HD-200

현장설치형 용존산소측정기(4-Wire Transmission), 멤브레인형)

HD-200은 DO(용존산소) 센서(DO-1100)를 연결하여 시료수의 용존산소량을 측정합니다.
측정 방식은 멤브레인 방식의 폴라로그래피 방식입니다.
폐수 처리 또는 양식용 수족관의 DO 모니터링에 적합 합니다.

- 측정 범위 (용존 산소 농도) : 0 ~ 20 mg/L
- 포화도 : 0 ~ 200%
- 온도 : 0 ~ 50℃

Division: Process Water
Manufacturing Company: HORIBA Advanced Techno Co., Ltd.

Tough

  • Responds to harsh conditions at the site process
      Operating temperature range(Transmitter):-20 - 55℃
      Rated power supply voltage:AC 90 - 264 V ±10% 50/60 Hz
      Robust aluminum die cast (Protection code:IP65)
  • CE Marking and FCC Compliance suitable for use at overseas sites

 

Intelligence

  • Self-diagnosis of membrane damage and infiltration into the probe
  • Convenient function to display liquid temperature at the same time(Transmission output available)
  • Designed to be environmentally friendly (Pb-free) in response to WEEE and RoHS

 

Easy maintenance

  • Easy to view big display
  • Easy operation
  • Calibration log memory
  • Screw terminals that do not fall off are used in the terminal block for wiring
  • On-site membrane replacement as well as whole sensor replacement
  • Span calibration by air preceded by auto-zeroing (Electrical auto zeroing function)
Product nameDissolved oxygen converter
ModelHD-200
Combined sensor5505, 5510 (A bipolar diaphragm type polarography sensor)
Combined probeDO-1100
Measurement
range
Dissolved oxygen
concentration
0 mg/L to 20 mg/L (Display range: 0 mg/L to 22 mg/L)
Saturation degree0% to 200% (Display range: 0% to 200%)
Temperature0℃ to 50℃ (Display range: -10℃ to 110℃)
Display
resolution
Dissolved oxygen
concentration
0.01 mg/L
Saturation degree1%
Temperature0.1℃
PerformanceDissolved
oxygen
concentration
RepeatabilityWithin ±0.5% of the full scale (response for equivalent input)
LinearityWithin ±0.5% of the full scale (response for equivalent input)
TemperatureRepeatability±0.5℃(response for equivalent input)
Linearity±0.5℃(response for equivalent input)
Transmission
output
Number of output2 (The negative terminals for transmission outputs are internally connected at the same electric potential)
Output type4 mA to 20 mA DC: input/output isolated type
Load resistanceMaximum: 900Ω
LinearityWithin ±0.08 mA (output only)
RepeatabilityWithin ±0.02 mA (output only)
Output rangeOutput 1Dissolved oxygen concentration: Selection from preset ranges or free range input within measuring range.
Output 2Free setting within a range between -20℃ and 130℃
Occasional out for errorHold or burnout to either 3.8 mA or 21 mA
Transmission holdIn the maintenance mode, transmission signal is held at the latest value or preset value.
In the calibration mode, transmission signal can be alive or held.
Contact outputNumber of output3
Output typeNo-voltage contact output
Contact typeRelay contact; SPDT (1c)
Output capacity250 V AC 3 A, 30 V DC 3 A (resistance load)
Contact
function
R1 and R2Selectable from upper limit alarm, lower limit alarm, ON/OFF control, currently holding of transmission output, and cleaning output (The contact is closed during alarm operation, opened normally and while the power is down).
FAILError alarm (Closed in the normal state, opened in the failure state or while the power is down.)
Alarm setting rangeSelectable from dissolved oxygen concentration, and temperature
  • Setting range: Within the measurement range
  • Delay time: 0 to 600 seconds
Control setting range
  • Setting range: 0 mg/L to 20 mg/L
  • Control width: 0.02 mg/L to 200 mg/L(±0.01 to ±0.50 mg/L)
Cleaning
output
Number of output points1
Output typeContact output with voltage (output of connected power supply voltage)
Contact typeRelay contact; SPST (1a)
Output contact capacity250 V AC 0.5 A
External instrumentSolenoid valve for cleaning control
SettingsCleaning period0.1 hours to 168.0 hours
