EMIA-20XC

High-Concentration Carbon Analyzer

Highly Repeatable Carbon Analysis for Precise Control of High-Carbon Materials

Precise control of carbon concentration is critical in the production of tungsten carbide and other carbon-containing powders. 
The EMIA-20XC from EMIA-Expert series is designed for the precise analysis of high-carbon-content materials, delivering accurate, highly repeatable results and reliable long-term reproducibility. Its dedicated XC detection unit, optimized for high-carbon applications, minimizes the effects of atmospheric pressure and temperature fluctuations, enabling consistent measurements in a short time. The built-in switching function also enables the analysis of carbon and sulfur at low-ppm concentrations, combining high-concentration carbon analysis with versatile carbon/sulfur measurement in a single system.

Main Features

  •  RSD ≤ 0.15% and approximately 160 seconds in XC Mode

In XC Mode, the analyzer achieves a relative standard deviation (RSD) of ≤ 0.15% for high-carbon-content materials such as tungsten carbide. Results are displayed in approximately 160 seconds from measurement start.

  •  2-in-1 Cemented Carbide Carbon and Inorganic Carbon /Sulfur Determination

By switching the modes, the EMIA-20XC supports both high-concentration carbon analysis and low-concentration carbon and sulfur analysis.

  •  Optional autosampler is available.
Segment: Scientific
Manufacturing Company: HORIBA, Ltd.

Proprietary Technology for High-Repeatability Measurement 

  • The detection unit (XC unit), specialized for measuring high-carbon-content materials, minimizes the effects of atmospheric pressure and room temperature fluctuations, enabling high-repeatability measurements in a short time. 
  • Relative standard deviation (RSD) ≤ 0.15%, demonstrating outstanding reproducibility, for high-carbon-content materials, such as tungsten carbide.
  • Approximately 160 seconds from measurement start to results display: high-repeatability measurement mode (XC mode).


The Gas Flow

The EMIA-20XC enables switching between high-repeatability measurement of high-concentration carbon and measurement of low-concentration carbon and sulfur. 


Applications*

*Application examples are based on representative evaluations conducted with EMIA-20XC and/or EMIA-Pro/Expert. Results and repeatability depend on sample composition, homogeneity, concentration, particle size, pretreatment, calibration, and other measurement conditions. The specified RSD  0.15% applies only under the specified measurement conditions and is not guaranteed for all sample types. Please contact HORIBA before purchase to confirm the feasibility of your application and recommended measurement conditions.

 

 

EMIA-Expert series: EMIA-20XC Specifications by Operating Mode
 XC ModeStandard Mode
Measurement PrincipleHigh-frequency induction furnace combustion – infrared absorption method
Sample MassMax 0.50 or less than 0.49 ± 0.01 gLess than 1.00 ± 0.10 g
Measurement Time (Average)Approx. 160 secondsApprox. 60 seconds
CarbonMeasurement Range *21.0% - 20.0%0.6 ppm - 10.0%
Reproducibility *3

RSD ≤ 0.15%

σ ≤ 0.3 ppm (Sample less than 20 ppm),
σ ≤ 1 ppm or RSD ≤ 0.5% (Sample more than 20 ppm)
SulfurMeasurement Range *2-0.6 ppm - 1.0%
Reproducibility *3-σ ≤ 0.3 ppm (Sample less than 20 ppm),
σ ≤ 1 ppm or RSD ≤ 0.75% (Sample more than 20 ppm)

Utility

Carrier GasOxygen (Purity: 99.5% or higher, 0.30 - 0.33 MPa)
Operation GasNitrogen (Purity: 99.5% or higher, 0.40 - 0.45 MPa)

Dimensions (W x D x H mm) and Mass (kg)

Main Unit500 x 725 x 710 mm/approx. 134 kg*4
Purifier/Oxidizer160 x 560 x 512 mm/approx. 28 kg
XC Unit260 x 560 x 513 mm/approx. 37 kg

*1 Varies depending on the sample, measurement conditions, and options.
*2 Maximum range is extended by reducing the sample mass.
*3 Guaranteed values apply and are limited to the following conditions: When using reliable standards and using official consumables (accelerators, crucible, reagents, others).
*4 Excludes protrusions on the rear panel.

Available Options

  • Auto Sampler

Up to 20 samples can be loaded. The system automatically places crucibles in the furnace and disposes of them after measurements. Measurements can also be manually interrupted when necessary. 

 

 

  • Halogen Trap Unit

HT-03 Traps halogen derived from sample, allowing analysis with minimized influence.can be loaded. The system automatically places crucibles in the furnace and disposes of them after measurements. 

 


제품 문의

HORIBA제품의 자세한 정보를 원하시면, 아래의 양식에 내용을 입력을 부탁드립니다.

* 는 필수입력항목입니다.

Related products

EMIA-Expert
EMIA-Expert

탄소/황 분석기

EMIA-Pro
EMIA-Pro

탄소/유황 분석기

EMIA-Step
EMIA-Step

탄소/황 분석기 (인덕션 퍼니스 타입)

EMGA-Expert
EMGA-Expert

산소/질소/수소 분석기

EMGA-Pro
EMGA-Pro

산소/질소/수소 분석기

EMIA-Expert
EMIA-Expert

탄소/황 분석기

EMIA-Pro
EMIA-Pro

탄소/유황 분석기

EMIA-Step
EMIA-Step

탄소/황 분석기 (인덕션 퍼니스 타입)

ENDA-7000 Series
ENDA-7000 Series

굴뚝 배출가스 분석장치

IR-200
IR-200

Gas Monitor for Chamber Cleaning End Point Monitoring

IR-400
IR-400

High-grade type Gas Monitor for Chamber Cleaning End Point Monitoring

LO-300
LO-300

레이저 스캔 오일 필름 검출기

MEXA-ONE
MEXA-ONE

배기 가스 측정 장치

OBS-ONE GS Unit
OBS-ONE GS Unit

차량 탑재형 배기가스 측정 장치

OBS-ONE IRLAM Unit
OBS-ONE IRLAM Unit

NH3/N2O 대응용 차량 탑재형 배기가스 측정 장치

OCMA-500
OCMA-500

폐수 오일 측정기

OCMA-550
OCMA-550

오일 농도 측정기