MEXA-ONE
Overview
HORIBA Awarded “2012 Hardware Innovation of the Year Award” for MEXA-ONE Design
_________________________________________________
Reliable・Efficient・Expandable
MEXA-ONE offers an intuitive user interface with a highly efficient hardware and software design.
This results in increased testing efficiency and economical facility operation, while enhancing reliability and accuracy. These advancements are possible because the MEXA-ONE software employs new "HORIBA ONE PLATFORM". This platform integrates the test devices in an emission cell into a single user interface, increasing efficiency and optimizing user control over the entire testing process.
Features
Increased Test Efficiency
MEXA-ONE incorporates HORIBA's leading-edge technology to enhance reliability and performance beyond today's expectations.
Improved durability and maintenance assure efficient test facility operation, reducing overall test duration and accelerating engine and vehicle development.
Faster Response and Shorter Test Times
Fully automated, customer-defined, pre-test routines ensure system readiness for testing. Overall test duration is minimized by reducing analyzer response and wait times between measurements.
- 50% reduction in analyzer response times (t99) *
- 30% reduction in analyzer calibration waiting times *
- Optimization of analyzer purging times
* By comparison with HORIBA's conventional products
Lower Cost of Ownership
Savings are realized through reduced operational costs, with a focus on reduction of consumables and facility requirements.
- 10% reduction in power consumption *
- Filter element replacement is eliminated due to the use of the automatic purge function for the back flushing filter
- 30% reduction in analyzer calibration gas consumption *
* By comparison with HORIBA's conventional products
Improved Test Facility Operation
Enhanced Maintenance Support
Ensuring Accurate Measurement
Automatic notifications of periodic inspections and adjustments are generated as required by emission regulations in accordance with a user-defined schedule. Inspections and adjustments can also be started from the control window.
Preventative Maintenance Feature
This automatic function provides advanced notification for the replacement of consumable parts. This process enables proactive maintenance to be performed.
MEXA-ONE automatically monitors analyzer sensitivity and displays the request for readjustment before exceeding the permissible range.
Effective Troubleshooting
When an alarm occurs, the MEXA-ONE not only displays details of the alarm but also generates a display with troubleshooting instructions. Quick alarm resolution enables effective testing.
High Performance and Durability
MEXA-ONE exceeds the durability seen in about 4,500 MEXA-7000 units in operation around the world. For example, the entire sample handling system has undergone a major upgrade to optimize sample flow and to reduce pump load.
Wide Application Range
Evaluation of NOx After-Treatment Catalyst Systems
Measurement of nitrogen compounds (NO, NO2, N2O, NH3) is essential for evaluation of NOx after-treatment systems. MEXA-ONE can be easily configured to provide optimum measurement capability based on the testing objective.
Close-Coupled Transient EGR Measurement
To deliver faster response and more accurate EGR measurement, MEXA-ONE incorporates new EGR sample handling and analysis in a compact cabinet.
Multi-point EGR Measurement
・Multi-point measurement can now be performed on complete EGR systems using MEXA-ONE's modular design.
Manufactured by HORIBA
Specifications
MEXA-ONE System Line-up
MEXA-ONE is a flexible system allowing configuration for a wide range of applications.
