Partica LA-960V2

LA-960V2

Laser Scattering Particle Size Distribution Analyzer

Premium performance particle size analyzer using advanced laser diffraction technology: Combining measurement excellence with versatility.

The latest evolution in the highly popular HORIBA LA series the LA-960V2 is the ideal tool for measuring particle size distributions in powders, granules, suspensions, emulsions, slurries, pastes and gels. It has been designed to meet the demands of both routine QC analysis as well as R&D and more in-depth product or process understanding.

  • Exceptional particle size range on one optical platform, 10nm to 5mm
  • Wide range of wet and dry sample dispersion options
  • Rapid dispersion unit changeover system with no extra bench footprint
  • Particle imaging accessory for deeper particle understanding
  • Robust and reliable particle size results
Segment: Scientific
Manufacturing Company: HORIBA, Ltd.

HORIBA’s groundbreaking optical design perfects the static light scattering particle sizing technique.

Advanced Detector Design

The number of detectors, angular range, and layout each contribute to overall system performance.

Superior Instrument-to-Instrument Precision

The LA-960V2 is designed and built to provide the same experience regardless of manufacture date, operator skill, or geographic location. Achieve unmatched instrument agreement without the hassle of correlation.

Automatic Laser Alignment in Seconds

Always make perfect measurements with computer-controlled laser alignment. The alignment process is finished in only a few seconds with HORIBA's innovative approach.

Guaranteed Accuracy and Precision

The LA-960V2 is a highly refined particle size analyzer capable of accurately measuring NIST-traceable size standards within 0.6% of specification. Fully compliant with ISO 13320 recommendations regarding the measurement of materials on the D10, D50, and D90.


State of the Art Sampling Systems

Wet Measurement

Sample-to-sample analysis in less than 60 seconds

The HORIBA LA-960V2 wet circulation system is an easy, fast and very powerful dispersion system. The standard wet system offers a full package of a dispersant fill pump, liquid level sensor, circulation pump, 30 W in-line ultrasonic probe, and drain valve, which is all software-controlled for true one-button operation. This advanced design provides highly reproducible particle size results.

Dry Measurement

Automated, powerful dry-powder dispersion

The LA-960V2 PowderJet combines several unique and patented features to provide the most reproducible dry measurements. Use the Auto Measurement function to control vacuum, air pressure, powder flow, start/stop conditions, measurement duration, and data processing. Designed to handle every application including small sample amounts, friable powders, and highly agglomerated materials.

  • Smart Scans – Trigger function
    This function allows for very precious materials to be measured accurately. When the sample amount is limited or low flow ability, the Trigger functions perfectly to start and stop the measurement.
  • Self-Adjusting Powder Flow
    Historically, the biggest challenge in dry powder measurement involved establishing an even powder flow. The LA-960V2 PowderJet has solved that challenge with a self-adjusting feedback loop to maintain a constant laser transmittance. This is a crucial factor in creating reliable, reproducible dry powder size measurements.

LY-9610 Imaging Unit

The imaging unit allows real-time observation, particle image acquisition, and assessment of the particles in the wet circulation system. It is small and integrated in the main unit without increasing instrument footprint!

Features

  • Detect and count even with trace amounts of unusual particles (Contaminants, large particles and aggregated particles)
  • Detect bubbles in wet circulation system.
  • Improved understanding of sample dispersion (effect of stirring, sonication, addition of surfactants, stabilizers, etc.)
  • Particle shape analysis* (Optional Advanced Software)

 

Functions

  • Image acquisition and particle detection.
  • Automatic detection of large particles.
  • Automatic detection of bubbles.
  • Real time trend graph and histogram of equivalent circular diameter.
  • Histogram of shape distribution (aspect ratio, roundness, length, width) with optional advanced software.

 

Interview with Rob Lee of Particle Sciences (1:58)
Watch a two minute video detailing how HORIBA Scientific has partnered with Particle Sciences to provide world-class technology and support for their CDMO business.

Laser scattering particle size distribution analyzer Model: LA-960V2

Measurement Principle

Mie scattering and Fraunhofer diffraction

Measurement range

10 nm - 5000 μm

Measurement Time

Typical measurement takes 60 seconds from liquid filling, sampling and measurement to rinsing.

Measurement Method

Circulation measurement or fraction cell measurement (Fraction cell is optional)

Sample Quantity

Approximately 10 mg - 5 g (Depending on the particle size, distribution and density)

Dispersing Volume

Approximately 180 mL for standard pumping system, 5/10/15 mL for FractionCell accessory, Manual filling : 35 mL, Automatic filling : 40 mL for MiniFlow accessory. Approximately 1 L of LiterFlow option.

