EMIA-20XC

High-Concentration Carbon Analyzer

Highly Repeatable Carbon Analysis for Precise Control of High-Carbon Materials

Precise control of carbon concentration is critical in the production of tungsten carbide and other carbon-containing powders. 
The EMIA-20XC from EMIA-Expert series is designed for the precise analysis of high-carbon-content materials, delivering accurate, highly repeatable results and reliable long-term reproducibility. Its dedicated XC detection unit, optimized for high-carbon applications, minimizes the effects of atmospheric pressure and temperature fluctuations, enabling consistent measurements in a short time. The built-in switching function also enables the analysis of carbon and sulfur at low-ppm concentrations, combining high-concentration carbon analysis with versatile carbon/sulfur measurement in a single system.

Main Features

  •  RSD ≤ 0.15% and approximately 160 seconds in XC Mode

In XC Mode, the analyzer achieves a relative standard deviation (RSD) of ≤ 0.15% for high-carbon-content materials such as tungsten carbide. Results are displayed in approximately 160 seconds from measurement start.

  •  2-in-1 Cemented Carbide Carbon and Inorganic Carbon /Sulfur Determination

By switching the modes, the EMIA-20XC supports both high-concentration carbon analysis and low-concentration carbon and sulfur analysis.

  •  Optional autosampler is available.
制造商: HORIBA, Ltd.

Proprietary Technology for High-Repeatability Measurement 

  • The detection unit (XC unit), specialized for measuring high-carbon-content materials, minimizes the effects of atmospheric pressure and room temperature fluctuations, enabling high-repeatability measurements in a short time. 
  • Relative standard deviation (RSD) ≤ 0.15%, demonstrating outstanding reproducibility, for high-carbon-content materials, such as tungsten carbide.
  • Approximately 160 seconds from measurement start to results display: high-repeatability measurement mode (XC mode).


The Gas Flow

The EMIA-20XC enables switching between high-repeatability measurement of high-concentration carbon and measurement of low-concentration carbon and sulfur. 


Applications*

*Application examples are based on representative evaluations conducted with EMIA-20XC and/or EMIA-Pro/Expert. Results and repeatability depend on sample composition, homogeneity, concentration, particle size, pretreatment, calibration, and other measurement conditions. The specified RSD  0.15% applies only under the specified measurement conditions and is not guaranteed for all sample types. Please contact HORIBA before purchase to confirm the feasibility of your application and recommended measurement conditions.

 

 

EMIA-Expert series: EMIA-20XC Specifications by Operating Mode
 XC ModeStandard Mode
Measurement PrincipleHigh-frequency induction furnace combustion – infrared absorption method
Sample MassMax 0.50 or less than 0.49 ± 0.01 gLess than 1.00 ± 0.10 g
Measurement Time (Average)Approx. 160 secondsApprox. 60 seconds
CarbonMeasurement Range *21.0% - 20.0%0.6 ppm - 10.0%
Reproducibility *3

RSD ≤ 0.15%

σ ≤ 0.3 ppm (Sample less than 20 ppm),
σ ≤ 1 ppm or RSD ≤ 0.5% (Sample more than 20 ppm)
SulfurMeasurement Range *2-0.6 ppm - 1.0%
Reproducibility *3-σ ≤ 0.3 ppm (Sample less than 20 ppm),
σ ≤ 1 ppm or RSD ≤ 0.75% (Sample more than 20 ppm)

Utility

Carrier GasOxygen (Purity: 99.5% or higher, 0.30 - 0.33 MPa)
Operation GasNitrogen (Purity: 99.5% or higher, 0.40 - 0.45 MPa)

Dimensions (W x D x H mm) and Mass (kg)

Main Unit500 x 725 x 710 mm/approx. 134 kg*4
Purifier/Oxidizer160 x 560 x 512 mm/approx. 28 kg
XC Unit260 x 560 x 513 mm/approx. 37 kg

*1 Varies depending on the sample, measurement conditions, and options.
*2 Maximum range is extended by reducing the sample mass.
*3 Guaranteed values apply and are limited to the following conditions: When using reliable standards and using official consumables (accelerators, crucible, reagents, others).
*4 Excludes protrusions on the rear panel.

Available Options

  • Auto Sampler

Up to 20 samples can be loaded. The system automatically places crucibles in the furnace and disposes of them after measurements. Measurements can also be manually interrupted when necessary. 

 

 

  • Halogen Trap Unit

HT-03 Traps halogen derived from sample, allowing analysis with minimized influence.can be loaded. The system automatically places crucibles in the furnace and disposes of them after measurements. 

 


留言咨询

如您有任何疑问,请在此留下详细需求信息,我们将竭诚为您服务。

* 这些字段为必填项。

更多推荐

EMIA-Expert
EMIA-Expert

碳硫分析仪

EMIA-Pro
EMIA-Pro

碳硫分析仪

EMIA-Step
EMIA-Step

碳硫分析仪

51 系列
51 系列

防爆气体分析仪

AP-370 系列
AP-370 系列

空气污染监测仪

AP-380 系列
AP-380 系列

空气质量监测仪

APCA-370
APCA-370

大气污染监测用二氧化碳监测仪

APMA-370
APMA-370

大气污染监测用一氧化碳监测仪

BE-150
BE-150

CO/HC检测平台

BE-220
BE-220

NO检测平台

CCEVA
CCEVA

Carbon Capture Evaluation System

EMGA-Expert
EMGA-Expert

氧氮氢分析仪

EMGA-Expert (EMGA-21E)
EMGA-Expert (EMGA-21E)

氢分析仪 EMGA 系列(旗舰高精度型号)

EMGA-Pro
EMGA-Pro

氧氮氢分析仪

EMIA-Expert
EMIA-Expert

碳硫分析仪

EMIA-Pro
EMIA-Pro

碳硫分析仪

EMIA-Step
EMIA-Step

碳硫分析仪

ENDA-600ZG
ENDA-600ZG

烟气监测系统

ENDA-7000 Series
ENDA-7000 Series

Stack Gas Analyzer

GA-370
GA-370

痕量气体分析仪

GI-700 系列
GI-700 系列

烟气分析仪

IR-300
IR-300

蒸汽浓度监测仪

IR-400
IR-400

用于腔室清洗终点监测的高级气体监测仪

IT-470F-H
IT-470F-H

高精度红外温度计[内置式]

LO-300
LO-300

油膜检测仪

MEXA-1300R
MEXA-1300R

发动机尾气分析系统

MEXA-584L
MEXA-584L

汽车尾气排放分析仪

MEXA-ONE
MEXA-ONE

整车排放气体分析仪

OBS-ONE GS Unit
OBS-ONE GS Unit

车载排放测量系统

OCMA-500
OCMA-500

油分分析仪

OCMA-550
OCMA-550

油分分析仪

PG-300 系列
PG-300 系列

便携式气体分析仪

TCA-5000
TCA-5000

通用型氢气分析仪

TX-100
TX-100

可调谐激光气体分析仪

VA-5000 / VA-5000WM 系列
VA-5000 / VA-5000WM 系列

多组分气体分析仪

Corporate