HE-960RW

Panel-mount Type Resistivity Meter(Four-Wire Transmission, 2-channel)

HE-960RW connects resistivity sensor(ERF sereies) and measures resistivity and temperature in the sample water.
This resistivity meter is ideal for such applications as the high-precision water monitoring employed at ultra-pure water plants used in semiconductor manufacturing.
They utilize newly designed, high-precision, high-stability temperature measurement circuitry and a vastly improved temperature compensation function, an important element for measuring the resistivity of ultra-pure water.

 

Measuring range

Resistivity: 0 - 100.0 MΩ・cm, 0 - 1000 kΩ・m
Temperature: 0 - 100 ℃

Division: Process Water
Manufacturing Company: HORIBA Advanced Techno Co., Ltd.

 

  • Highly precise, highly stable temperature compensation function
    Control fluctuations in measured values in the region of 18 MΩ·cm resistivity to within a minimum 0.02 MΩ·cm over a water temperature range of 15 °C to 35 °C.
  • 50 m extension possible for sensor cables
  • 2-channel simultaneous measurement
  • Independent 4 contact alarms
  • Abundant in-house calibration equipment
    •HORIBA Advanced Techno resistivity meters are only shipped after cellconstant inspection is performed on the resistivity sensors and inspectionfor temperature sensor instrumental errors is implemented using calibration equipment that has been adjusted with high-traceability reference equipment.
    •The sensors can also be combined with a converter for integrated calibration in advance of shipping.
  • Communication device ability (RS-485)
  • Utilization of lead-free solder

 

 

Product nameIndustrial 2-channel specific resistance meter
ModelHE-960RW
Measurement
method
Electrode type (2-electrode method)
Sensor input2 channels (for concurrent measurement with sensors isolated each other)
Cell constant0.01/cm
Temperature sensor
specifications
Platinum resistance 1000 Ω/0℃
Measuring rangeMeasurement unitkΩ•m0 to 20.00 to 200.00 to 1000 *
MΩ•cm0 to 2.000 to 20.000 to 100.0 *
*: Measurable without temperature compensation
Temperature    
  
0℃ to 100℃
(The number of digits after the decimal point is selectable from one and two. The range of measurements is −20℃ to 120℃.)
Desalination rate0% to 100%
Temperature: 0℃ to 100℃ (Select your desired decimal point from 0, 1, and 2 digits.)
RepeatabilityWithin ±0.1% of the full scale (in equivalent input)
LinearityWithin ±0.5% of the full scale (in equivalent input)
Transmission
output
Number of outputs: 2
4 mA to 20 mA DC/0 mA to 20 mA DC, input/output isolated type
Maximum load resistance: 900 Ω
Transmission output range: Freely selectable within the measurement range
(Negative terminals of each transmission output channel are connected inside and thus have the same electric potential.)
Contact outputNumber of outputs: 4
Alarm contact outputs (R1, R2, and R3)
  Contact type: relay contact, SPST (1a)
  Contact rating: 240 V AC, 3 A and 30 V DC, 3 A (resistance load)
  Contact function: selectable from the upper/lower limit action (ON/OFF control), delay, and hysteresis
  Selectable from the selected measurement, anomaly alarm, and maintenance.
Alarm contact output (R4)
  Contact type: relay contact, SPDT (1c)
  Contact rating: 240 V AC, 3 A and 30 V DC, 3 A (resistance load)
  Contact function: selectable from the upper/lower limit action (ON/OFF control), delay, and hysteresis
  Selectable from the selected measurement, anomaly alarm, and maintenance.
  (However, R1 and R2, and R3 and R4 share the common contacts respectively.)
Calibration functionSpecific resistance: Based on the specified compensation coefficient for cell constant (parameter input)
Temperature: Calibrated by comparing with the reference thermometer
Communication
output
RS-485 input/output
Transmission
output hold feature
 
  • Previous value hold
  • Optional value hold
    Selectable from the above (However, only the previous value hold is available in the maintenance mode.)
 
