| Product name | ORP meter |
|---|
| Model | HO-200 |
|---|
| Combined sensor | ORP electrode |
|---|
| Measurable range | ORP | −2000 mV to 2000 mV (display range: −2200 mV to 2200 mV) |
|---|
| Temperature | 0℃ to 100℃ - Display range (the sensor types are detected automatically):
−10℃ to 110℃ - Display range (the sensor types are input by manually):
−20℃ to 130℃
|
Display resolution | ORP | 1mV |
|---|
| Temperature | 0.1℃ |
| Performance | ORP | Repeatability | Within ±5mV (response for equivalent input) |
|---|
| Linearity | Within ±5mV (response for equivalent input) |
| Temperature | Repeatability | ±0.3℃ (response for equivalent input) |
| Linearity | ±0.3℃ (response for equivalent input) |
Transmission output | Number of output point | 2 (the negative terminals for transmission outputs are internally connected at the same electric potential) |
|---|
| Output type | 4 mA to 20 mA DC: input/output insulation type |
| Load resistance | Max: 900Ω |
| Linearity | Within ±8 mA (output only) |
| Repeatability | Within ±0.02 mA (output only) |
| Output range | Output 1 | ORP: Selection from preset ranges or free range setting within measuring range. |
| Output 2 | Temperature: Free setting within a range between −20℃ and 130℃ |
| Occasional out for error | Hold or burnout to either 3.8 mA or 21 mA |
| Transmission hold | Selectable from transmission signal is held at the latest value or preset value. |
| Contact output | Number of output | 3 |
|---|
| Output type | No-voltage contact output |
| Contact type | Relay contact; SPDT (1c) |
| Contact capacity | 250 V AC 3 A, 30 V DC 3 A (resistance load) |
Contact function | R1, R2 | Selectable from upper limit alarm, lower limit alarm, ON/OFF control, currently holding of transmission output, and cleaning output (the contact is closed during alarm operation, opened normally and while the power is down). |
| FAIL | Error alarm (Closed in the normal state, opened in the failure state or while the power is down). |
| Alarm setting | - Setting range: −2000 mV to 2000 mV
- Delay time: 0 seconds to 600 seconds
|
| Control setting | - Setting range: −2000 mV to 2000 mV
- Control width: 2 mV to 400 mV (±1 mV to ±200 mV)
|
| Cleaning output | Number of output points | 1 |
|---|
| Output type | Contact output with voltage (output of connected power supply voltage) |
| Contact type | Relay contact, SPST (1a) |
| Contact capacity | 250 V AC 0.5 A |
| External instrument | Solenoid valve for cleaning control |
| Settings | Cleaning period | 0.1 hours to 168.0 hours |
| Cleaning time | 2 seconds to 600 seconds |
| Hold time | 2 seconds to 600 seconds |
| Timer accuracy | Within 2 minutes per month |
Description of cleaning operation | One of the following operations. - Operation of internal timer only
- Operation of internal timer and external input command
- Enable the internal timer only when external input is active.
- The cleaning trigger signal (the external trigger signal must be longer than 2 seconds).
|
| Contact input | Number of input points | 1 |
|---|
| Contact type | No-voltage "a" contact for open collector |
| Conditions | ON resistance: 100 Ω max. Open voltage: 24 V DC Short-circuit voltage: 12 mA DC max. |
| Contact function | External input for cleaning |
Communication function | Communication type | RS-485 |
|---|
| Signal type | 2 wires system, isolated from the input circuit (not isolated from transmission circuit) |
Temperature measurement | Applicable temperature element | Platinum resistor: 1 kΩ (0℃) |
|---|
Positive relation resistor with temperature: 500 Ω (25℃), 6.8 kΩ (25℃), 10 kΩ (25℃) |
| Element selection method | Automatic temperature sensor type detection or manual selection (no temperature element is selectable) |
| Calibration | ORP adjust function | Adjust (offset adjustment): −200 mV to 200 mV Span sensitivity correction: 0.500 to 1.500 |
|---|
| Temperature calibration | 1 point calibration comparing reference thermometer |
| Self-check | Electrode diagnostic error | Reference electrode impedance error (only applicable for differential circuit mode with a liquid contact electrode), temperature sensor short-circuit, temperature sensor disconnection, and out of the temperature measurement range |
|---|
| Converter error | CPU, ADC, and EEPROM errors |
| Operating temperature range | −20℃ to 55℃ (without freeze) |
|---|
| Operating humidity range | Relative humidity: 5% to 90% (without condensation) |
|---|
| Storage temperature | −25℃ to 65℃ |
|---|
| Power supply | Rated power supply voltage | 100 V to 240 V AC ±10% 50/60 Hz |
|---|
| Power consumption | MAX. 15 VA |
| Others | With power switch for maintenance use |
Compatible standards | CE marking | EMC :EN61326-1 Class A, Industrial electromagnetic environment Safety :EN61010-1 RoHS :EN50581 9. Industrial monitoring and control instruments |
|---|
| FCC rules | Part15 Class A |
| Structure | Installation | Outdoor installation type |
|---|
| Installation method | Mount on 50 A pole or wall |
| Protection code | IP65 | IEC60529, JIS C0920 |
| Case material | Aluminum alloy (coated with epoxy-denatured melamine resin) |
| Material of fittings | SUS304 |
| Material of hood | SUS304 (coated with epoxy-denatured melamine resin) |
| Material of window | Polycarbonate |
| Display element | Reflective monochrome LCD |
| External dimensions | 180 (W) mm × 155 (H) mm × 115 (D) mm (excluding mounting brackets) |
|---|
| Mass | Main body: approx. 3.5 kg, Hood and fittings: approx. 1 kg |
|---|