HZ-960

Dissolved Ozone Monitor HZ-960,H2O2 Monitor HZ-960HPO-M

μš©ν•΄ 였쑴 λͺ¨λ‹ˆν„°

HZ-960은 κ³ μ •λ°€, κ΄‘μ—­ μš©ν•΄ 였쑴 λͺ¨λ‹ˆν„°μž…λ‹ˆλ‹€. λ°˜λ³΅μ„±: F.S. +/- 0.2%. 4κ°€μ§€ μœ ν˜•μ˜ μΈ‘μ • λ²”μœ„ 인라인 디텍터λ₯Ό 선택할 수 μžˆμŠ΅λ‹ˆλ‹€.

Segment: Semiconductor
Manufacturing Company: HORIBA Advanced Techno Co., Ltd.
  • High precision. Repeatability: F.S. +/- 0.2%
  • Wide range measurement
         0 - 10 mg/L (ZH-10 Sensor)
         0 - 40 mg/L (ZH-40 Sensor)
         0 - 100 mg/L (ZH-100 Sensor)
         0 - 500 mg/L (ZH-500 Sensor)
  • Remote calibration
  • RoHS compliant
Corresponding detectorZH-10ZH-40ZH-100ZH-500
Measurement range0 - 10.00mg/L0 - 40.00mg/L0 - 100mg/L0 - 500mg/L
Supply temperature                   5 - 30 deg.C5 - 80 deg.C
Chemical contact material of detectorPFA, PTFE, quartz glass
Supply pressureWithin 0.5 MPa
Repeatability+/- 0.2% of full scale
Linearity+/- 1.0% of full scale
Transmission outputNumber of output: 2
Contact outputNumber of output: 5
Contact inputNumber of input: 2
Communication outputRS-485
Power supplyRated voltage 24 +/- 10% V DC, 15W

Schematics

μ œν’ˆ 문의

HORIBAμ œν’ˆμ˜ μžμ„Έν•œ 정보λ₯Ό μ›ν•˜μ‹œλ©΄, μ•„λž˜μ˜ 양식에 λ‚΄μš©μ„ μž…λ ₯을 λΆ€νƒλ“œλ¦½λ‹ˆλ‹€.

* λŠ” ν•„μˆ˜μž…λ ₯ν•­λͺ©μž…λ‹ˆλ‹€.

Related products

CS-620F
CS-620F

κ΄‘μ„¬μœ ν˜• 고온 인산 농도 λͺ¨λ‹ˆν„°

CS-900
CS-900

비접촉 ν™”ν•™λ¬Όμ§ˆ 농도 λͺ¨λ‹ˆν„°

HD-960L
HD-960L

저농도 용쑴 μ‚°μ†Œ λͺ¨λ‹ˆν„°

HD-960LR
HD-960LR

용쑴 μ‚°μ†Œ 농도 λͺ¨λ‹ˆν„°

HE-480C-GC
HE-480C-GC

μΉ΄λ³Έ μ„Όμ„œ 전도도계 (μ €λ†λ„ν˜•)

HE-960CA
HE-960CA

ꡬ연산 λͺ¨λ‹ˆν„°

HE-960H-KOH
HE-960H-KOH

KOH λͺ¨λ‹ˆν„°

HE-960H-TM-S
HE-960H-TM-S

κ³ μ •λ°€ TMAH 농도 λͺ¨λ‹ˆν„°

HE-960HC
HE-960HC

μΉ΄λ³Έ μ„Όμ„œ 전도도계 (κ³ λ†λ„ν˜•)

HE-960LC
HE-960LC

μΉ΄λ³Έ μ„Όμ„œ 전도도계

HE-960LF / FS-09F-1/2
HE-960LF / FS-09F-1/2

평탄 μΉ΄λ³Έ μ„Όμ„œ 전도도계

HE-960RW-GC(W)
HE-960RW-GC(W)

2-채널 μ €ν•­λ₯ κ³„

HF-960EM
HF-960EM

인라인 μ„Όμ„œ 및 μžλ™ λ²”μœ„ μ „ν™˜ 농도 λͺ¨λ‹ˆν„°

HF-SP-CU
HF-SP-CU

2-채널 κ³ μ •λ°€ HF 농도 λͺ¨λ‹ˆν„°

HT-110
HT-110

μ΄μœ κΈ°νƒ„μ†Œ λͺ¨λ‹ˆν„°

HZ-960
HZ-960

μš©ν•΄ 였쑴 λͺ¨λ‹ˆν„°

HZ-960HPO-M
HZ-960HPO-M

H2O2 λͺ¨λ‹ˆν„°

OPSA-150
OPSA-150

μœ κΈ°μ˜€μ—Όλ¬Όμ§ˆ λͺ¨λ‹ˆν„°

SLIA-300
SLIA-300

고감도 싀리카 뢄석기

SLIA-5000
SLIA-5000

싀리카 μΈ‘μ •κΈ°

TPNA-500
TPNA-500

μžλ™ μ΄μ§ˆμ†Œ/총인 μΈ‘μ •κΈ°

Ultima Expert LT
Ultima Expert LT

Affordable high performance ICP-OES

UP-100
UP-100

마이크둜 λ³Όλ₯¨ pH λͺ¨λ‹ˆν„°

CS-620F
CS-620F

κ΄‘μ„¬μœ ν˜• 고온 인산 농도 λͺ¨λ‹ˆν„°

CS-900
CS-900

비접촉 ν™”ν•™λ¬Όμ§ˆ 농도 λͺ¨λ‹ˆν„°

HU-200SS
HU-200SS

ν˜„μž₯μ„€μΉ˜ν˜• MLSS Meter (4-Wire Transmission)

HU-200TB-H
HU-200TB-H

ν˜„μž₯μ„€μΉ˜ν˜• 탁도계 (4-Wire Transmission, High-sensitivity)

HU-200TB-IM
HU-200TB-IM

κ³΅μ •μš© μ‚½μž…ν˜• SS/탁도 μΈ‘μ •κΈ°

HU-200TB-W
HU-200TB-W

ν˜„μž₯ μ„€μΉ˜ν˜• 탁도계 (4-Wire Transmission, For Wide Range)

HZ-960
HZ-960

μš©ν•΄ 였쑴 λͺ¨λ‹ˆν„°

HZ-960HPO-M
HZ-960HPO-M

H2O2 λͺ¨λ‹ˆν„°

OPSA-150
OPSA-150

μœ κΈ°μ˜€μ—Όλ¬Όμ§ˆ λͺ¨λ‹ˆν„°

TPNA-500
TPNA-500

μžλ™ μ΄μ§ˆμ†Œ/총인 μΈ‘μ •κΈ°

U-50 Series
U-50 Series

λ‹€ν•­λͺ© 수질 μΈ‘μ •κΈ°