MEXA-ONE

Motor Exhaust Gas Analyzer

HORIBA Awarded “2012 Hardware Innovation of the Year Award” for MEXA-ONE Design

_________________________________________________

Reliable・Efficient・Expandable

MEXA-ONE offers an intuitive user interface with a highly efficient hardware and software design.
This results in increased testing efficiency and economical facility operation, while enhancing reliability and accuracy. These advancements are possible because the MEXA-ONE software employs new "HORIBA ONE PLATFORM". This platform integrates the test devices in an emission cell into a single user interface, increasing efficiency and optimizing user control over the entire testing process.

事業部: Automotive
製造商: HORIBA, Ltd.

 Increased Test Efficiency

MEXA-ONE incorporates HORIBA's leading-edge technology to enhance reliability and performance beyond today's expectations.
Improved durability and maintenance assure efficient test facility operation, reducing overall test duration and accelerating engine and vehicle development.

Faster Response and Shorter Test Times

Fully automated, customer-defined, pre-test routines ensure system readiness for testing. Overall test duration is minimized by reducing analyzer response and wait times between measurements.

  • 50% reduction in analyzer response times (t99) *
  • 30% reduction in analyzer calibration waiting times *
  • Optimization of analyzer purging times

* By comparison with HORIBA's conventional products

Lower Cost of Ownership

Savings are realized through reduced operational costs, with a focus on reduction of consumables and facility requirements.

  • 10% reduction in power consumption *
  • Filter element replacement is eliminated due to the use of the automatic purge function for the back flushing filter
  • 30% reduction in analyzer calibration gas consumption *

* By comparison with HORIBA's conventional products

Reduction in Consumables

Example
For a 12 hours per day operation and total of 200 days per year, the following savings in running cost can be achieved.
(This example is based on 10 systems)

Based on the condition of ;
・Calibration / zero and span check conducted every 2 hours
・Leak check conducted every 8 hours
・Filter element replaced every 4 hours

 Improved Test Facility Operation

Enhanced Maintenance Support

Ensuring Accurate Measurement

Automatic notifications of periodic inspections and adjustments are generated as required by emission regulations in accordance with a user-defined schedule. Inspections and adjustments can also be started from the control window.


                                                              QC Sequence

Preventative Maintenance Feature

This automatic function provides advanced notification for the replacement of consumable parts. This process enables proactive maintenance to be performed.

MEXA-ONE automatically monitors analyzer sensitivity and displays the request for readjustment before exceeding the permissible range.


                                                       Sensor Sensitivity Monitor

Effective Troubleshooting

When an alarm occurs, the MEXA-ONE not only displays details of the alarm but also generates a display with troubleshooting instructions. Quick alarm resolution enables effective testing.


Troubleshooting (Alarm Detail)

High Performance and Durability

MEXA-ONE exceeds the durability seen in about 4,500 MEXA-7000 units in operation around the world. For example, the entire sample handling system has undergone a major upgrade to optimize sample flow and to reduce pump load.

 Wide Application Range

Evaluation of NOx After-Treatment Catalyst Systems

Measurement of nitrogen compounds (NO, NO2, N2O, NH3) is essential for evaluation of NOx after-treatment systems. MEXA-ONE can be easily configured to provide optimum measurement capability based on the testing objective.

Close-Coupled Transient EGR Measurement

To deliver faster response and more accurate EGR measurement, MEXA-ONE incorporates new EGR sample handling and analysis in a compact cabinet.

Multi-point EGR Measurement

・Multi-point measurement can now be performed on complete EGR systems using MEXA-ONE's modular design.

HCHO/N2O Measurement

Overwhelmingly low-noise and high-accuracy Formaldehyde and N2O measurement in the low concentration range is realized by HORIBA's next generation infrared gas analysis technology IRLAMTM.

* IRLAM is a registered trademark or trademark of HORIBA, Ltd. in Japan and other countries


Click here for more information about IRLAM

Example of measurement results of formaldehyde (HCHO) in a vehicle exhaust gas test

MEXA-ONE System Line-up

MEXA-ONE is a flexible system allowing configuration for a wide range of applications.