Cleaning time2 seconds to 600 seconds
Hold time2 seconds to 600 seconds
Timer accuracyWithin 2 minutes per month
Description of cleaning
operation
One of the following operations.
  • Operation of internal timer only
  • Operation of internal timer and external input command
  • Enable the internal timer only when external input is active.
  • The cleaning trigger signal (The external trigger signal must be longer than 2 seconds)
Contact inputNumber of input1
Contact typeNo-voltage “a” contact of open collector
ConditionsON resistance: 100 Ω max.
Open voltage: 24 V DC
Short-circuit current: 12 mA DC max.
Contact functionExternal input for cleaning or transmission holding if cleaner is not attached.
Transmission
capability
Communication typeRS-485
Signal type2 wire system, isolated from the input circuit
Not isolated from transmission circuit
Temperature
compensation
Applicable temperature
element
Platinum resistor: 1 kΩ (0℃)
(The temperature sensor is built into the probe DO-1000.)
Temperature compensation
range
0℃ to 50℃
Temperature calibration1 point calibration comparing to reference thermometer
CalibrationCalibration methodSpan calibration in the air or DO saturated aquaous solution
Number of calibration pointsAtmospheric calibration: 1 point
(Zero electric calibration is carried out automatically)
Saturation liquid calibration : 2 points (zero calibration is omitted)
Additional capabilitiesSalinity compensation (0.0% to 5.0%)
Automatic detection of calibration failure (Zero error, Sensitivity error)
Calibration history (Elapsed days from the last calibration which ever zero or span, zero shift, span sensitivity)
Self-checkCalibration errorZero calibration error, sensitivity error, outside of temperature calibration range
Electrode diagnostic errorSensor error (damage to diaphragm), disconnection of sensor (or damage to sealing), temperature sensor short-circuit, and electric discontinuity of temperature sensor
meter errorCPU error, CPU error, ADC error, memory error
Operating temperature range-20℃ to 55℃ (without freeze)
Operating humidity rangeRelative humidity: 5% to 90% (without condensation)
Storage temperature-25℃ to 65℃
Power supplyRated power supply voltage100 V to 240 V AC ±10% 50/60 Hz
Power consumption15 VA (max)
OthersWith power switch for maintenance use
Compatible
standards
CE markingEMC  :EN61326-1
      Class A, Industrial electromagnetic environment
Safety  :EN61010-1
RoHS :EN50581
      9. Industrial monitoring and control instruments
FCC rulesPart15 Class A
StructureInstallationOutdoor installation type
Installation methodMounted on 50A pole or wall
Protection codeIP65IEC60529, JIS C0920
Case materialAluminum alloy (coated with epoxy-denatured melamine resin)
Material of fittingsSUS304
Material of hoodSUS304 stainless steel (coated with epoxy-denatured melamine resin)
Material of windowPolycarbonate
Display elementReflective monochrome LCD
External dimensions 180 (W) × 155 (H) × 115 (D) mm (excluding mounting brackets)
Mass Main body: Approx. 3.5 kg; cover and mounting brackets: Approx. 1 kg

*1:   The standard for effect on the reading by the electromagnetic field of the radiated radio frequency and by the conducted interference is within the measured dissolved oxygen value ±0.4 mg/L.

*2:   When the sensor cable, the transmission cable, or the contact input cable is extended to 30 m or longer, the surge test specified in the EMC directive for CE marking is not applied.

Note

An arrester (spark over voltage: 400 V) is implemented for transmission output, contact input, and communication. However, use a most suitable surge absorption element on the connection lines in accordance with the ambient environment, the situation of equipment installed, and the externally connected equipment.

제품 문의

HORIBA제품의 자세한 정보를 원하시면, 아래의 양식에 내용을 입력을 부탁드립니다.

* 는 필수입력항목입니다.

