HE-300C

현장 설치형 전기전도도계 (2-Wire Transmission, 저농도용)

HE-300C는 전도도 센서(ESH/FS Series)를 연결하여 시료수의 전도도 및 온도를 측정합니다.
품질 지침에 따라 순수/보일러 배수 회수 제어 및 제약 용수 전도도 측정, 모니터링하는 데 적합 합니다.

- 측정 범위(전도도) : 0 ~ 2000μs/cm, 0 ~ 200.0ms/cm
                                  (TDS 환산 0 - 2000 mg/L)
- 온도 : 0 ~ 100℃

Division: Process Water
Manufacturing Company: HORIBA Advanced Techno Co., Ltd.

Tough

  • Responds to harsh conditions at the site process
      Operating temperature range(Transmitter):-20 - 60℃
      Rated voltage: DC24V
      Robust aluminum die cast (Protection code:IP65)
  • CE Marking and FCC Compliance suitable for use at overseas sites

 

Intelligence

  • Convenient function to display liquid temperature at the same time(Transmission output available)
  • Sensor error can be detected immediately by self-diagnosis function
  • Designed to be environmentally friendly (Pb-free) in response to WEEE and RoHS
  • Flexible temperature compensation

 

Easy maintenance

  • Easy to view big display
  • Easy operation
  • Calibration log memory
  • Screw terminals that do not fall off are used in the terminal block for wiring
Product nameConductivity meter
ModelHE-300C
Sensors in combination2-electrode method conductivity sensor
ESH and FS Series sensor of cell constant 0.01/cm, 0.1/cm, or 1.0/cm
Measurable
range
(*Note 1)
Cell constant (/cm)0.01
(ESH-001)
0.1
(ESH/FS-01)
1.0
(ESH-1)
 Unit
ConductivityμS/cm0.000 to 2.000
0.00 to 10.00
0.000 to 2.000
0.00 to 20.00
0.0 to 100.0
0.0 to 200.0
0 to 1000
mS/m0.0000 to 0.2000
0.000 to 1.000
0.0000 to 0.2000
0.000 to 2.000
0.00 to 10.00
0.00 to 20.00
0.0 to 100.0
TDS
conversion
mg/L0.00 to 2.00
0.0 to 10.0
0.00 to 2.00
0.0 to 20.0
0 to 100
0 to 200
0 to 1000
Temperature0 to 100 (display range: −10℃ to 160℃)
Display
resolution
Conductivity
/ TDS conversion
As shown in the measuring table.
Temperature0.01℃
PerformanceConductivityRepeatabilityWithin ±0.5% of the full scale (response for equivalent input)
Within ±5% of the full scale in the range of 2000 μS/cm or 200 mS/m for FS-01 sensor
LinearityWithin ±0.5% of the full scale (response for equivalent input)
Within ±5% of the full scale in the range of 2000 μS/cm or 200 mS/m for FS-01 sensor
TDS conversionRepeatabilityWithin ±1.5% of full-scale value (response for equivalent input)
LinearityWithin ±1.5% of full-scale value (response for equivalent input)
TemperatureRepeatability±0.1℃(response for equivalent input)
Linearity±0.5℃(response for equivalent input)
Transmission
output
Output type4 mA to 20 mA DC input/output insulation type (two-wire transmission type)
Load resistanceMaximum: 600 Ω. Case of 24 V DC power supply (*Note 3)
LinearityWithin ±0.08 mA (output only)
RepeatabilityWithin ±0.02 mA (output only)
Output rangeConductivity: Free setting within a measuring range.
Occasional out for errorHold or burnout to either 3.8 mA or 21 mA