Available carrier fluid

Aqua* (A type), Organic solvent (S type) (*Ethanol can be used as a dispersing additive)

Communication

USB 2.0

Light Sources

Red solid state 5 mW laser diode (650 nm), Blue solid state 3 mW LED (405 nm)

Dispersion System

In-line ultrasonic probe: 30 W, 20 kHz, adjustable levels
Circulation pump: Fully automated fill and circulation pumps, 15 adjustable speeds, 4 selectable fill levels, 15 selectable circulation speeds (max: 10 L/min)

Operating Conditions

15〜35°C (59 to 95°F), relative humidity 85% or less (no condensation)

Power

AC 100-240V 50/60Hz, 300VA

Dimensions

705 (W) × 565 (D) × 500 (H) mm

Mass

54 kg

Computer Requirements

PC operation, Software compatible with Windows® 10 32-bit and 64-bit environments,
*contact HORIBA for additional operating system compatibilities

※Windows is a registered trademark of Microsoft Corporation in the United States and other countries.

 


PowderJet Dry Feeder Accessory

Dispersion Method

Compressed air dispersion using Venturi nozzle

Sample Delivery

Vibrating feeder

Sample Disposal

Vacuum-driven evacuation

Measurement range

100 nm - 5000 μm

Controls

Communication: Serial cable to LA-960V2 main unit
Measurement: Vibrating feeder controlled automatically via feedback or manually by user, Vacuum AUTO/OFF, Compressed Air AUTO/OFF, Air pressure adjustable from 0 - 0.4 MPa in 40 steps

Measurement Time

Typical measurement takes 2 seconds or longer.

Operating Conditions for PowderJet

15〜35°C (59 to 95°F), relative humidity 85% or less (no condensation)

Dimensions

332 (W) × 321 (D) × 244 (H) mm (not including dimensions of projections and LA-960V2 measurement unit)

Power for PowderJet Operation

AC 100V, 120V, 230V, 50 or 60Hz, 1500VA (Including vacuum but LA-960V2 measurement unit)

Compressed Air Supply Pressure

Compressed air supply origin pressure: 0.4 - 0.8 MPa
Compressed air controlling range: 0.01 - 0.4 MPa

Compressed Air Connection

Quick connector for resin tube with 6 mm outer diameter
(Compressed air supply equipment must be provided separately)

Remarks

Vacuum is equipped as standard

※When ordering the PowderJet, please specify the power requirements for the final destination.
※Above specifications and functionality are valid only when PowderJet is installed on the LA-960V2 main unit and controlled using the LA-960V2 software.
※Manufacturers and models indicated for vacuum, air compressor, computer, monitor, and/or printer are subject to change.

◎Air Compressor
Inlet pressure within 0.5 - 038 MPa, Tank capacity 26 L or larger, Flow rate 45 L/min or faster

 


LY-9610 Imaging Unit

Measureable Range for image analysis9 - 1000 μm
Pixel Size0.73 μm
Speed≧ 4 fps
FunctionsHistogram of equivalent circle diameter.
Shape Parameters: Aspect ratio*, Circularity*, Length*, Width*
Trend graph of equivalent circle diameter.
Post Analysis of captured image (zoom-in/out, measuring size).

  *Optional Advanced software


Accessories

Components
 
LA-960N2LA-960A2LA-960S2LA-960W2LA-960L2
OpticsStandard optical system
Aqua type Ethanol can be used as a dispersing additive. (0.01 - 3000 μm)   


 
Standard circulation system----
Pressurized fill adapter----
Liter flow----
Peristaltic pump system----
Solvent type(0.01 - 3000 μm)Standard pump system----
Accessories



 
Fraction cell holder
Mini-Flow with ultrasonic unit (0.01 - 1000 μm)
Paste cell holder
Dry unit (0.1 - 5000 μm)
Auto sampler-
High Concentration Cell

External Dimensions (mm)

