CCEVA

Carbon Capture Evaluation System

For the development of CO2 solid adsorption materials, separation membrane materials, and CO2 separation and recovery modules.

To achieve carbon neutrality by 2050, extensive research and development are underway on carbon dioxide (CO2) adsorption materials and their evaluation systems. In the field of CO2 adsorption and separation materials R&D, various separation and recovery methods are employed depending on the source and concentration of CO2.
It is essential to evaluate the performance and durability of these adsorption materials accordingly.

產品分類: Process Gas
製造商: HORIBA, Ltd.

Features of the system

  • A single device can generate gas at any desired concentration, control various test conditions, and analyze the gas after adsorption and desorption.
  • Supports evaluation using real exhaust gas (optional).
  • Various test sequences can be performed automatically, enabling continuous 24-hour testing.
  • Equipped with standard safety functions, including abnormality detection and emergency stop switches.

 

HORIBA’s Solution

Carbon Capture Evaluation System is the solution supporting customers who moves from basic research to demonstration phase of CO2 capture.

  • Enables testing with pressure control
  • Allows testing with a flow rate of several liters per minute
  • Supports long-term continuous testing, such as adsorption/desorption cycle and durability tests
  • Provides evaluation test system in a single package
  • Facilitates highly reproducible automated testing

 

CO2 Adsorption / Desorption Evaluation Test Example

Image of Gas Flow

Ex. Measurement Data

 

Carbon Capture Evaluation System CCEVA

 Analyzer

Up to 3 components incl. CO2 (optional)
<Ex. Specification of CO2 Analyzer>

  •  CO2: 0 - 100 / 1000 ppm (low conc.)
  •  CO2: 0 - 10 / 25 / 100 vol% (high conc.)
    *Both ranges are included

Number of flow path

1

Flow rate range

0.2 to 1 L/min

Pressure range

-70 to +700 kPaG

Chiller temperature control range

-20 to +150℃*

Reactor tube dimensions

To be decided by meeting

Mass flow controller

2 to 3 units (Nor Air, CO2)

Humidification

Optional

Injected gas

Up to 3 components (Optional)

*The chiller’s temperature control range may vary depending on the heat transfer liquid

 

Dimensions (Unit:mm)

*Appearance and dimensions may vary depending on the specifications.

Carbon Capture and Utilization
Carbon Capture and Utilization

留言諮詢

如您有任何疑問,请在此留下詳細需求或問題,我們將竭誠您服務。

* 這些欄位為必填項目。

更多推荐

AP-380 Series
AP-380 Series

Air Quality Monitor

BE-150
BE-150

OEM gas (CO/HC) analyzer

BE-220FSD
BE-220FSD

OEM gas (NO) analyzer

EMGA-Expert (EMGA-21E)
EMGA-Expert (EMGA-21E)

Hydrogen Analyzer EMGA Series
(Flagship High-Accuracy Model)

EMGA-Expert (EMGA-30E/20E)
EMGA-Expert (EMGA-30E/20E)

Oxygen/Nitrogen/Hydrogen Analyzer
(Flagship High-Accuracy Model)

EMGA-Pro (EMGA-20P)
EMGA-Pro (EMGA-20P)

Oxygen/Nitrogen Analyzer (Entry Model)

EMIA-Expert
EMIA-Expert

Carbon/Sulfur Analyzer
(Flagship High-Accuracy Model)

EMIA-Pro
EMIA-Pro

Carbon/Sulfur Analyzer (Entry Model)

EMIA-Step
EMIA-Step

Carbon/Sulfur Analyzer (Tubular Electric Resistance Heating Furnace Model)

ENDA-7000 Series
ENDA-7000 Series

Stack Gas Analyzer

IR-300 Series
IR-300 Series

Vapor Concentration Monitor

IR-400 Series
IR-400 Series

High-grade type Gas Monitor for Chamber Cleaning End Point Monitoring

MEXA-1300R
MEXA-1300R

Motor Exhaust Gas Analyzer

MEXA-584L
MEXA-584L

Automotive Emission Analyzer

OBS-ONE GS Unit
OBS-ONE GS Unit

On-board Emissions Measurement System

OBS-ONE-XL (IRLAM)
OBS-ONE-XL (IRLAM)

On-board NH3/N2O Measurement System for real-world driving

TCA-5000
TCA-5000

Hydrogen Gas Analyzer