Transmission holdIn the maintenance mode, transmission signal is held at the latest value or preset value.
In the calibration mode, transmission signal can be alive or held.
Contact
input
Number of input points1
Contact typeNo-voltage a-contact
ConditionsON resistance: 40 Ω max.
Open voltage: 1.2 VDC
Short-circuit current: 21 mA DC max.
Contact functionExternal input for transmission holding.
Temperature
compensation
Temperature elementPlatinum resistor: 1 kΩ (0℃)
Temperature compensation
  • Temperature characteristic of NaCl (reference temperature: 5℃ to 95℃)
  • Arbitrary temperature coefficient input (reference temperature: 5℃ to 95℃; temperature coefficient: ±3%/℃)
  • No temperature compensation
    One of the three ways of compensation is selectable.
    (In the de-ionized water area, the temperature compensation for pure water is automatically performed in both NaCl and arbitrary temperature coefficient compensation settings.)
Temperature compensation
range
0℃ to 100℃ (However, the compensation calculation is extended lower than 0℃ or higher than 100℃.)
Temperature calibration1 point calibration comparing to reference thermometer
CalibrationConductivityBased on parameter input of coefficient for the sensor cell constant.
TDS conversionConversion by user-defined coefficient value
(TDS calculation is 0.30 to 1.00 times of sample conductivity by μS/cm.)
Self-checkSensor diagnosis errorTemperature sensor short-circuit, temperature sensor disconnection,
and out of the temperature measurement range
Meter errorCPU error, ADC error, and memory error
Operating temperature range−20℃ to 60℃ (without freeze)
Operating humidity rangeRelative humidity: 5% to 90% (without condensation)
Storage temperature−25℃ to 65℃
Power
supply
Rated voltage24 V DC (operating voltage range: 21 V to 32 V DC) (*Note 3)
Power consumption0.6 W max.
Compatible
standards
CE markingEMC directive: EN61326-1
RoHS Directive: EN50581
 Immunity
Industrial
electromagnetic
environment
Electostatic dischargeIEC61000-4-2
Electromagnetic field of radiated radio frequencyIEC61000-4-3
Electric fast transient/burstIEC61000-4-4
SurgeIEC61000-4-5
(*Note 2)
Conducted interference induced by radio frequencyIEC61000-4-6
Emission
Class A
Radiated disturbanceCICPR 11 CLASS A
Noise terminal voltageCISPR 11 CLASS A
FCC RulesPart15 CLASS A
StructureInstallationOutdoor installation type
Installation method50 Mount on 50 A pole or wall
Protection codeIP65
Case materialAluminum alloy (coated with epoxy-denatured melamine resin)
Material of fittingsSUS304
Material of hoodSUS 304 stainless steel (coated with epoxy-denatured melamine resin)
Material of windowPolycarbonate
Display elementReflective monochrome LCD
External dimensions180 (W) × 155 (H) × 115 (D) mm (excluding mounting brackets)
MassMain body: Approx. 2.8 kg; cover and mounting brackets: Approx. 1 kg