Self-diagnosis
function
 
  • Sensor diagnosis
    Short-circuit and disconnection of the temperature sensor
  • Out of the measurement range
  • Converter error
 
Temperature
compensation
 
  • Temperature compensation for extra-deionized water and impurities
      Select the temperature characteristics of impurities
      - NaCl temperature characteristics
      - Arbitrary temperature coefficient entry (temperature coefficient: 5%/℃)
      Reference temperature: 5℃ to 95℃
  • No temperature compensation is performed.
 
Temperaturecompensated
range
0℃ to 100℃
Extra deionized
water specific
resistance selection
Measurement
unit
kΩ•m182.3 (standard), 181.8, 182.4Select from options shown on the left.
MΩ•cm18.23 (standard), 18.18, 18.24
Clipping functionWhen the measured value is above the upper limit of the measurement range derived from the specified specific resistance, the specified resistance is used as the measured value.
Ambient
temperature
−5℃ to 45℃
Relative humidity20% to 85% (without dew condensation)
Storage
temperature
−25℃ to 65℃
Power supplyRated voltage 100 V to 240 V AC, 50/60 Hz, 10 VA (max.)
StructureIndoor-use panel installation type
Panel case: ABS, Terminal: PBT
Panel: IP65 dust and water proof structure
Protective structurePanel: IP65 (IEC60529, JIS C0920)
Rear case: IP20, Terminal:IP00
Class II device (IEC61010-1)
Pollution level 2 (IEC61010-1)
Conforming
standards
CE MarkingEMC Directives: EN61326-2-3
Low Voltage Directive: EN61010-1
RoHS Directive: EN50581
FCC RuleFCC Part15
External
dimensions
96 (W) mm × 96 (H) mm × 115 (D) mm
Case depth: approx. 105 mm (when panel-mounted)
MassApprox. 550 g
Compatible sensorsERD/ERF-series specific resistance sensor, cell constant 0.01/cm

Request for Information

Do you have any questions or requests? Use this form to contact our specialists. * These fields are mandatory.

Related products

1000-EC-1288
More 1000-EC-1288

Conductivity Standard Solution

1000-EC-1413
More 1000-EC-1413

Conductivity Standard Solution

1000-EC-84
More 1000-EC-84

Conductivity Standard Solution

250-EC-1288
More 250-EC-1288

Conductivity Standard Solution

250-EC-1413
More 250-EC-1413

Conductivity Standard Solution

250-EC-147
More 250-EC-147

Conductivity Standard Solution

250-EC-84
More 250-EC-84

Conductivity Standard Solution

500-EC-1288
More 500-EC-1288

Conductivity Standard Solution

500-EC-1413
More 500-EC-1413

Conductivity Standard Solution

500-EC-84
More 500-EC-84

Conductivity Standard Solution

514-22
More 514-22

1.41 mS/cm Conductivity Standard Solution

514-23
More 514-23

12.9 mS/cm Conductivity Standard Solution

CS-600F
More CS-600F

Fiber Optic Type Chemical Concentration Monitor

CS-620F
More CS-620F

Optical Fiber Type Hot Phosphoric Acid Concentration Monitor

CS-900
More CS-900

Non-Contact Chemical Concentration Monitor

HC-200F
More HC-200F

Field-installation Type Simplified Fluoride Ion Concentration Meter(Four-Wire Transmission)

HC-200NH
More HC-200NH

Field-installation Type Ammonia Nitrogen Meter(Four-Wire Transmission)

HC-300F
More HC-300F

Field-installation Type Simplified Fluoride Ion Concentration Meter(Two-Wire Transmission)

HD-200
More HD-200

Field-installation Type Dissolved Oxygen Meter (Four-Wire Transmission, Membrane Type)

HD-200FL
More HD-200FL

Field-installation Type Dissolved Oxygen Meter (Four-Wire Transmission, Optical Type)

HD-300
More HD-300

Field-installation Type Dissolved Oxygen Meter(Two-Wire Transmission, Membrane Type)

HD-480
More HD-480

Panel-mount Type Dissolved Oxygen Meter (Four-Wire Transmission, Membrane Type)

