CS-100 Series

Stand-alone Type Chemical Concentration Monitor

A series of chemical concentration monitors for various chemicals used in the wet process.

The optimal model to suit chemicals from among over 100 different applications can be chosen.  Measurements of the concentration of each component can be taken in real-time, providing notifications using alarms to signal the timing of chemical exchange and automatic replenishment. Short measurement cycles to faithfully track concentration changes can be achieved.

Chemical Concentration

AC(100-240V)Transmission OutputContact OutputRS-232CMulti Component

Segment: Semiconductor
Manufacturing Company: HORIBA Advanced Techno Co., Ltd.

Real-time concentration tracking

Achieve concentration management for a 300mm process with measurement cycles of approximately 3 seconds. Supports precise concentration management for various types of cleaning equipment.

Simple management

Measurement is fully automated, without the need for manual control once the measurement has started. Users can achieve easy management by simply injecting the chemical.  Furthermore, since reference spectrum measurements use air, water is not required as a utility for routine measurements.

Prevention of bubbles

A degassing function has been incorporated to separate bubbles from liquids just before the flow cell.  Possible to take continuous measurements while the liquid is flowing.

Model name

CS-100
Measurement principleAbsorption spectroscopic method
Sample temperature20 to 30 Degree C
Ambient temperature20 to 25 Degree C
ComponentsMax. 4 components
Chemical rangeMax. 4 ranges
CommunicationParallel I/O, Analog output, RS-232C
Analog output
(4-20 mA)
Max. 2 components
Dimension205(W) X 329(D) X 269(H)mm
Power sourceDC 24V
Consumable partsHalogen lamp
WavelengthUV/NIR
Wetted materialPTFE, PFA, Sapphire or Quartz

Schematics

 

 

μ œν’ˆ 문의

HORIBAμ œν’ˆμ˜ μžμ„Έν•œ 정보λ₯Ό μ›ν•˜μ‹œλ©΄, μ•„λž˜μ˜ 양식에 λ‚΄μš©μ„ μž…λ ₯을 λΆ€νƒλ“œλ¦½λ‹ˆλ‹€.

* λŠ” ν•„μˆ˜μž…λ ₯ν•­λͺ©μž…λ‹ˆλ‹€.

Related products

CS-620F
CS-620F

κ΄‘μ„¬μœ ν˜• 고온 인산 농도 λͺ¨λ‹ˆν„°

CS-900
CS-900

비접촉 ν™”ν•™λ¬Όμ§ˆ 농도 λͺ¨λ‹ˆν„°

HD-960L
HD-960L

저농도 용쑴 μ‚°μ†Œ λͺ¨λ‹ˆν„°

HD-960LR
HD-960LR

용쑴 μ‚°μ†Œ 농도 λͺ¨λ‹ˆν„°

HE-480C-GC
HE-480C-GC

μΉ΄λ³Έ μ„Όμ„œ 전도도계 (μ €λ†λ„ν˜•)

HE-960CA
HE-960CA

ꡬ연산 λͺ¨λ‹ˆν„°

HE-960H-KOH
HE-960H-KOH

KOH λͺ¨λ‹ˆν„°

HE-960H-TM-S
HE-960H-TM-S

κ³ μ •λ°€ TMAH 농도 λͺ¨λ‹ˆν„°

HE-960HC
HE-960HC

μΉ΄λ³Έ μ„Όμ„œ 전도도계 (κ³ λ†λ„ν˜•)

HE-960LC
HE-960LC

μΉ΄λ³Έ μ„Όμ„œ 전도도계

HE-960LF / FS-09F-1/2
HE-960LF / FS-09F-1/2

평탄 μΉ΄λ³Έ μ„Όμ„œ 전도도계

HE-960RW-GC(W)
HE-960RW-GC(W)

2-채널 μ €ν•­λ₯ κ³„

HF-700A
HF-700A

ν™©μ‚°/κ³Όμ‚°ν™”μˆ˜μ†Œ λͺ¨λ‹ˆν„° (저농도)

HF-960EM
HF-960EM

인라인 μ„Όμ„œ 및 μžλ™ λ²”μœ„ μ „ν™˜ 농도 λͺ¨λ‹ˆν„°

HF-SP-CU
HF-SP-CU

2-채널 κ³ μ •λ°€ HF 농도 λͺ¨λ‹ˆν„°

HT-110
HT-110

μ΄μœ κΈ°νƒ„μ†Œ λͺ¨λ‹ˆν„°

HZ-960
HZ-960

μš©ν•΄ 였쑴 λͺ¨λ‹ˆν„°

HZ-960HPO-M
HZ-960HPO-M

H2O2 λͺ¨λ‹ˆν„°

OPSA-150
OPSA-150

μœ κΈ°μ˜€μ—Όλ¬Όμ§ˆ λͺ¨λ‹ˆν„°

SLIA-300
SLIA-300

고감도 싀리카 뢄석기

SLIA-5000
SLIA-5000

싀리카 μΈ‘μ •κΈ°

TPNA-500
TPNA-500

μžλ™ μ΄μ§ˆμ†Œ/총인 μΈ‘μ •κΈ°

Ultima Expert LT
Ultima Expert LT

Affordable high performance ICP-OES

UP-100
UP-100

마이크둜 λ³Όλ₯¨ pH λͺ¨λ‹ˆν„°

CS-620F
CS-620F

κ΄‘μ„¬μœ ν˜• 고온 인산 농도 λͺ¨λ‹ˆν„°

CS-900
CS-900

비접촉 ν™”ν•™λ¬Όμ§ˆ 농도 λͺ¨λ‹ˆν„°

HU-200SS
HU-200SS

ν˜„μž₯μ„€μΉ˜ν˜• MLSS Meter (4-Wire Transmission)

HU-200TB-H
HU-200TB-H

ν˜„μž₯μ„€μΉ˜ν˜• 탁도계 (4-Wire Transmission, High-sensitivity)

HU-200TB-IM
HU-200TB-IM

κ³΅μ •μš© μ‚½μž…ν˜• SS/탁도 μΈ‘μ •κΈ°

HU-200TB-W
HU-200TB-W

ν˜„μž₯ μ„€μΉ˜ν˜• 탁도계 (4-Wire Transmission, For Wide Range)

HZ-960
HZ-960

μš©ν•΄ 였쑴 λͺ¨λ‹ˆν„°

HZ-960HPO-M
HZ-960HPO-M

H2O2 λͺ¨λ‹ˆν„°

OPSA-150
OPSA-150

μœ κΈ°μ˜€μ—Όλ¬Όμ§ˆ λͺ¨λ‹ˆν„°

TPNA-500
TPNA-500

μžλ™ μ΄μ§ˆμ†Œ/총인 μΈ‘μ •κΈ°

U-50 Series
U-50 Series

λ‹€ν•­λͺ© 수질 μΈ‘μ •κΈ°

Corporate