※1 Oven is equipped with heated analyzers and Heated Sample-Handling System
※2 Analyzer for CO2 low measurement (AIA-22) is available
※3 Optional unit (HSPS-0X) is required
※4 Heated Filter with back flush purge is recommended

OPTION / FUNCTION

・Remote EGR (R-EGR-01)
・Remote EGR (R-EGR-02H)
・Remote Tracer (R-TR-01)

・Heated Filter with back flush purge (dual type) (F-02HB)
・Heated Filter with back flush purge (F-01HB)
・Heated Filter (F-01H)

・Span Gas Selector (SGS)
・Remote Multi Gas Controller (MGC-0XM)

・Gas Divider and Converter Checker Unit (high accurate type) (GDC-ONE)
・Gas Divider and Converter Checker Unit (GDC-703)
・Gas Divider and Converter Checker Unit (base model type) (GDC-Lite)
・Leak Checker (LCK-01)
・Heated Bubbler (HCU-700)

Standard

Measurement 
component
Model Analyzer unit Principle※1 Range※2
CO AIA-11 Half 19 Inch NDIR 0-50 ~ 0-5000 ppm
CO AIA-31 Half 19 Inch NDIR 0-0.5 ~ 0-12 vol%
CO AlA-41 Half 19 Inch NDIR 0-3 ~ 0-20 vol%
CO2 AlA-22 Half 19 Inch NDIR 0-0.1 ~ 0-6 vol%
CO2 AlA-32 Half 19 Inch NDIR 0-0.5 ~ 0-20 vol%
CO2 AlA-42 Half 19 Inch NDIR 0-3 ~ 0-20 vol%
HC AlA-14 Half 19 Inch NDIR 0-100 ~ 0-5000 ppm
HC AlA-34 Half 19 Inch NDIR 0-5000 ~ 0-10000 ppm
N2O AlA-15 Half 19 Inch NDIR 0-100 ~ 0-5000 ppm
O2 MPA-01 Half 19 Inch MPD 0-1 ~ 0-25 vol%
THC FIA-01 Half 19 Inch FID 0-10 ~ 0-20000 ppmC
NO/NOx CLA-01 Half 19 Inch CLD 0-10 ~ 0-10000 ppm
CH4 GFA-01 Half 19 Inch GC-FID 0-10 ~ 0-3000 ppm
THC FIA-01H 19 Inch Heated-FID 0-10 ~ 0-60000 ppmC
THC,CH4,NMHC FIA-02H-NC 19 Inch

Heated-FID
NMC-FID

THC 0-10 ~ 0-5000 ppmC
CH4 0-10 ~ 0-5000 ppm
NMHC is measured by dual detector
THC,CH4,NMHC FIA-02H-ND 19 Inch Heated-FID
NMC-FID
THC 0-50 ~ 0-60000 ppmC
CH4 0-50 ~ 0-25000 ppm
NMHC is measured by dual detector
NO/NOx CLA-01HV 19 Inch Heated-CLD 0-10 ~ 0-10000 ppm
NO,NOx,No2 CLA-02HV 19 Inch Dual Heated-CLD NO 0-10 ~ 0-10000 ppm
NOx 0-10 ~ 0-10000 ppm
NO2 is measured by dual detector
THC FIA-01O OVN Heated-FID 0-10 ~ 0-60000 ppmC
THC,CH4,NMHC FIA-02O-NC OVN Heated-FID
NMC-FID
THC 0-10 ~ 0-5000 ppmC
CH4 0-10 ~ 0-5000 ppm
NMHC is measured by dual detector
THC,CH4,NMHC FIA-02O-ND OVN Heated-FID
NMC-FID
THC 0-50 ~ 0-60000 ppmC
CH4 0-50 ~ 0-25000 ppm
NMHC is measured by dual detector
NO/NOx CLA-01OV-2 OVN Heated-CLD 0-10 ~ 0-10000 ppm
NO,NOx CLA-02OV-3 OVN Dual heated-CLD NO 0-10 ~ 0-10000 ppm
NOx 0-10 ~ 0-10000 ppm
NO2 is measured by dual detector
HCHO XLA-13H 19 Inch QCL-IR 0-20~100 ppm