Maximizing Soy Milk Quality Attributes through Particle Size Analysis
Maximizing Soy Milk Quality Attributes through Particle Size Analysis
In this note, the final result of soy milk processing is evaluated with particle size analysis. Particle size results give a quantitative measure of the soy milk that can be used to ensure consistent production and product quality.
Particle Analysis of Mayonnaise
Particle Analysis of Mayonnaise
This application note reviews the important role that particle size plays in the formation of mayonnaise and mayo products and how changes affect the taste and consistency of these alternatives.
Material Characterization of the Next Generation Sugar Substitutes
Material Characterization of the Next Generation Sugar Substitutes
This study focuses on the critical particle diameter of dry sugar granules as particle diameter is an indicator of: Flowability, Dissolution and mixing, and Powder uniformity.
Particle Size Analysis of Piezoelectric Ceramics
Particle Size Analysis of Piezoelectric Ceramics
This application note shows how the laser diffraction technique can be effectively used as an inspection tool for the synthesis of piezoelectric ceramics.
Laser Diffraction Analysis of Lithium Ion Battery Material
Laser Diffraction Analysis of Lithium Ion Battery Material
Battery technology is improving, keeping up with the demand for better power storage. Improved performance requires greater control of the materials used and their physical properties including the particle size distribution.
Pigment Particle Size and Hiding Power
Pigment Particle Size and Hiding Power
Pigment size can be readily measured by laser diffraction. This measurement requires less time, training and effort than a color strength measurement and provides useful information for the process engineer.
Titanium Dioxide Particle Size
Titanium Dioxide Particle Size
Titanium Dioxide (TiO2) is a pigment used in paints and many other applications. The particle size of titanium dioxide directly impacts its performance in numerous applications, necessitating the measurement and control of this important property.
Analysis of Biopolymers with Laser Diffraction
Analysis of Biopolymers with Laser Diffraction
This application note describes two experiments where laser diffraction proved capable of determining both the base biopolymer nanoparticles and also larger particles outside of the range of DLS.
Particle Analysis of Gold Nanoparticles
Particle Analysis of Gold Nanoparticles
Nanoparticle gold is a suspension of sub-micron gold particles typically dispersed in water. Gold nanoparticles are of great interest for researchers in many fields due to their unique physical and optical properties. These properties change with the particle size distribution, so size analysis is an important measurement requirement.
Particle Analysis of CMP Slurries
Particle Analysis of CMP Slurries
The abrasive particles found in CMP slurries have a size distribution which directly affects critical metrics. Particle size analysis is therefore a key indicator of CMP slurry performance. The popularity and utility of several particle sizing techniques will be discussed within.
Particle Characterization of Nutraceutical Products
Particle Characterization of Nutraceutical Products
Laser diffraction particle size analyzers offer the same benefits in speed, precision, and reliability to nutraceutical materials that have made the technique popular in the pharmaceutical industry.
Particle Analysis for Cosmetics
Particle Analysis for Cosmetics
Many cosmetic products include particulate material or emulsions. Some examples of cosmetic products consisting of or including particulates include facial powders, moisturizers, and lipstick. The particle size distribution of these components effects appearance, stability, and protection.
Particle Size of Electronic Ceramic Powders
Particle Size of Electronic Ceramic Powders
Particle size analysis plays a crucial role in the manufacture of electronic materials for dielectric applications. In all cases, the particle size distribution has a great impact on their processing and performance.
Laser Diffraction Particle Size Analysis of Solid Oxide Fuel Cell Materials
Laser Diffraction Particle Size Analysis of Solid Oxide Fuel Cell Materials
Particle size is of critical importance to the powder properties and to the performance of solid oxide fuel cells. Laser diffraction has proven to be an excellent way to monitor and control particle size for these materials.
Measuring Organic Pigments with Laser Diffraction
Measuring Organic Pigments with Laser Diffraction
Particle size is a critical physical characteristic of pigments and laser diffraction is the most popular method of particle size analysis for the milling process, allowing close control and optimization of a number of final product performance criteria.
Laser Diffraction Analysis of Soils and Sediments
Laser Diffraction Analysis of Soils and Sediments
Measurement of the particle size of soil and sediment sample is a critical part of understanding the geological history of a particular area.

Request for Information

Do you have any questions or requests? Use this form to contact our specialists.

* These fields are mandatory.

Related products

nanoPartica SZ-100V2 Series
nanoPartica SZ-100V2 Series

Nanoparticle Analyzer

Partica LA-960V2
Partica LA-960V2

Laser Scattering Particle Size Distribution Analyzer

Partica mini LA-350
Partica mini LA-350

Laser Scattering Particle Size Distribution Analyzer

ANALYSETTE 28 ImageSizer*
ANALYSETTE 28 ImageSizer*

Dynamic Image Analysis

nanoPartica SZ-100V2 Series
nanoPartica SZ-100V2 Series

Nanoparticle Analyzer

Partica CENTRIFUGE
Partica CENTRIFUGE

Centrifugal Nanoparticle Analyzer

Partica LA-960V2
Partica LA-960V2

Laser Scattering Particle Size Distribution Analyzer

Partica mini LA-350
Partica mini LA-350

Laser Scattering Particle Size Distribution Analyzer

ViewSizer 3000
ViewSizer 3000

Simultaneous Multi-Laser Nanoparticle Tracking Analysis (NTA)

APDA-372
APDA-372

Ambient Dust Monitor

Partica LA-960V2
Partica LA-960V2

Laser Scattering Particle Size Distribution Analyzer

Partica mini LA-350
Partica mini LA-350

Laser Scattering Particle Size Distribution Analyzer

PD10
PD10

Reticle / Mask Particle Detection System