X-5000*

Energy Dispersive X-ray Fluorescence Analyzer

HORIBA continues it's innovation in the petroleum market by proudly teaming with Olympus Innov-X to promote the X-5000 Mobile XRF Analyzer. The X-5000 is a rugged, fully integrated closed beam portable EDXRF system that offers the power and performance of a traditional benchtop XRF, but is designed for transportable operation. Using a Silicone Drift Detector, low PPM detection limits can be achieved for many elements in a variety of sample types and matrices. Applications include fuels, additives, and wear metal oils to crude oils, water, coke, and coal allow this easy to use analyzer to be a fast, flexible solution to traditional testing methods.

Detectable elements to concentrations of 100% are: Aluminum, Antimony, Barium, Cadmium, Calcium, Chlorine, Chromium, Copper, Iron, Manganese, Molybdenum, Nickel, Phosphorous, Potassium, Silicon, Silver, Sulfur, Tin, Titanium, Vanadium, and Zinc.

*Available in the Americas. For additional information, please contact us.

Segment: Scientific
Manufacturing Company: Olympus Innov-X

The X-5000 integrates advanced 3-beam (kV-mA-filter) technology with a silver anode X-ray tube and large area Silicon Drift Detector (SDD). This powerful EDXRF combination is optimized to analyze 20+ elements in oils along with providing the highest possible sensitivity for sulfur. Analyzers are pre-calibrated with NIST standards in a clean mineral oil matrix without interfering elements.

A sample guide/holder is attached to the X-5000 sample deck to accurately and securely place sample cups or bottles with a secondary spill containment for liquid samples. Users can analyze samples easily using default settings. Calibrations can be adjusted accordingly for applications that require custom standards for control over elemental correlation.

Use it around the work site, at the inspection station, on the production line, or on the lab bench. This self-contained, closed-beam unit provides the ultimate in user safety. The optional three-hour Li-ion battery pack provides true field use capablity. Weighing only 20lbs, the X-5000 can go where it is needed.

PrincipleEnergy Dispersive X-ray Fluorescence
SamplePetroleum and water based
ElementsAluminum, Antimony, Barium, Cadmium, Calcium, Chlorine, Chromium, Copper, Iron, Manganses, Molybedenum, Nickel, Phosphorous, Ptassium, Silicon, Silver, Sulfur, Tin, Titanium, Vanadium and Zinc.
Detection RangeLow PPM to 100%
Repeatability0.0015 wt%
CalibrationFactory calibrated or user defined with 1 point minimum
Sample Requirement10 mL liquid and 1 mg solid
Measurement TimeUser programmable up to 360 seconds
External OutputUSB, RS-232, 9 in Serial, Ethernet, and 15 pin monitor
Power100-240V AC, 50/60 Hz
Battery3 hour Li-ion optional battery pack
Dimensions12" x 13" x 8" in / 30 x 33 x 20 cm
Sample Chamber12" x 8" x 5" in / 30 x 20 x 12 cm
Weight25 lbs/11.5 Kg

제품 문의

HORIBA제품의 자세한 정보를 원하시면, 아래의 양식에 내용을 입력을 부탁드립니다.

* 는 필수입력항목입니다.

Related products

51 series
51 series

방폭형 가스 분석기

Process
Process

Process Analyzer System

SLFA-6000
SLFA-6000

X선 형광 유황 분석기

LO-300
LO-300

레이저 스캔 오일 필름 검출기

MESA-7220V2
MESA-7220V2

X선 형광 유중의 황/염소 분석기

OCMA-500
OCMA-500

폐수 오일 측정기

OCMA-550
OCMA-550

오일 농도 측정기

SLFA-60
SLFA-60

X선 형광 유황 분석기

SLFA-6000
SLFA-6000

X선 형광 유황 분석기

MESA-50
MESA-50

X선 형광 분석기

MESA-50K
MESA-50K

X선 형광 분석기

MESA-7220V2
MESA-7220V2

X선 형광 유중의 황/염소 분석기

PX-375
PX-375

PM & 중금속 분석기

SLFA-60
SLFA-60

X선 형광 유황 분석기

SLFA-6000
SLFA-6000

X선 형광 유황 분석기

XGT-9000
XGT-9000

X선 분석 현미경(Micro-XRF)

XGT-9000SL
XGT-9000SL

X선 분석 현미경 초대형 챔버 모델