Low Emission Measurement

Measurement 
component
Model Analyzer unit Principle※1 Range※2
CO AIA-11SL 19 Inch NDIR 0-10 ~ 0-1000 ppm
CO2 AIA-22 Half 19 Inch NDIR 0-0.1 ~ 0-6 vol%
THC FIA-01SL Half 19 Inch FID 0-1 ~ 0-500 ppmC
NO/NOx CLA-01SL Half 19 Inch CLD 0-1 ~ 0-500 ppm
CH4 GFA-01SL Half 19 Inch GC-FID 0-1 ~ 0-500 ppm
N2O XLA-11 Half 19 Inch QCL-IR 0-0.5 ~ 0-20 ppm

Remote Type (Option)

Measurement 
component
Model Analyzer unit Principle※1 Range※2
CO2 R-EGR-01 Remote NDIR Dry 1Line 0-10 ~ 0-20 vol%
CO2 R-TR-01 Remote NDIR Dry 1Line 0-10 ~ 0-20 vol%
CO2 R-EGR-02H Remote NDIR Wet 2Line 0-10 ~ 0-20 vol%

※1
NDIR : Non Dispersive Infrared Detector
FID : Flame Ionization Detector
GC-FID : Flame lonization Detector with Gas Chromatography
NMC-FID : Flame lonization Detector with Non Methane Cutter
CLD : Chemiluminescence Detector
CLD[Wet/Dry] : Chemiluminescence Detector [Wet/Dry switchable]
MPD : Magnetopneumatic Detector
QCL-IR: Quantum Cascade Laser Infrared Detector

※2 Other ranges on request

System Specifications

  • Dimension
    -Standard 19 inch Rack・・・655(W) × 855(D) × 1970(H) mm
    -Oven Type Heated Analyzer・・・430(W) × 550(D) × 1100(H) mm
  • Mass・・・Depends on system (e.g. MEXA-ONE–D1(OVN-type) = Approx. 350 kg)
  • Ambient temperature・・・5 deg.C to 40 deg.C
  • Ambient humidity・・・80% or less as relative humidity
  • Ambient Pressure・・・80 kPa to 102 kPa (abs)
    (Altitude below 2000 m above sea-level)
RDE tests on the chassis dynamometer
RDE tests on the chassis dynamometer
Catalyst testing in automobiles and components
Catalyst testing in automobiles and components
Engine testing in automobiles and components
Engine testing in automobiles and components
Measuring vehicle emissions on a chassis dynamometer
Measuring vehicle emissions on a chassis dynamometer
To comply with newest emission legislation it is necessary to test vehicle emissions on chassis dynamometer with the corresponding driving cycles.
Particle Measurement in the Sub-23nm Range
Particle Measurement in the Sub-23nm Range
Concerns exist that advances in modern engine technology may contribute to large portions of solid particles at sizes smaller than 23nm. The EU Joint Research Center has confirmed this concern in several investigations.