Note

  • Note 1: Only the sanitary sensor (FS-01 series) is applied.
  • Note 2: Conductivity measurement and TDS conversion measurement cannot be selected at the same time.
  • Note 3: The maximum load resistance that can be connected is decided depending on the powersupply voltage.

 

Relation between power supply voltage and load resistance

Relation between power supply voltage and load resistance

  • Note 4: When the sensor cable, the transmission cable, or the contact input cable is extended by 30 m or more, the surge test under the EMC Directive for CE marking is not applied.
  • Note 5: An arrester (spark over voltage: 400 V) is implemented for transmission output, contact input, and communication. However, use a most suitable surge absorption element on the connection lines in accordance with the ambient environment, the situation of equipment installed, and the externally connected equipment.

제품 문의

HORIBA제품의 자세한 정보를 원하시면, 아래의 양식에 내용을 입력을 부탁드립니다.

* 는 필수입력항목입니다.

Related products

CS-620F
CS-620F

광섬유형 고온 인산 농도 모니터

CS-900
CS-900

비접촉 화학물질 농도 모니터

HC-200F
HC-200F

현장설치형 불소이온측정기(4-Wire Transmission)

HC-300F
HC-300F

현장설치형 불소이온측정기(2-Wire Transmission)

HD-200
HD-200

현장설치형 용존산소측정기(4-Wire Transmission), 멤브레인형)

HD-200FL (Four-Wire Transmission, 광학식)
HD-200FL (Four-Wire Transmission, 광학식)

현장 설치형 용존 산소 측정기

HD-300
HD-300

현장설치형 용존산소측정기(2-Wire Transmission), 멤브레인 형)

HD-480
HD-480

용존산소측정기(4-Wire Transmission), 멤브레인 형)

HD-960L
HD-960L

저농도 용존 산소 모니터

HD-960LR
HD-960LR

용존 산소 농도 모니터

HE-200C
HE-200C

현장설치형 전기전도도계(4-Wire Transmission, 저농도용)

HE-200H
HE-200H

현장설치형 전기전도도계(4-Wire Transmission, 고농도용)

HE-200R
HE-200R

현장 설치형 전기저항계(4-Wire Transmission)

HE-300C
HE-300C

현장 설치형 전기전도도계 (2-Wire Transmission, 저농도용)

HE-300C-IS ( 방폭형 )
HE-300C-IS ( 방폭형 )

방폭형 설치 타입 COND meter ( Low concentrtion )

HE-300R
HE-300R

현장 설치형 전기저항계(2-Wire Transmission)

HE-480C
HE-480C

패널 장착형 전도도계(4-Wire Transmission, 저농도용)

HE-480C-GC
HE-480C-GC

카본 센서 전도도계 (저농도형)

HE-480H
HE-480H

패널 장착형 전도도계(4-Wire Transmission,저농도용)

HE-480H-DC24V
HE-480H-DC24V

판넬 장착형 전도도계(4-wire Transmitter , 고전도도용)

HE-480R
HE-480R

패널 장착형 저항계(4-Wire Transmission)

HE-960CA
HE-960CA

구연산 모니터

HE-960CW
HE-960CW

패널 장착형 전도도계(4-Wire Transmission, 2채널)

HE-960H-KOH
HE-960H-KOH

KOH 모니터

HE-960H-TM-S
HE-960H-TM-S

고정밀 TMAH 농도 모니터

HE-960HC
HE-960HC

카본 센서 전도도계 (고농도형)

HE-960HI
HE-960HI

패널 장착형 전도도계(4-Wire Transmission, 광역용)

HE-960LC
HE-960LC

카본 센서 전도도계

HE-960LF / FS-09F-1/2
HE-960LF / FS-09F-1/2

평탄 카본 센서 전도도계

HE-960RW
HE-960RW

패널 장착형 저항계(4-Wire Transmission, 2채널)

HE-960RW-GC(W)
HE-960RW-GC(W)

2-채널 저항률계

HF-960EM
HF-960EM

인라인 센서 및 자동 범위 전환 농도 모니터

HO-480
HO-480

패널 장착형 ORP 미터 (4-Wire Transmission)

HP-200 (Four-Wire Transmission)
HP-200 (Four-Wire Transmission)

현장 설치형 pH Meter

HP-300
HP-300

현장 설치형 pH미터 (2-Wire Transmission)

HP-480
HP-480

패널 장착형 pH미터 (4-Wire Transmission)

HP-480PL
HP-480PL

패널 장착형 pH 미터(4-Wire Transmission, 펄스 비례 제어)

HP-480TP
HP-480TP

패널 장착형 pH 미터(4-Wire Transmission, 산업용 시분할 비례제어)

HP-960FTP
HP-960FTP

패널 장착형 pH 미터(4-Wire Transmission, 4 포인트 알람, 시분할 비례 제어)

HR-200
HR-200

현장 설치형 잔류염소 측정기 (4-Wire Transmission, Water flow beads)

HR-200RT
HR-200RT

현장 설치형 잔류 염소 측정기 (4-Wire Transmission, Rotating Type)

HR-480
HR-480

잔류 염소 측정기 (4-Wire Transmission)

IT-470F-H
IT-470F-H

빌트인 타입 적외선 온도계

IT-545 Series
IT-545 Series

고정밀 적외선 온도계 (휴대용)

