORP/Temperature Meter

LAQUA PH220
LAQUA PH220

Handheld pH/ORP/Temperature Meter

LAQUA EC210
LAQUA EC210

Handheld Conductivity/Resistivity/Salinity/Total Dissolved Solids/Temperature Meter

LAQUA EC220
LAQUA EC220

Handheld Conductivity/Resistivity/Salinity/Total Dissolved Solids/Temperature Meter

LAQUA DO210
LAQUA DO210

Handheld Dissolved Oxygen/Temperature Meter

LAQUA DO220
LAQUA DO220

Handheld Dissolved Oxygen/Temperature Meter

LAQUA PC220
LAQUA PC220

Handheld pH/ORP/Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUA PD210
LAQUA PD210

Handheld pH/ORP/Dissolved Oxygen/Temperature Meter

LAQUA PD220
LAQUA PD220

Handheld pH/ORP/Dissolved Oxygen/Temperature Meter

Select a product to find download materials:

LAQUAtwin pH-11
LAQUAtwin pH-11

Medidores de Bolsillo

LAQUAtwin pH-22
LAQUAtwin pH-22

Pocket Water Quality Meters

LAQUAtwin pH-33
LAQUAtwin pH-33

Pocket Water Quality Meters

LAQUAtwin EC-11
LAQUAtwin EC-11

Pocket Water Quality Meters

LAQUAtwin EC-22
LAQUAtwin EC-22

Pocket Water Quality Meters

LAQUAtwin EC-33
LAQUAtwin EC-33

Pocket Water Quality Meters

LAQUAtwin Na-11
LAQUAtwin Na-11

Pocket Water Quality Meters

LAQUAtwin K-11
LAQUAtwin K-11

Pocket Water Quality Meters

LAQUAtwin NO3-11C/NO3-11S/NO3-11
LAQUAtwin NO3-11C/NO3-11S/NO3-11

Pocket Water Quality Meters

LAQUAtwin Ca-11
LAQUAtwin Ca-11

Pocket Water Quality Meters

LAQUAtwin Salt-11
LAQUAtwin Salt-11

Pocket Water Quality Meters

LAQUAtwin Salt-22
LAQUAtwin Salt-22

Pocket Water Quality Meters

LAQUAtwin Ca-11C
LAQUAtwin Ca-11C

Pocket Water Quality Meters

Select a product to find download materials:

Glass Electrode 1076A-10C
Glass Electrode 1076A-10C

For measurement of low-conductivity water and non-aqueous solvents.

Software

This software can load measured data from pH Meters, F-70 series, Conductivity Meters, DS-70 series, and Portable pH/Water Quality Meters D-70/ES-70/OM-70 series into your PC and save the data in MSD format or BME format or CSV format. Files of MSD format and BME format are the binary files that only open by this software.

System component

Component

Description

Meter

F-71/72/73/74/74BW, DS-71/72, D-72/73/74/75, ES-71, OM-71

PC

Refer to "2.4 Necessary PC environment and recommended PC environment"

Serial cable

Optional for Meter(Part No. 3014030151)

USB cable

Optional for Meter(Part No. 3200373941)

Communication method

Serial and USB communication
By connecting cable, real-time measurement (reger to "8 Measurement Mode") are enabled as well as the data memorized in the Meter can be acquired by PC (refer to "9 Memory data Mode")

Note

  • The serial communication and the USB communication cannot be used at the same time.
  • The following models can use only serial communication.
    • D-70 series,  ES-71, OM-71

 

Necessary PC environment and recommended PC environment

The following shows the necessary PC environment and recommended PC environment for this software.
Necessary PC environment: The following PC environment is necessary to use this software.
Recommended PC environment: The following PC environment is recommended to use this software comfortably.

Component

Necessary PC environment

Recommended PC environment

Memory

32 bit: 1 GB or more
64 bit: 2 GB or more

CPU

1 GHz or more

Free space of HDD

5 GB or more

10 GB or more

OS

Windows 7, Windows 8 (8.1), and Windows 10

Display

SUPER VGA (800×600) or more

Connector

Serial connector (D-SUB 9 pin)

USB connector

When this software is used in the condition in which memory or the free space of hard disk is in short, the software may freeze during use and the data cannot be saved.

FD-70(E) instruction manual

Data Collection Software FD-70 Instruction Manual(GZ0000276836D) 0.9MB

Data Collection Software FD-70

For U-50 Series

Please download all attached files, and install the software (section 3.1 of the manual) and drivers (section 3.2 of the manual).

Water & Liquid Corporate