HC-200N Specifications
| Product name | Ammonia/Nitrate Nitrogen Meter |
|---|---|
| Converter model | HC-200N |
Ammonia nitrogen
| Sensor model | AM-2000-A: Ammonia nitrogen sensor |
|---|---|
| Sensor tip model | 7691: Ammonium ion tip, 7692: Potassium ion tip for compensation, 7211: Reference tip |
| Measurement range | Concentration: 0 mg/L to 1000 mg/L (display range: 0 mg/L to 2000 mg/L) Temperature: 0℃ to 40℃ (display range: -10℃ to 110℃) |
| Display resolution | Concentration: 0.01 mg/L: 0.00 mg/L to 10.00 mg/, 0.1 mg/L: 0.0 mg/L to 100.0 mg/L, 1 mg/L: 0 mg/L to 1000mg/L Temperature: 0.1℃ |
| Repeatability | Concentration: ±3% or ±0.2 mg/L, whichever is greater for the readings (standard solution) Temperature: ±0.3℃(equivalent input) |
| Temperature compensation | Compatible temperature element: platinum resistor: 1 kΩ (0℃) Temperature measurement range: 0℃ to 40℃ Temperature calibration function: 1 point calibration for comparison with the reference thermometer |
| Potassium ion concentration compensation | Compensation range: the potassium ion concentration is not more than 10 times the ammonium ion concentration and 1000 ppm or less. Compensation error: ±20%(reading) |
| Measurable pH range | pH4 to pH8 |
| Calibration | Reference solution calibration of the ammonia nitrogen (2points) Type of the reference solution: select 1 mg/L to 10 mg/L or 10 mg/L to 100 mg/L. Additional functions: automatic defect calibration judgment, calibration history |
| Adjustment | Sample adjustment using hand analysis (1 point, 2 points*1), standard curve input function (primary system) Additional functions: adjustment history (number of days elapsed from the previous adjustment, sample adjustment coefficient) |
| Abnormal detection | Calibration error, sensor diagnosis error, converter error |
*1 When AM-2000 is connected, the 2-point sample adjustment function becomes unavailable.
Nitrate nitrogen
| Sensor model | NO-2000: Nitrate nitrogen sensor |
|---|---|
| Sensor tip model | 7693: Nitrate ion tip, 7694: Chloride ion tip for compensation, 7211: Reference tip |
| Measurement range | Concentration: 0 mg/L to 1000 mg/L (display range: 0 mg/L to 2000 mg/L) Temperature: 0℃ to 40℃ (display range: -10℃ to 110℃) |
| Display resolution | Concentration: 0.01 mg/L: 0.00 mg/L to 10.00 mg/, 0.1 mg/L: 0.0 mg/L to 100.0 mg/L, 1 mg/L: 0 mg/L to 1000mg/L Temperature: 0.1℃ |
| Repeatability | Concentration: ±3% or ±0.2 mg/L, whichever is greater for the readings (standard solution at 25℃) Temperature: ±0.3℃(equivalent input) |
| Temperature compensation | Compatible temperature element: platinum resistor: 1 kΩ (0℃) Temperature measurement range: 0℃ to 40℃ Temperature calibration function: 1 point calibration for comparison with the reference thermometer |
| Chloride ion concentration compensation | Compensation range: when the chloride ion concentration is 100 times greater than the nitrate ion concentration, a correction factor must be applied to account for interference. Compensation error: ±20%(reading) |
| Measurable pH range | pH2 to pH12 When the pH is between pH2 to pH4 or pH9 to pH12, use sensor cap AM-CAP-PVC. Chloride tip can be used in the pH2 to pH8. However, when used at pH2 to pH4, the lifetime of the tip may be shortened. |
| Measurement inhibitors | Component: if the surfactant concentration is 10mg/L or higher, sensor performance may degrade, and measurement may not be possible. |
| Calibration | Reference solution calibration of the ammonia nitrogen (2points) Type of the reference solution: select 1 mg/L to 10 mg/L or 10 mg/L to 100 mg/L. Additional functions: automatic defect calibration judgment, Calibration history |
| Adjustment | Sample adjustment using hand analysis (1 point, 2 point), standard curve input function (primary system) Additional functions: adjustment history (number of days elapsed from the previous adjustment, sample adjustment coefficient) |
| Abnormal detection | Calibration error, sensor diagnosis error, converter error |
Common specifications (Converter)
| Transmission output | 3 points, 4 mA to 20 mA DC, input/output isolation type, 900Ω(max) Select 3 items from below. Ammonia nitrogen concentration: arbitrary setting within the measurement range is possible. Nitrate nitrogen concentration: arbitrary setting within the measurement range is possible. Chloride concentration: arbitrary setting within the measurement range is possible. Temperature reading of the ammonia nitrogen meter: arbitrary setting within the range from ⁻10℃ to 110℃ is possible. Temperature reading of the nitrate nitrogen meter: arbitrary setting within the range from ⁻10℃ to 110℃ is possible. |
|---|---|
| Contact output | 5 points, No-voltage contact output, relay contact, SPST(1a),SPDT(1c) R1,R2: relay contact SPST(1a) Contact function: selectable from among the upper limit alarm, lower limit alarm, during transmission output hold, and cleaning output (closed at alarm operation, open under normal conditions and in a power off state). FAIL: relay contact SPDT(1c) Contact function: error alarms for values outside the measurement range and self check output can be set. Delay time: 0 seconds to 600 seconds R3,R4: relay contact SPST(1a) |
| Cleaning output | 2 points, Voltage contact output (connection power supply voltage output) Relay contact, SPDT(1c), SPST(1a) |
| Contact input | 1 point, Contact type: open collector no-voltage “a” contact |
| Operating temperature range | ⁻20℃ to 55℃(no freezing) |
| Operating humidity range | Relative humidity: 5% to 90%(no condensation) |
| Storage temperature | ⁻25℃ to 65℃ |
| Power supply | 100V to 240V AC ±10% 50/60Hz, Power consumption: 28 VA(max) |
| Compatible standards | CE marking, FCC Rules |
| Structure | Outdoor installation type, IP65, 50 A pole-mounted or wall-mounted, material of case: aluminium alloy, material of the mounting brackets and hood :SUS304 |
| External dimensions | 180(W)×155(H)×115(D)mm (excluding mounting brackets) |
| Mass | Mainframe: approx. 3.5kg, hood, mounting bracket: approx. 1kg |
Ammonia nitrogen sensor
| Model | AM-2000-A |
|---|---|
| Measurement range | Temperature: 0℃ to 40℃ (no freezing) |
| Measurement depth | 0m to 10m |
| Material | SUS316, FKM, PVC |
| Mass | Approx. 2.7kg (including 10m cable) |
Nitrate nitrogen sensor
| Model | NO-2000 |
|---|---|
| Measurement range | Temperature: 0℃ to 40℃ (no freezing) |
| Measurement depth | 0m to 10m |
| Material | SUS316, FKM, PVC, POM |
| Mass | Approx. 2.7kg (including 10m cable) |