ASGU-370TS SPLIT

Automatic Span Gas Generator Unit for Quality control at field test

The portable one component multipoint calibration system ASGU-370TS is designed for checking of gas analyzers. The main application is for the ongoing quality control in field.
The portable calibration unit ASGU-370TS will be used for the dynamic and continual manufacture of zero and span gas to perform all ongoing quality control procedures according valid EN Norms. To produce span gas the unit uses technologies like dilution, permeation, Gas Phase Titration.

In the case of the ASGU-370TS SPLIT version, the technology is divided into 2 cases (stackable for transport) in order to achieve a back-friendly wearing comfort: upright posture when carrying, Symmetrical body strain, Load closer to the body.

Oddělení: Ambient
Výrobní společnost: HORIBA (Austria) GmbH
Base product: ASGU-370 series
  • Portable one component multipoint calibration system acc. EN 14211 or EN 14212 or EN 14626
  • High accuracy of span gas in cause of usage of factory calibrated digital thermal mass flow controllers in high quality
  • Comfortable operation via big, illuminated Touch-Screen-Display
  • Operation via RS232 and Ethernet interface (Bayern Hessen protocol)
  • Delivery scope includes remote software for easy external handling (Ethernet)
  • High flexibility by free definable span points (up to 20)
  • High flexibility by free definable cycles (e.g., Lack of fit)
  • High flexibility by free definable sequences (stringing cycles together)
  • Programmable timer allows time shifted start of calibration process
  • Internal data logger (option) stores raw values from calibration procedure (set value and actual value, status) for reporting with evaluation software (included in scope of delivery)

Principle

Dilution (incl. built in cylinder), Permeation, Gas Phase Titration, (Mixed gas dilution) 

Application

Quality control in Laboratory
Quality control in field                                                                                

Stage of extension

Only one channel (module) per unit

Flow regulation

Digital Mass Flow Controllers

Span gas repeatability

+/- 1%

Span gas linearity

+/- 2% (minimum flow > 20% full scale)

Permeation System (NO2, SO2, NH3, H2S, BTX)

PID temperature controller with Pt 100 sensor
Temperature: 50 °C
Accuracy ± 0,1 °C
Indication of actual temperature on display

Zero Air Supply

Internal Zero gas preparation

Operation

Manual (Touch Screen Display)
External via RS232 (Bayern Hessen protocol)
External vie Ethernet (Remote Software or Bayern Hessen protocol)

Battery pack

For uninterruptible power supply for approx. 30 min. purge mode without mains voltage

Power

230 V / 50Hz
Power consumption depends on channel

Case 1
(Span Gas Generator)

Span Gas Source (Span Gas Cylinder or Permeation Tube)
Span Gas Generation (Bronkhorst TMDs)
Controlling Software
Datalogger (Option)
UPS – Battery Modul (Option)
Dimension: 600mm(W) x 400mm(H) x 155mm(D)
Weight depends on stage of extension: 12 - 16kg

Case 2
(Zero Gas Generator)

Pump
Cartridges Silikagel for drying
Cartridges Activated Carbon, Soda lime, Molecular Sieve for Zero Gas Cleaning
Dimension: 600mm(W) x 400mm(H) x 115mm(D)
Weight: 8kg

Air Quality Monitoring
Air Quality Monitoring
HORIBA offers customer oriented tailor-made system solutions with its state-of-the-art analytical technologies and more than 50 years experience in ambient air market. As your true partner in environmental preservation, we deliver air quality monitoring, indoor air quality monitoring , clean room airborne molecular contamination monitoring , quality control and stationary emission monitoring by diluted stack gas monitoring.

Požadavek na informaci

Máte nějaké dotazy nebo požadavky? Pomocí tohoto formuláře kontaktujte naše specialisty.

* Tato pole jsou povinná.

Related products

AFCU-360M
AFCU-360M

Function Control Unit with Mass Flow Controllers

AFCU-360RC
AFCU-360RC

Function Control Unit by Remote Control

APCA-370
APCA-370

Ambient Carbon Dioxide Monitor

AQMS
AQMS

Ambient Air Quality Monitoring System

ASGU-370 series
ASGU-370 series

Automatic Span Gasgenerator Unit

ASGU-370P
ASGU-370P

Automatic Span Gas Unit for Parallel calibration

ASGU-370S
ASGU-370S

Automatic Span Gas Unit for Serial calibration

ASGU-370TS
ASGU-370TS

Automatic Span Gas Unit Transferstandard

ASS-370
ASS-370

Sampling System

ZGG-370
ZGG-370

Zero Gas Generator

AFCU-360M
AFCU-360M

Function Control Unit with Mass Flow Controllers

ASGU-370P
ASGU-370P

Automatic Span Gas Unit for Parallel calibration

ASGU-370S
ASGU-370S

Automatic Span Gas Unit for Serial calibration

ASGU-370TS
ASGU-370TS

Automatic Span Gas Unit Transferstandard

D700MG
D700MG

High Speed & Precision Pressure Insensitive Mass Flow Module

D700T
D700T

Best Performance Pressure Insensitive Mass Flow Module

D700uF
D700uF

Micro Flow Pressure Insensitive Mass Flow Module

D700WR
D700WR

Wide Range Pressure Insensitive Mass Flow Module

FS-3000
FS-3000

Thermal Flow Splitter

SEC-8000 F/D/E Series
SEC-8000 F/D/E Series

High Temperature Digital Mass Flow Controller

SEC-E Series
SEC-E Series

Mass Flow Controller

SEC-N100 Series
SEC-N100 Series

Digital Mass Flow Controller

SEC-Z500X Series
SEC-Z500X Series

Multi Range/Multi Gas Digital Mass Flow Controller

SEC-Z700S Series
SEC-Z700S Series

New concept Pressure Insensitive Mass Flow Module

SEC-Z700X Series
SEC-Z700X Series

Pressure Insensitive Mass Flow Controller

Corporate