VS100 HTR

VS100 HTR product picture

Compact High Throughput & Resolution Spectrometer for OEM Industry

Discover the New VS100 HTR Spectrometer—where sensitivity & precision meet versatility.

Engineered for combined excellent throughput and resolution, VS100 HTR Spectrometer delivers up to five times the sensitivity of standard systems with minimal stray light.
Its robust, easily integrated design, ensures superior mechanical strength and temperature stability, guaranteeing reliable results in both industrial and laboratory environments.

Specially optimized for low-intensity signal detection, the VS100 HTR provides uncompromising sensitivity and accuracy requested for absorbance or emission measurements in Lifesciences or semiconductor applications.

Customizable in single or multichannel use, it’s the ideal solution for advanced analytical applications.

This product is available for EMEA and Asian markets.
If you need this reference for other regions, please scroll down and contact us.

Segmento: Scientific
Fabricante: HORIBA France SAS

Key Features

  • High throughput & resolution
  • Large spectral range
  • Single or multichannel design available
  • Robustness and Thermal stability
  • Easy integration for industrial process environments

Key Applications

  • Analytical instrumentation integrators
  • Microplate reader, High Performance Liquid chromatography
  • Spectroscopy instrumentation
  • Semiconductors End point detection
Specifications
Typical applicationLifesciences (Microplate readers, HPLC techniques,...), Semiconductors (Endpoint)
Measurement typeAbsorbance, Emission, Reflectance
Spectral range190-900 nm
Spectral resolution (FWHM)1 nm(1)
Numerical aperture (NA)0.22
Relative stray light<0.15%(2)
Wavelength interpolation accuracy<0.1 nm(3)
Wavelength stability over operational temperature<0.2 nm
DetectorBack-thinned CCD
Maximum acquisition rate714 Spectra/s
Output signal format16bit
Dynamic range (FW/RN)5200:1(4)
SNR500(5)
Input connectorSMA 905(6)
Recommended input fiber core diameter600 µm(7)
Recommended fiber NA0.22
CommunicationEthernet TC/IP, Programmable Digital & Analog IO
Power requirements24V, 1A
Typical power consumption4W
SoftwareSDK SAPI / JY70 Spectrometer
  
Operating temperature5°C to 45°C
Storage temperature5°C to 55°C
Dimensions (L, W, H)170 x 142 x 135 mm

(1) 25 µm slit
(2) Measured with GG495 UV cut filter and 2,800 K tungsten lamp. Relative stray light is the maximum relative output for wavelength smaller than 480 nm. It is expressed in % relative to the maximum signal output in the 800 mm region.
(3) Wavelength interpolation accuracy measured after factory calibration on spectral lines.
(4) Dynamic range is defined as the ratio of the saturation level to the readout noise of the sensor.
(5) SNR is defined as the ratio of the average signal value over time to the standard deviation of the signal.
(6) Customization on slits, fibers and detectors available for volume industrial applications.
(7) 600 µm fiber core diameter used for test. Other diameters are possible.

Pedido de Informação

Você tem alguma dúvida ou solicitação? Utilize este formulário para entrar em contato com nossos especialistas.

* Esses campos são obrigatórios.

Corporate