SLFA-2100/2800

X-ray Fluorescence Sulfur-in-Oil Analyzers

The SLFA-2100/2800 are designed specifically to meet the recent demanding needs of measuring the new low sulfur fuels, diesel and RFG.

Using the X-ray fluorescence technique, fast and accurate measurements can be carried out in compliance with the ASTM D4294 method, either in the lab or in the field.

A detection limit of 5 ppm sulfur takes you to new realms of measurement sensitivity. HORIBA's high sensitivity analyzer makes quick, accurate measurements of petroleum fuel samples from very low to high sulfur concentrations - i.e., all the way from gasoline to heavy fuel oils. A large, easy-to-read LCD screen, simple function keys, alphanumeric keypad and other features make the SLFA-2100/2800 Series so easy to use.

The SLFA-2800 has an automated turntable to measure up to eight samples unattended, while the SLFA-2100 is a single-sample version.

Segment: Scientific
Firma produkcyjna : HORIBA Scientific
  • Wide measurement range (0-9.999%) is acceptable for very small content as in diesel oil or high sulfur content as in heavy oil.
  • Calibration graphs have been extended and the analyzer selects automatically out of seven scales (0.002/0.01/0.05/…/10%).
  • High precision measurement (Repeatability: 1.6 ppm, Lower detection limit: 5 ppm) Due to the miniature X-ray tube, extremely precise results can be achieved without purging of He or another gas and this system also include a correction function for temperature and atmospheric pressure without He purge.
  • SLFA-2800 is equipped with a turntable, which makes sequential measuring of up to eight samples.
  • Standards applied to device measurement functions: JIS K2541, JIS B7995 (Japan), ASTM D4294 (USA), ISO 8754
PrincipleX-ray fluorescent analysis
Sample

Sulfur content in petroleum products, such as heavy oil, naphtha, crude oil, etc.

ElementSulfur
Range0 - 9,999%
Detection Limit5 ppm or less
AccuracyLess than 5 ppm (with a sample containing 1% sulfur)
Less than 1.6 ppm (with a sample containing 0% sulfur)
CalibrationCalibration made using any standard sample (2 to 20 calibration points)
Sample requirement4-10 ml
Measurement timeUser set from 10 to 600 seconds
External outputPrintout of results and digital data output (RS-232C interface)
Power supply100 V AC to 240 V±10%, 50/60 Hz
Power comsumptions150 VA
MassApprox 21kg (SLFA-2100), 24kg (SLFA-2800)
Dimensions430 (W) x 500 (D) x 230 (H) mm
19,9 (W) x 19,7 (D) x 9,1 (H) in
Standards applied to device measurement functions

JIS K2541, JIS B7995 (Japan), ASTM D4294 (USA), ISO 8754

Schematics

Wniosek o udzielenie informacji

Masz pytania lub prośby? Skorzystaj z tego formularza, aby skontaktować się z naszymi specjalistami.

* Te pola są obowiązkowe.

Related products

MESA-7220V2
MESA-7220V2

X-ray Fluorescence Sulfur/Chlorine-in-oil Analyzer

SLFA-20
SLFA-20

X-ray Fluorescence Sulfur-in-Oil Analyzer

SLFA-60
SLFA-60

X-ray Fluorescence Sulfur-in-Oil Analyzer

SLFA-6000
SLFA-6000

X-ray Fluorescence Sulfur-in-Oil Analyzer

X-5000*
X-5000*

Energy Dispersive X-ray Fluorescence Analyzer

XPLORER-NS*
XPLORER-NS*

Total Nitrogen and Sulfur Analyzer

XPLORER-TX/TS*
XPLORER-TX/TS*

Total Halogen and Sulfur Analyzer

XPLORER-V*
XPLORER-V*

Next Generation Total Nitrogen and Total Sulfur Analyzer

MESA-50
MESA-50

X-Ray Fluorescence Analyzer

MESA-50K
MESA-50K

X-Ray Fluorescence Analyzer

MESA-7220V2
MESA-7220V2

X-ray Fluorescence Sulfur/Chlorine-in-oil Analyzer

SLFA-20
SLFA-20

X-ray Fluorescence Sulfur-in-Oil Analyzer

SLFA-60
SLFA-60

X-ray Fluorescence Sulfur-in-Oil Analyzer

SLFA-6000
SLFA-6000

X-ray Fluorescence Sulfur-in-Oil Analyzer

X-5000*
X-5000*

Energy Dispersive X-ray Fluorescence Analyzer

XGT-9000
XGT-9000

X-ray Analytical Microscope (Micro-XRF)

XGT-9000SL
XGT-9000SL

X-ray Analytical Microscope
with a Super Large Chamber

Corporate