HD-960L
More HD-960L

Dissolved Oxygen Monitor in Low Concentration

HE-200C
More HE-200C

Field-installation Type Electric Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HD-200
More HD-200

Field-installation Type Dissolved Oxygen Meter (Four-Wire Transmission, Membrane Type)

HD-300
More HD-300

Field-installation Type Dissolved Oxygen Meter(Two-Wire Transmission, Membrane Type)

HD-480
More HD-480

Panel-mount Type Dissolved Oxygen Meter (Four-Wire Transmission, Membrane Type)

HD-960L
More HD-960L

Dissolved Oxygen Monitor in Low Concentration

HE-200C
More HE-200C

Field-installation Type Electric Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HE-200H
More HE-200H

Field-installation Type Electric Conductivity Meter (Four-Wire Transmission, For High-concentration)

HE-200R
More HE-200R

Field-installation Type Electric Resistivity Meter (Four-Wire Transmission)

HE-300C
More HE-300C

Field-installation Type Electric Conductivity Meter (Two-Wire Transmission, For Low-concentration)

HE-300R
More HE-300R

Field-installation Type Electric Resistivity Meter (Two-Wire Transmission)

HE-480C
More HE-480C

Panel-mount Type Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HE-480C-GC
More HE-480C-GC

Carbon Sensor Conductivity Meter (Low concentration type)

HE-480H
More HE-480H

Panel-mount Type Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HE-480R
More HE-480R

Panel-mount Type Resistivity Meter(Four-Wire Transmission)

HE-480R(W)
More HE-480R(W)

Industrial resistivity meter

HE-960CA
More HE-960CA

Citric Acid Monitor

HE-960CW
More HE-960CW

Panel-mount Type Conductivity Meter (Four-Wire Transmission, 2-channel)

HE-960H-TM
More HE-960H-TM

Wide range TMAH Concentration Monitor

HE-960H-TM-S
More HE-960H-TM-S

High Precision TMAH Concentration Monitor

HE-960HC
More HE-960HC

Carbon Sensor Conductivity Meter (High concentration type)

HE-960HI
More HE-960HI

Panel-mount Type Conductivity Meter (Four-Wire Transmission, For Wide Range)

HE-960LC
More HE-960LC

Carbon Sensor Conductivity Meter

HE-960LF / FS-09F-1/2
More HE-960LF / FS-09F-1/2

Flat Carbon Sensor Conductivity meter

HE-960R-GC(W)
More HE-960R-GC(W)

Carbon Sensor Resistivity Meter

HE-960RW-GC(W)
More HE-960RW-GC(W)

2-Channel Resistivity Meter

HE-960TM
More HE-960TM

TMAH Conductivity Meter. Perfect for Controlling TMAH Developer Concentrations

HF-960H
More HF-960H

HF / HCl Concentration Monitor

HF-960M
More HF-960M

Low Concentration Type HF/HCl/NH3 Concentration Monitor

HF-SP-CU
More HF-SP-CU

2-channel High Precision HF Concentration Monitor

HO-200
More HO-200

Field-installation Type ORP Meter (Four-Wire Transmission)

HO-300
More HO-300

Field-installation Type ORP Meter (Two-Wire Transmission)

HO-480
More HO-480

Panel-mount Type ORP Meter (Four-Wire Transmission)

HR-200
More HR-200

Feild-installation Type Residual Chlorine Meter (Four-Wire Transmission, Water flow beads)

HR-200RT
More HR-200RT

Field-installation Type Residual Chlorine Meter (Four-Wire Transmission, Rotating Type)

HR-480
More HR-480

Panel-mount Type Residual Chlorine Meter (Four-Wire Transmission)

HT-110
More HT-110

Total Organic Carbon Monitor

LAQUA DO210
More LAQUA DO210

Handheld Water Quality Meters

LAQUA DO220
More LAQUA DO220

Handheld Water Quality Meters

LAQUA DS-72
More LAQUA DS-72

Benchtop Water Quality Meters

LAQUA EC1100
More LAQUA EC1100

Benchtop Water Quality Meters

LAQUA EC210
More LAQUA EC210

Handheld Water Quality Meters