ENDA-5000 Stack Gas Analysis System
Overview
MCERTS Certified Continuous Emission Monitoring System (CEMS) with high-precision and simultaneous measurement of NOx, SO2, CO, CO2 and O2
Over 100,000 systems installed and 30 years of quality and experience. That is the base on which HORIBA's ENDA-5000 series of Continuous Emission Monitoring System for stack-gas analysis is built. These systems have a smaller footprint, and use cross-flow modulated non-dispersive infrared (NDIR) detection with a magnet-pneumatic detection method that is inherently drift-free. The ENDA-5000 series are superior Continuous Emission Monitoring systems (CEMs), fully certified to MCERTS standards, they are perfect for the difficult field of exhaust gas analysis, where measurement errors cannot be tolerated. The series features an intuitive touch panel that makes every operation available with the touch of a button. The ENDA-5000 series systems are also designed for faster, more efficient maintenance. They are ideal for a variety of uses, including monitoring steam boiler, refuse incinerator, and electric power generation plant emissions to assure pollution standards are being met.
Features
- Continuous simultaneous measurement of up to five components with one system
The ENDA-5000 series can measure up to five components, thanks to HORIBA's innovative optical technology. Measurements of up to five components can be made in any combination. - MCERTs Certifed
The ENDA-5000 Continuous Emission Monitoring System is certified to the Environment Agency’s MCERTs standard. - Correction for interference
The interference correcting sensor uses a unique filter to compensate for the influence of interference by other gases. - Better alerts and extra alerts
In addition to the alert functions available in the past, the ENDA-5000 series systems feature extra alert functions. A continuous checking process can prevent the unit from stopping due to a failure, reducing the risk of failed measurements and assuring consistent operation. - Dramatically reduced correction time for SO2
Corrections of SO2 measurements using wet base methods of the past took a great deal of time (about 15 minutes), but with the ENDA-5000 series system's dry base method, correction takes only three minutes.
Manufactured by HORIBA
Specifications
Model | ENDA-5000 | ||||||
Component | NOx | SO2 | CO | CO2 | O2*1 | ||
Measurement methods | NDIR | NDIR | NDIR | NDIR | Magneto-pneumatic detection | ||
Range*2 | Standard | 200~5000 ppm | 200~5000 ppm | 200~5000 ppm | 5~25 vol% | 10~25 vol% | |
| Optional | 100 ppm~ | 50 ppm~ | 100 ppm~ | - | - | |
Range Ratio | Within a factor of 10 | Within a factor of 10 | Within a factor of 10 | Within a factor of 5 | Within a factor of 2.5 | ||
Repeatability | Within 0.5% of full scale (with optional range, or during O2 measurement, ±1.0% of full scale) | ||||||
Linearity (indicator error) | ±1.0% of full scale | ||||||
Zero drift | ±1.0% of full scale (assuming surrounding temperature is maintained within 5 °C) | ||||||
Span drift | ±2.0% of full scale/week (assuming surrounding temperature is maintained within 5°) | ||||||
Response time*3 | Within 60 seconds (Td + T90 from equipment intake area) (sample flow 0.6 L/min.) (within 240 seconds for SO2 only) | ||||||
Overall interference frrom co-existing gases | ±2.0% of full scale/week (within standard range, with standard gas formation) | ||||||
Display | Touch panel LCD (backlight) (four usable lines) | ||||||
Environment | Temperature | -5 to 40 °C (away from direct sunlight and radiation heat )*4 | |||||
Humidity | 85% or less (no condensation) | ||||||
Vibration | 100 Hz, 0.3 m/S2 or less | ||||||
Dust | Standard environment or better | ||||||
Measuring Gas Condition | Temperature | 250 °C or lower | |||||
Dust | 0.1 g/Nm3 or less | ||||||
Standard gas composition*5 | NO: 500 ppm or less; NO2: 15 ppm or less; SO2: 1000 ppm or less; SO3: 50 ppm or less; | ||||||
Sampling method | Dry sampling using an electric cooler | ||||||
Sample gas flow | 2.5 L/min~3.0 L/min | ||||||
Sample inlet tube | Teflon tubing (Ø8/Ø6 mm) | ||||||
Sample gas pressure | ±4.9 kPa (three points selected) |
| |||||
Pressure control | Pressure control uses a regulator and cylinder; Reduced pressure sampling; Control pressure: -4.9 kPa | ||||||
Output | DC 4 to 20 mA (absolute output) (DC 0 to 16 mA/DC 0 to 1 V/DC 1 to 5V optional) Max. 12 output systems | ||||||
External output | Analysis alerts, analysis warnings, range display, corrections, conservation, purging (option) | ||||||
Correction method | Dry correction, automatic correction (correction cycle: 7 days standard, can be adjusted to between 1 and 99 days), manual correction | ||||||
Calibration gas | Zero gas | With measurement method authorization: N2, When there is no measurement method authorization: N2 or ambient air | |||||
O2 carrier gas | Ambient air | ||||||
Span gas | Gas cylinder for each component measured (when there is no measurement method authorization: O2 or ambient air can be used) | ||||||
Probe collection point filter | Flange: JIS 10K, 40 AFF; Sample probe tube length: 1000 mm; Material: SUS-316 stainless steel; | ||||||
Power supply | AC 100 V ±15 V(85 V~115 V) | ||||||
Power frequency | 50/60 Hz (switchable) | ||||||
Power consumption | About 800 VA (heated piping 30m: +1100 VA; heater in tray: +300 VA) | ||||||
Exterior dimensions/Mass | 600 (W) x 1770 (H) x 300 (D) mm (high pressure gas cylinders, 3.4 L cylinders, maximum of 3 cylinders); About 180 kg (not including cylinders) | ||||||
Materials in contract with sample gas | SUS-316 stainless steel, SUS-304 stainless steel, Teflon, polypropylene, polyethylene, | ||||||
Enclosure | Independent outdoor installation | ||||||
Color/Finish | Semi-gloss Munsell 5Y7/1 on all inner and outer surfaces |
*1: No carrier gas cylinder is required. *2: Up to two ranges are supported for each component. *3: Response time may vary depending on the sampling system composition.
*4: Support is available for -15 to 40 °C (cold-climate version) and 5 to 50 °C. *5: An NH3 scrubber is available as an option for cases where a combined gas includes NH3. SO2 measurement corrected for CH4 interference is available for cases where there is CH4 in the sample gas for SO2 measurement. CO measurement corrected for N2O interference is available for cases where there is N2O in the sample gas for CO measurement.
Brochures
ENDA-5000 Stack Gas Analysis System Brochure uploaded on 2014/6/13 (PDF:1.1MB)