OPTION / FUNCTION
・Remote EGR (R-EGR-01)
・Remote EGR (R-EGR-02H)
・Remote Tracer (R-TR-01)
・Heated Filter with back flush purge (dual type) (F-02HB)
・Heated Filter with back flush purge (F-01HB)
・Heated Filter (F-01H)
・Span Gas Selector (SGS)
・Remote Multi Gas Controller (MGC-0XM)
・Gas Divider and Converter Checker Unit (high accurate type) (GDC-ONE)
・Gas Divider and Converter Checker Unit (GDC-703)
・Gas Divider and Converter Checker Unit (base model type) (GDC-Lite)
・Leak Checker (LCK-01)
・Heated Bubbler (HCU-700)
Standard
Measurement | Model | Analyzer unit | Principle※1 | Range※2 |
---|---|---|---|---|
CO | AIA-11 | Half 19 Inch | NDIR | 0-50 ~ 0-5000 ppm |
CO | AIA-31 | Half 19 Inch | NDIR | 0-0.5 ~ 0-12 vol% |
CO | AlA-41 | Half 19 Inch | NDIR | 0-3 ~ 0-20 vol% |
CO2 | AlA-22 | Half 19 Inch | NDIR | 0-0.1 ~ 0-6 vol% |
CO2 | AlA-32 | Half 19 Inch | NDIR | 0-0.5 ~ 0-20 vol% |
CO2 | AlA-42 | Half 19 Inch | NDIR | 0-3 ~ 0-20 vol% |
HC | AlA-14 | Half 19 Inch | NDIR | 0-100 ~ 0-5000 ppm |
HC | AlA-34 | Half 19 Inch | NDIR | 0-5000 ~ 0-10000 ppm |
N2O | AlA-15 | Half 19 Inch | NDIR | 0-100 ~ 0-5000 ppm |
O2 | MPA-01 | Half 19 Inch | MPD | 0-1 ~ 0-25 vol% |
THC | FIA-01 | Half 19 Inch | FID | 0-10 ~ 0-20000 ppmC |
NO/NOx | CLA-01 | Half 19 Inch | CLD | 0-10 ~ 0-10000 ppm |
CH4 | GFA-01 | Half 19 Inch | GC-FID | 0-10 ~ 0-3000 ppm |
THC | FIA-01H | 19 Inch | Heated-FID | 0-10 ~ 0-60000 ppmC |
THC,CH4,NMHC | FIA-02H-NC | 19 Inch | Heated-FID | THC 0-10 ~ 0-5000 ppmC |
THC,CH4,NMHC | FIA-02H-ND | 19 Inch | Heated-FID | THC 0-50 ~ 0-60000 ppmC |
NO/NOx | CLA-01HV | 19 Inch | Heated-CLD | 0-10 ~ 0-10000 ppm |
NO,NOx,No2 | CLA-02HV | 19 Inch | Dual Heated-CLD | NO 0-10 ~ 0-10000 ppm |
THC | FIA-01O | OVN | Heated-FID | 0-10 ~ 0-60000 ppmC |
THC,CH4,NMHC | FIA-02O-NC | OVN | Heated-FID | THC 0-10 ~ 0-5000 ppmC |
THC,CH4,NMHC | FIA-02O-ND | OVN | Heated-FID | THC 0-50 ~ 0-60000 ppmC |
NO/NOx | CLA-01OV-2 | OVN | Heated-CLD | 0-10 ~ 0-10000 ppm |
NO,NOx | CLA-02OV-3 | OVN | Dual heated-CLD | NO 0-10 ~ 0-10000 ppm |
Low Emission Measurement
Measurement | Model | Analyzer unit | Principle※1 | Range※2 |
---|---|---|---|---|
CO | AIA-11SL | 19 Inch | NDIR | 0-10 ~ 0-1000 ppm |
CO2 | AIA-22 | Half 19 Inch | NDIR | 0-0.1 ~ 0-6 vol% |
THC | FIA-01SL | Half 19 Inch | FID | 0-1 ~ 0-500 ppmC |
NO/NOx | CLA-01SL | Half 19 Inch | CLD | 0-1 ~ 0-500 ppm |
CH4 | GFA-01SL | Half 19 Inch | GC-FID | 0-1 ~ 0-500 ppm |
Remote Type (Option)
Measurement | Model | Analyzer unit | Principle※1 | Range※2 |
---|---|---|---|---|
CO2 | R-EGR-01 | Remote | NDIR Dry 1Line | 0-10 ~ 0-20 vol% |
CO2 | R-TR-01 | Remote | NDIR Dry 1Line | 0-10 ~ 0-20 vol% |
CO2 | R-EGR-02H | Remote | NDIR Wet 2Line | 0-10 ~ 0-20 vol% |
※1
NDIR : Non Dispersive Infrared Detector
FID : Flame Ionization Detector
GC-FID : Flame lonization Detector with Gas Chromatography
NMC-FID : Flame lonization Detector with Non Methane Cutter
CLD : Chemiluminescence Detector
CLD[Wet/Dry] : Chemiluminescence Detector [Wet/Dry switchable]
MPD : Magnetopneumatic Detector
※2 Other ranges on request
System Specifications
- Dimension
-Standard 19 inch Rack・・・655(W) × 855(D) × 1970(H) mm
-Oven Type Heated Analyzer・・・430(W) × 550(D) × 1100(H) mm - Mass・・・Depends on system (e.g. MEXA-ONE–D1(OVN-type) = Approx. 350 kg)
- Ambient temperature・・・5 deg.C to 40 deg.C
- Ambient humidity・・・80% or less as relative humidity
- Ambient Pressure・・・80 kPa to 102 kPa (abs)
(Altitude below 2000 m above sea-level)