Related products

CS-620F
CS-620F

광섬유형 고온 인산 농도 모니터

CS-900
CS-900

비접촉 화학물질 농도 모니터

EMGA-Expert
EMGA-Expert

산소/질소/수소 분석기

EMGA-Pro
EMGA-Pro

산소/질소/수소 분석기

HC-200F
HC-200F

현장설치형 불소이온측정기(4-Wire Transmission)

HC-300F
HC-300F

현장설치형 불소이온측정기(2-Wire Transmission)

HD-200
HD-200

현장설치형 용존산소측정기(4-Wire Transmission), 멤브레인형)

HD-200FL (Four-Wire Transmission, 광학식)
HD-200FL (Four-Wire Transmission, 광학식)

현장 설치형 용존 산소 측정기

HD-300
HD-300

현장설치형 용존산소측정기(2-Wire Transmission), 멤브레인 형)

HD-480
HD-480

용존산소측정기(4-Wire Transmission), 멤브레인 형)

HD-960L
HD-960L

저농도 용존 산소 모니터

HD-960LR
HD-960LR

용존 산소 농도 모니터

HE-200C
HE-200C

현장설치형 전기전도도계(4-Wire Transmission, 저농도용)

HE-200H
HE-200H

현장설치형 전기전도도계(4-Wire Transmission, 고농도용)

HE-200R
HE-200R

현장 설치형 전기저항계(4-Wire Transmission)

HE-300C
HE-300C

현장 설치형 전기전도도계 (2-Wire Transmission, 저농도용)

HE-300C-IS ( 방폭형 )
HE-300C-IS ( 방폭형 )

방폭형 설치 타입 COND meter ( Low concentrtion )

HE-300R
HE-300R

현장 설치형 전기저항계(2-Wire Transmission)

HE-480C
HE-480C

패널 장착형 전도도계(4-Wire Transmission, 저농도용)

HE-480C-GC
HE-480C-GC

카본 센서 전도도계 (저농도형)

HE-480H
HE-480H

패널 장착형 전도도계(4-Wire Transmission,저농도용)

HE-480H-DC24V
HE-480H-DC24V

판넬 장착형 전도도계(4-wire Transmitter , 고전도도용)

HE-480R
HE-480R

패널 장착형 저항계(4-Wire Transmission)

HE-960CA
HE-960CA

구연산 모니터

HE-960CW
HE-960CW

패널 장착형 전도도계(4-Wire Transmission, 2채널)

HE-960H-KOH
HE-960H-KOH

KOH 모니터

HE-960H-TM-S
HE-960H-TM-S

고정밀 TMAH 농도 모니터

HE-960HC
HE-960HC

카본 센서 전도도계 (고농도형)

HE-960HI
HE-960HI

패널 장착형 전도도계(4-Wire Transmission, 광역용)

HE-960LC
HE-960LC

카본 센서 전도도계

HE-960LF / FS-09F-1/2
HE-960LF / FS-09F-1/2

평탄 카본 센서 전도도계

HE-960RW
HE-960RW

패널 장착형 저항계(4-Wire Transmission, 2채널)

HE-960RW-GC(W)
HE-960RW-GC(W)

2-채널 저항률계

HO-480
HO-480

패널 장착형 ORP 미터 (4-Wire Transmission)

HP-200 (Four-Wire Transmission)
HP-200 (Four-Wire Transmission)

현장 설치형 pH Meter

HP-300
HP-300

현장 설치형 pH미터 (2-Wire Transmission)

HP-480
HP-480

패널 장착형 pH미터 (4-Wire Transmission)

HP-480PL
HP-480PL

패널 장착형 pH 미터(4-Wire Transmission, 펄스 비례 제어)

HP-480TP
HP-480TP

패널 장착형 pH 미터(4-Wire Transmission, 산업용 시분할 비례제어)

HP-960FTP
HP-960FTP

패널 장착형 pH 미터(4-Wire Transmission, 4 포인트 알람, 시분할 비례 제어)

HR-200
HR-200

현장 설치형 잔류염소 측정기 (4-Wire Transmission, Water flow beads)

HR-200RT
HR-200RT

현장 설치형 잔류 염소 측정기 (4-Wire Transmission, Rotating Type)

HR-480
HR-480

잔류 염소 측정기 (4-Wire Transmission)