LAQUA PH210
LAQUA PH210

Handheld pH/ORP/Temperature Meter

TW-100
TW-100

자동 수질 측정장치

TW-150
TW-150

Online Water Quality Monitor (공정 수질 측정 시스템)

U-50 Series
U-50 Series

다항목 수질 측정기

UP-100
UP-100

마이크로 볼륨 pH 모니터

HD-200
HD-200

현장설치형 용존산소측정기(4-Wire Transmission), 멤브레인형)

HD-300
HD-300

현장설치형 용존산소측정기(2-Wire Transmission), 멤브레인 형)

HD-480
HD-480

용존산소측정기(4-Wire Transmission), 멤브레인 형)

HD-960L
HD-960L

저농도 용존 산소 모니터

HD-960LR
HD-960LR

용존 산소 농도 모니터

HE-200C
HE-200C

현장설치형 전기전도도계(4-Wire Transmission, 저농도용)

HE-200H
HE-200H

현장설치형 전기전도도계(4-Wire Transmission, 고농도용)

HE-200R
HE-200R

현장 설치형 전기저항계(4-Wire Transmission)

HE-300C
HE-300C

현장 설치형 전기전도도계 (2-Wire Transmission, 저농도용)

HE-300C-IS ( 방폭형 )
HE-300C-IS ( 방폭형 )

방폭형 설치 타입 COND meter ( Low concentrtion )

HE-300R
HE-300R

현장 설치형 전기저항계(2-Wire Transmission)

HE-480C
HE-480C

패널 장착형 전도도계(4-Wire Transmission, 저농도용)

HE-480C-GC
HE-480C-GC

카본 센서 전도도계 (저농도형)

HE-480H
HE-480H

패널 장착형 전도도계(4-Wire Transmission,저농도용)

HE-480H-DC24V
HE-480H-DC24V

판넬 장착형 전도도계(4-wire Transmitter , 고전도도용)

HE-480R
HE-480R

패널 장착형 저항계(4-Wire Transmission)

HE-960CA
HE-960CA

구연산 모니터

HE-960CW
HE-960CW

패널 장착형 전도도계(4-Wire Transmission, 2채널)

HE-960H-KOH
HE-960H-KOH

KOH 모니터

HE-960H-TM-S
HE-960H-TM-S

고정밀 TMAH 농도 모니터

HE-960HC
HE-960HC

카본 센서 전도도계 (고농도형)

HE-960HI
HE-960HI

패널 장착형 전도도계(4-Wire Transmission, 광역용)

HE-960LC
HE-960LC

카본 센서 전도도계

HE-960LF / FS-09F-1/2
HE-960LF / FS-09F-1/2

평탄 카본 센서 전도도계

HE-960RW
HE-960RW

패널 장착형 저항계(4-Wire Transmission, 2채널)

HE-960RW-GC(W)
HE-960RW-GC(W)

2-채널 저항률계

HF-700A
HF-700A

황산/과산화수소 모니터 (저농도)

HF-SP-CU
HF-SP-CU

2-채널 고정밀 HF 농도 모니터

HO-480
HO-480

패널 장착형 ORP 미터 (4-Wire Transmission)

HR-200
HR-200

현장 설치형 잔류염소 측정기 (4-Wire Transmission, Water flow beads)

HR-200RT
HR-200RT

현장 설치형 잔류 염소 측정기 (4-Wire Transmission, Rotating Type)

HR-480
HR-480

잔류 염소 측정기 (4-Wire Transmission)

HT-110
HT-110

총유기탄소 모니터

HZ-960HPO-M
HZ-960HPO-M

H2O2 모니터

T1 - TOCADERO Series
T1 - TOCADERO Series

온라인 TOC 분석기

TW-100
TW-100

자동 수질 측정장치

TW-150
TW-150

Online Water Quality Monitor (공정 수질 측정 시스템)

U-50 Series
U-50 Series

다항목 수질 측정기