留言諮詢

如您有任何疑問,请在此留下詳細需求或問題,我們將竭誠您服務。

* 這些欄位為必填項目。

Related products

CVS-ONE
CVS-ONE

Constant Volume Sampler

EXFM-ONE
EXFM-ONE

Ultrasonic Exhaust Flow Meter

FTX-ONE-CL
FTX-ONE-CL

FTIR Exhaust Gas Analyzer Dilute Measurement Type

FTX-ONE-CS/RS
FTX-ONE-CS/RS

FTIR Exhaust Gas Analyzer Direct Measurement Type

MDLT-ONE
MDLT-ONE

Micro Dilution Tunnel

MEDAS
MEDAS

Dynamic Altitude Simulation

MEDAS Humidity Module
MEDAS Humidity Module

Altitude Simulator

MEDAS Temperature Module
MEDAS Temperature Module

Altitude Simulation

MEXA-1170HCLD
MEXA-1170HCLD

Heated Type NOx Analyzer

MEXA-1170HFID
MEXA-1170HFID

Heated Type THC Analyzer

MEXA-1170SX
MEXA-1170SX

Motor Exhaust Gas Sulfur Analyzer

MEXA-1300R
MEXA-1300R

Motor Exhaust Gas Analyzer

MEXA-2000SPCS series
MEXA-2000SPCS series

Solid Particle Counting System

MEXA-584L
MEXA-584L

Automotive Emission Analyzer

MEXA-730λ
MEXA-730λ

Air-to-fuel Ratio Analyzer

MEXA-ONE-FT
MEXA-ONE-FT

FTIR Motor Exhaust Gas Analyzer

MEXA-ONE-QL-NX
MEXA-ONE-QL-NX

Laser Spectroscopic Motor Exhaust Gas Analyzer

OBS-ONE GS Unit
OBS-ONE GS Unit

On-board Emissions Measurement System

OBS-ONE PM unit
OBS-ONE PM unit

On-board Emissions Measurement System

OBS-ONE PN Unit
OBS-ONE PN Unit

On-board Emissions Measurement System

OBS-ONE SPN10 Unit
OBS-ONE SPN10 Unit

On-board SPN10 measurement for real-world

OBS-ONE-XL (IRLAM)
OBS-ONE-XL (IRLAM)

On-board NH3/N2O Measurement System for real-world driving

PFS-ONE
PFS-ONE

Particulate Filter Management System

PTFM-1000V2
PTFM-1000V2

Pitot Tube Exhaust Flow Meter

PTFM-ONE-DT
PTFM-ONE-DT

Dual Pitot Tube Exhaust Flow Meter

Torque Matching
Torque Matching

Road-to-Rig Chassis Dyno Replication

FTX-ONE-CL
FTX-ONE-CL

FTIR Exhaust Gas Analyzer Dilute Measurement Type

FTX-ONE-CS/RS
FTX-ONE-CS/RS

FTIR Exhaust Gas Analyzer Direct Measurement Type

IR-300
IR-300

Vapor Concentration Monitor

IR-400
IR-400

High-grade type Gas Monitor for Chamber Cleaning End Point Monitoring

MEXA-1170HCLD
MEXA-1170HCLD

Heated Type NOx Analyzer

MEXA-1170HFID
MEXA-1170HFID

Heated Type THC Analyzer

MEXA-1170SX
MEXA-1170SX

Motor Exhaust Gas Sulfur Analyzer

MEXA-1300R
MEXA-1300R

Motor Exhaust Gas Analyzer

MEXA-584L
MEXA-584L

Automotive Emission Analyzer

MEXA-ONE-FT
MEXA-ONE-FT

FTIR Motor Exhaust Gas Analyzer

MEXA-ONE-QL-NX
MEXA-ONE-QL-NX

Laser Spectroscopic Motor Exhaust Gas Analyzer

OBS-ONE GS Unit
OBS-ONE GS Unit

On-board Emissions Measurement System

OBS-ONE-XL (IRLAM)
OBS-ONE-XL (IRLAM)

On-board NH3/N2O Measurement System for real-world driving

AP-380 Series
AP-380 Series

Air Quality Monitor

EMGA-921
EMGA-921

Hydrogen Analyzer

EMGA-Expert
EMGA-Expert

Oxygen/Nitrogen/Hydrogen Analyzer
(Flagship High-Accuracy Model)

EMGA-Pro
EMGA-Pro

Oxygen/Nitrogen Analyzer (Entry Model)

EMIA-Expert
EMIA-Expert

Carbon/Sulfur Analyzer
(Flagship High-Accuracy Model)

EMIA-Pro
EMIA-Pro

Carbon/Sulfur Analyzer (Entry Model)

EMIA-Step
EMIA-Step

Carbon/Sulfur Analyzer (Tubular Electric Resistance Heating Furnace Model)

ENDA-7000 Series
ENDA-7000 Series

Stack Gas Analyzer

IR-300
IR-300

Vapor Concentration Monitor

IR-400
IR-400

High-grade type Gas Monitor for Chamber Cleaning End Point Monitoring

MEXA-1170HCLD
MEXA-1170HCLD

Heated Type NOx Analyzer

MEXA-1300R
MEXA-1300R

Motor Exhaust Gas Analyzer

MEXA-584L
MEXA-584L

Automotive Emission Analyzer

OBS-ONE GS Unit
OBS-ONE GS Unit

On-board Emissions Measurement System

OBS-ONE-XL (IRLAM)
OBS-ONE-XL (IRLAM)

On-board NH3/N2O Measurement System for real-world driving

TCA-5000
TCA-5000

Hydrogen Gas Analyzer

Corporate