IT-470F-H
IT-470F-H

빌트인 타입 적외선 온도계

IT-545 Series
IT-545 Series

고정밀 적외선 온도계 (휴대용)

LAQUA PH210
LAQUA PH210

Handheld pH/ORP/Temperature Meter

TW-100
TW-100

자동 수질 측정장치

TW-150
TW-150

Online Water Quality Monitor (공정 수질 측정 시스템)

U-50 Series
U-50 Series

다항목 수질 측정기

UP-100
UP-100

마이크로 볼륨 pH 모니터

HD-200
HD-200

현장설치형 용존산소측정기(4-Wire Transmission), 멤브레인형)

HD-300
HD-300

현장설치형 용존산소측정기(2-Wire Transmission), 멤브레인 형)

HD-480
HD-480

용존산소측정기(4-Wire Transmission), 멤브레인 형)

HD-960L
HD-960L

저농도 용존 산소 모니터

HD-960LR
HD-960LR

용존 산소 농도 모니터

HE-200C
HE-200C

현장설치형 전기전도도계(4-Wire Transmission, 저농도용)

HE-200H
HE-200H

현장설치형 전기전도도계(4-Wire Transmission, 고농도용)

HE-200R
HE-200R

현장 설치형 전기저항계(4-Wire Transmission)

HE-300C
HE-300C

현장 설치형 전기전도도계 (2-Wire Transmission, 저농도용)

HE-300C-IS ( 방폭형 )
HE-300C-IS ( 방폭형 )

방폭형 설치 타입 COND meter ( Low concentrtion )

HE-300R
HE-300R

현장 설치형 전기저항계(2-Wire Transmission)

HE-480C
HE-480C

패널 장착형 전도도계(4-Wire Transmission, 저농도용)

HE-480C-GC
HE-480C-GC

카본 센서 전도도계 (저농도형)

HE-480H
HE-480H

패널 장착형 전도도계(4-Wire Transmission,저농도용)

HE-480H-DC24V
HE-480H-DC24V

판넬 장착형 전도도계(4-wire Transmitter , 고전도도용)

HE-480R
HE-480R

패널 장착형 저항계(4-Wire Transmission)

HE-960CA
HE-960CA

구연산 모니터

HE-960CW
HE-960CW

패널 장착형 전도도계(4-Wire Transmission, 2채널)

HE-960H-KOH
HE-960H-KOH

KOH 모니터

HE-960H-TM-S
HE-960H-TM-S

고정밀 TMAH 농도 모니터

HE-960HC
HE-960HC

카본 센서 전도도계 (고농도형)

HE-960HI
HE-960HI

패널 장착형 전도도계(4-Wire Transmission, 광역용)

HE-960LC
HE-960LC

카본 센서 전도도계

HE-960LF / FS-09F-1/2
HE-960LF / FS-09F-1/2

평탄 카본 센서 전도도계

HE-960RW
HE-960RW

패널 장착형 저항계(4-Wire Transmission, 2채널)

HE-960RW-GC(W)
HE-960RW-GC(W)

2-채널 저항률계

HF-700A
HF-700A

황산/과산화수소 모니터 (저농도)

HF-SP-CU
HF-SP-CU

2-채널 고정밀 HF 농도 모니터

HO-480
HO-480

패널 장착형 ORP 미터 (4-Wire Transmission)

HR-200
HR-200

현장 설치형 잔류염소 측정기 (4-Wire Transmission, Water flow beads)

HR-200RT
HR-200RT

현장 설치형 잔류 염소 측정기 (4-Wire Transmission, Rotating Type)

HR-480
HR-480

잔류 염소 측정기 (4-Wire Transmission)

HT-110
HT-110

총유기탄소 모니터

HZ-960HPO-M
HZ-960HPO-M

H2O2 모니터

T1 - TOCADERO Series
T1 - TOCADERO Series

온라인 TOC 분석기

TW-100
TW-100

자동 수질 측정장치

TW-150
TW-150

Online Water Quality Monitor (공정 수질 측정 시스템)

U-50 Series
U-50 Series

다항목 수질 측정기